REAL-TIME MONITORING AND ANALYSIS OF ATHLETE MUSCLE ACTIVITY BASED ON WEARABLE SENSOR

被引:0
作者
Han, Jilei [1 ]
机构
[1] Xi An Jiao Tong Univ, Ctr Phys Educ, Xian 710049, Shaanxi, Peoples R China
来源
REVISTA INTERNACIONAL DE MEDICINA Y CIENCIAS DE LA ACTIVIDAD FISICA Y DEL DEPORTE | 2024年 / 24卷 / 95期
关键词
Real-Time; Muscle Activity; Wearable Sensors; NEAR-INFRARED SPECTROSCOPY; ELECTROMYOGRAPHY; OXYGENATION; ACTIVATION; EXERCISE; NIRS;
D O I
10.15366/rimcafd2024.95.026
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Muscle fatigue is a common phenomenon in life and work, which reduces work efficiency and quality of life, and also affects the performance of the biomechanical interface. It is of great research value to collect and analyze the information related to muscle contraction to study the mechanism of muscle fatigue. In order to better study the athlete muscle contraction movement, the principle of photoelectric volumetric tracing (PPG) to detect the athlete muscle contraction movement is introduced, and a reflective photoelectric muscle contraction sensing system that can detect four signals at the same time is designed. A programmable constant -current source is used to drive an infrared LED to irradiate infrared light into the muscle tissue, and the light transmitted out of the muscle is detected by another infrared detection circuit and converted into an electrical signal. Under the control of the microcontroller, the four detected electrical signals are time -conducted by analog multi -switches, followed by low-pass filtering and AD sampling, and finally the obtained four data are transmitted to the upper computer through the Bluetooth module for subsequent processing. The circuit realizes the synchronous detection function of 4 -channel signals, and the system is accurate, reliable and has certain practical value.
引用
收藏
页码:419 / 437
页数:19
相关论文
共 19 条
[1]   NIRS monitoring of muscle contraction to control a prosthetic device [J].
Bianchi, T ;
Zambarbieri, D ;
Beltrami, G ;
Verni, G .
BIOMEDICAL SENSORS, FIBERS, AND OPTICAL DELIVERY SYSTEMS, PROCEEDINGS, 1999, 3570 :157-163
[2]   The impact of pedal rate on muscle oxygenation, muscle activation and whole-body VO2 during ramp exercise in healthy subjects [J].
Boone, Jan ;
Barstow, Thomas J. ;
Celie, Bert ;
Prieur, Fabrice ;
Bourgois, Jan .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2015, 115 (01) :57-70
[3]   Near-infrared spectroscopy as a tool for in vivo analysis of human muscles [J].
Curra, Antonio ;
Gasbarrone, Riccardo ;
Cardillo, Alessandra ;
Trompetto, Carlo ;
Fattapposta, Francesco ;
Pierelli, Francesco ;
Missori, Paolo ;
Bonifazi, Giuseppe ;
Serranti, Silvia .
SCIENTIFIC REPORTS, 2019, 9 (1)
[4]   Quantification in tissue near-infrared spectroscopy [J].
Delpy, DT ;
Cope, M .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1997, 352 (1354) :649-659
[5]  
Feng Y., 2014, Electronic Device, V37, P830
[6]   A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of application [J].
Ferrari, Marco ;
Quaresima, Valentina .
NEUROIMAGE, 2012, 63 (02) :921-935
[7]   Novel muscle activation sensors for estimating of upper limb motion intention [J].
Han, Hyonyoung ;
Kim, Jung .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :3767-3770
[8]   Motion artifact reduction in photoplethysmography using independent component analysis [J].
Kim, BS ;
Yoo, SK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) :566-568
[9]   Fatigue sensation, electromyographical and hemodynamic changes of low back muscles during repeated static contraction [J].
Movahed, Mehrnoosh ;
Ohashi, Jun-ya ;
Kurustien, Nopporn ;
Izumi, Hiroyuki ;
Kumashiro, Masaharu .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (03) :459-467
[10]   Muscle oxygen consumption, determined by NIRS, in relation to external force and EMG [J].
Praagman, M ;
Veeger, HEJ ;
Chadwick, EKJ ;
Colier, WNJM ;
van der Helm, FCT .
JOURNAL OF BIOMECHANICS, 2003, 36 (07) :905-912