Comparison Between Intraoperative Target Area Cement-Enhanced Percutaneous Vertebroplasty and Conventional Percutaneous Vertebroplasty for Osteoporotic Thoracolumbar Non-Total Vertebral Fractures

被引:0
作者
Wang, Yunqing [1 ]
Zhou, Chengqiang [2 ]
Liao, Yifeng [2 ]
Meng, Xiao [2 ]
机构
[1] Xuzhou Med Univ, Dept Orthoped, Affiliated Hosp 2, Xuzhou 221000, Jiangsu, Peoples R China
[2] Xuzhou Med Univ, Grad Sch, Xuzhou 221000, Jiangsu, Peoples R China
关键词
Elderly; Incomplete Vertebra fracture; Innovation; Kyphoplasty; Minimally invasive; Osteoporosis; Precision; Percutaneous vertebroplasty; Targeted cement; Thoracolumbar; COMPRESSION FRACTURES; BALLOON KYPHOPLASTY; VOLUME; RECOMPRESSION; BODY;
D O I
10.5137/1019-5149.JTN.43749-23.2
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
AIM: To compare the efficacy and feasibility of target area cement -enhanced percutaneous vertebroplasty (PVP) and conventional PVP in osteoporotic thoracolumbar non -total vertebral fractures. MATERIAL and METHODS: Retrospective analysis of one hundred and two patients treated in our hospital from March 2020 to May 2021 and divided into groups A (targeted) and B (conventional PVP). The Visual Analogue Scale (VAS), Oswestry Disability Index (ODI), anterior vertebral height ratio, intraoperative bleeding, operative time, bone cement volume, complications, and refracture of the injured vertebra were evaluated in both groups. RESULTS: The 2 days and 1 -year post -operative VAS and ODI scores improved significantly in both groups (p<0.05). The 2 days post -operative VAS and ODI scores were better in group A (p<0.05), and there was no significant difference in the scores between the groups at the last follow-up (p>0.05). The anterior vertebral height ratios were significantly higher in both groups 2 days postoperatively (p<0.05); however, there was no significant difference in the 2 days and 1 -year post -operative ratios in group A (p>0.05). The anterior vertebral height ratio reduced in group B after 1 year compared to the 2 days post -operative value (p<0.05). There was no statistical difference in intraoperative bleeding and the operative time between the groups (p>0.05), and the bone cement volume was lesser in group A (p<0.05). Six patients in group A and four patients in group B demonstrated cement leakage, the difference was not statistically significant (p>0.05). Three patients in group A and 11 patients in group B demonstrated refracture, the difference was statistically significant (p<0.05). CONCLUSION: Target area cement -enhanced PVP can effectively relieve short-term pain and functional disability and reduce the long-term possibility of secondary collapse. Therefore, it is a technically feasible and efficacious method for the treatment of osteoporotic thoracolumbar non -total vertebral fractures.
引用
收藏
页码:461 / 467
页数:7
相关论文
共 23 条
[1]   The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1537-1541
[2]   Kirschner wire-guided technique for inserting a second needle into inadequately filled vertebrae in vertebroplasty: a technical report [J].
Chen, Yen-Jen ;
Chen, Hui-Yi ;
Lo, Da-Fu ;
Chen, Hsien-Te ;
Hsu, Horng-Chaung .
SPINE JOURNAL, 2014, 14 (12) :3025-3029
[3]   Cement distribution, volume, and compliance in vertebroplasty - Some answers from an anatomy-based nonlinear finite element study [J].
Chevalier, Yan ;
Pahr, Dieter ;
Charlebois, Mathieu ;
Heini, Paul ;
Schneider, Erich ;
Zysset, Philippe .
SPINE, 2008, 33 (16) :1722-1730
[4]   Is There a Dose-Response Relationship of Cement Volume With Cement Leakage and Pain Relief After Vertebroplasty? [J].
Fu, Zhiyi ;
Hu, Xiaopeng ;
Wu, Yujie ;
Zhou, Zihui .
DOSE-RESPONSE, 2016, 14 (04)
[5]  
Ji CY, 2021, PAIN PHYSICIAN, V24, pE335
[6]   Does balloon kyphoplasty improve the global spinal alignment in osteoporotic vertebral fracture? [J].
Kanayama, Masahiro ;
Oha, Fumihiro ;
Iwata, Akira ;
Hashimoto, Tomoyuki .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) :1137-1143
[7]  
Kaufmann TJ, 2006, AM J NEURORADIOL, V27, P1933
[8]   Delayed Height Loss After Kyphoplasty in Osteoporotic Vertebral Fracture with Severe Collapse: Comparison with Vertebroplasty [J].
Kim, Sang-Il ;
Ha, Kee-Yong ;
Cho, Yong-Soo ;
Kim, Ki-Won ;
Oh, In-Soo .
WORLD NEUROSURGERY, 2018, 119 :E580-E588
[9]   Recompression of vertebral body after balloon kyphoplasty for osteoporotic vertebral compression fracture [J].
Kim, Young-Yul ;
Rhyu, Kee-Won .
EUROPEAN SPINE JOURNAL, 2010, 19 (11) :1907-1912
[10]   Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: a three-dimensional finite element analysis [J].
Liang, De ;
Ye, Lin-Qiang ;
Jiang, Xiao-Bing ;
Yang, Pan ;
Zhou, Guang-Quan ;
Yao, Zhen-Song ;
Zhang, Shun-Cong ;
Yang, Zhi-Dong .
JOURNAL OF SURGICAL RESEARCH, 2015, 195 (01) :246-256