Scotopic and Photopic Conventional Visual Acuity and Hyperacuity - Binocular Summation

被引:0
作者
Korn, Sophie [1 ]
Al-Nosairy, Khaldoon O. [1 ]
Gopiswaminathan, Akshara, V [1 ]
Joao, Catarina [2 ]
Scanferla, Lorenzo [2 ]
Bach, Michael [4 ]
Hoffmann, Michael B. [1 ,3 ,5 ,6 ]
机构
[1] Otto Von Guericke Univ, Dept Ophthalmol, Magdeburg, Germany
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Ophthalmol, Groningen, Netherlands
[3] Univ Groningen, Grad Sch Med Sci, Res Sch Behav & Cognit Neurosci, Groningen, Netherlands
[4] Univ Freiburg, Fac Med, Eye Ctr, Freiburg, Germany
[5] Ctr Behav Brain Sci, Magdeburg, Germany
[6] Univ Augenklin, Visual Proc Lab, Leipziger Str 44, D-39120 Magdeburg, Germany
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2024年 / 13卷 / 04期
关键词
binocular summation; (BiS); visual acuity (VA); hyperacuity; photopic VA; scotopic VA; psychophysics; CONTRAST SENSITIVITY; VORETIGENE NEPARVOVEC; VERNIER ACUITY; VISION; RESOLUTION;
D O I
10.1167/tvst.13.4.25
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:The purpose of this study was to determine and compare binocularsummation (BiS) of conventional visual acuity (cVA) versus hyperacuity (hVA) forphotopic and scotopic luminance conditions as a potential biomarker to assess theoutcome of interventions on binocular function.<br /> Methods: Sixteen young adults (age range [years] = 21-31; 8 women; cVA logMAR < 0.0) participated in this study. The Freiburg Visual Acuity Test (FrACT) was used for VA testing and retested on another day. Both cVA and hVA were determined for dark grey optotypes on light grey background. Participants underwent 40 minutes of dark adaptation prior to scotopic VA testing. Binocular and monocular VA testing was performed. The eye with better VA over the 2 days of testing was selected, the BiS was quantified (binocular VA - better monocular VA) and repeated measures ANOVAs were performed.<br /> Results: Binocular VA exceeded monocular VA for all luminance conditions, VA-types, and sessions. We report BiS estimates for photopic and scotopic cVA and hVA, (logMAR BiS +/- SEM [decimal BiS]): photopic = -0.01 +/- 0.01 [1.03] and -0.06 +/- 0.03 [1.15]; and scotopic = -0.05 +/- 0.01 [1.12] and -0.11 +/- 0.04 [1.28], respectively). Improvement for binocular vision estimates ranged from 0.01 to 0.11 logMAR. A repeated-measures ANOVA (RM ANOVA) did not reveal significant effects of LUMINANCE or VA TYPE on BiS, albeit a trend for strongest BiS for scotopic hVA (15% vs. 28%, photopic versus scotopic, respectively) and weakest for photopic cVA (3% vs. 12%, photopic versus scotopic conditions, respectively).<br /> Conclusions: Our results indicate that BiS of VA is relevant to scotopic and photopic hVA and cVA. It appears therefore a plausible candidate biomarker to assess the outcome of retinal therapies restoring rod or cone function on binocular vision.
引用
收藏
页数:10
相关论文
共 42 条
  • [21] Binocular summation and visual function with induced anisocoria and monovision
    Castro, Jose J.
    Soler, Margarita
    Ortiz, Carolina
    Jimenez, Jose R.
    Anera, Rosario G.
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (10): : 4250 - 4262
  • [22] BINOCULAR SUMMATION AND THE BINOCULARITY OF CAT VISUAL-CORTEX
    GRUNAU, MV
    VISION RESEARCH, 1979, 19 (07) : 813 - 816
  • [23] Evaluation of visual evoked potential binocular summation after corneal refractive surgery
    Amini Vishteh, Rasoul
    Mirzajani, Ali
    Jafarzadehpur, Ebrahim
    Taghieh, Abolghasem
    DOCUMENTA OPHTHALMOLOGICA, 2020, 140 (02) : 181 - 188
  • [24] TONIC INTEROCULAR SUPPRESSION, BINOCULAR SUMMATION, AND THE VISUAL-EVOKED POTENTIAL
    EYSTEINSSON, T
    BARRIS, MC
    DENNY, N
    FRUMKES, TE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (08) : 2443 - 2448
  • [25] A comparison of binocular summation in the peripheral visual field in young and older patients
    Pardhan, S
    CURRENT EYE RESEARCH, 1997, 16 (03) : 252 - 255
  • [26] Binocular recognition summation in the peripheral visual field: contrast and orientation dependence
    Pardhan, S
    VISION RESEARCH, 2003, 43 (11) : 1249 - 1255
  • [27] Binocular Dynamic Visual Acuity in Eyeglass-corrected Myopic Patients
    Wang, Yuexin
    Guo, Yining
    Wei, Shanshan
    Yuan, Yifei
    Wu, Tingyi
    Zhang, Yu
    Chen, Yueguo
    Li, Xuemin
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (181):
  • [28] The impact of different corneal refractive surgeries on binocular dynamic visual acuity
    Wang, Yuexin
    Guo, Yining
    Li, Yuanting
    Zhang, Yu
    Yuan, Yifei
    Wu, Tingyi
    Chen, Yueguo
    Li, Xuemin
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [29] Maturation of Binocular, Monocular Grating Acuity and of the Visual Interocular Difference in the First 2 Years of Life
    Costa, Marcelo Fernandes
    Rodrigues Matos Franca, Valtenice de Cassia
    Salgueiro Barboni, Mirella Teles
    Ventura, Dora Fix
    CLINICAL EEG AND NEUROSCIENCE, 2018, 49 (03) : 159 - 170
  • [30] Binocular visual acuity for the correction of spherical aberration in polychromatic and monochromatic light
    Schwarz, Christina
    Canovas, Carmen
    Manzanera, Silvestre
    Weeber, Henk
    Prieto, Pedro M.
    Piers, Patricia
    Artal, Pablo
    JOURNAL OF VISION, 2014, 14 (02): : 1 - 11