Clearances Assessment in the Volkswagen Crafter Chassis by Means of the 3D Scan

被引:0
|
作者
Mura, Francesco Dalle [1 ]
Puggelli, Luca [1 ]
Furferi, Rocco [1 ]
Governi, Lapo [1 ]
机构
[1] Univ Florence, Dept Ind Engn, Via Santa Marta 3, I-50139 Florence, Italy
来源
DESIGN TOOLS AND METHODS IN INDUSTRIAL ENGINEERING III, VOL 2, ADM 2023 | 2024年
关键词
Tolerance Stack-ups; 3D scanning; CAD model; Reverse Engineering; Deviation Analysis; TOLERANCE ANALYSIS;
D O I
10.1007/978-3-031-58094-9_46
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In mechanical design, tolerance stack-up has a fundamental role to ensure mechanical coupling among assembly components. To avoid interferences, gaps between connected parts are introduced since the design phase, to compensate for possible dimensional variations. The present study aims to assess clearances in the Volkswagen Crafter chassis, by comparing the CAD model to the 3D reconstruction of the real van, obtained by means of 3D scanning. This activity has been carried out within SMART AMBULANCE project (POR FESR Toscana call), which has as its goal the realization of an advanced ambulance by implying smart technologies. Clearance analysis was performed before proceeding with the design of the interior setup of the ambulance medical compartment, since even small deviations may compromise the assembly of the covering panels. The analysis was useful not only to evaluate deviations between ideal and real geometry, but also to identify the locations of the gaps.
引用
收藏
页码:418 / 426
页数:9
相关论文
共 50 条
  • [31] 3D virtual endoscopy of the upper airway: Optimization of the scan parameters in a cadaver phantom and clinical assessment
    Rodenwaldt, J
    Kopka, L
    Roedel, R
    Margas, A
    Grabbe, E
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) : 405 - 411
  • [32] Efficiently registering scan point clouds of 3D printed parts for shape accuracy assessment and modeling
    Decker, Nathan
    Wang, Yuanxiang
    Huang, Qiang
    JOURNAL OF MANUFACTURING SYSTEMS, 2020, 56 : 587 - 597
  • [33] Assessment of the isostatic state and the load distribution of the European Molasse basin by means of lithospheric-scale 3D structural and 3D gravity modelling
    Przybycin, Anna M.
    Scheck-Wenderoth, Magdalena
    Schneider, Michael
    INTERNATIONAL JOURNAL OF EARTH SCIENCES, 2015, 104 (05) : 1405 - 1424
  • [34] Assessment of the isostatic state and the load distribution of the European Molasse basin by means of lithospheric-scale 3D structural and 3D gravity modelling
    Anna M. Przybycin
    Magdalena Scheck-Wenderoth
    Michael Schneider
    International Journal of Earth Sciences, 2015, 104 : 1405 - 1424
  • [35] Optimal 3D reconstruction of coronary arteries for 3D clinical assessment
    Fallavollita, Pascal
    Cheriet, Farida
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (06) : 476 - 487
  • [36] 3D Human Body Scan Data Segmentation and Application
    Gao, Cheng-Ying
    Liu, Ning
    TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2009, : 683 - 685
  • [37] An overlapped scan method for enhanced 3D radome characterization
    Barnes, W. J.
    Yeary, M.
    Olivero, K.
    Phillips, J.
    Ibrahim, T.
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 531 - +
  • [38] Registration of 3D scan data using image reprojection
    Byun, Sungho
    Jung, Keonhwa
    Im, Sungbin
    Chang, Minho
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2017, 18 (09) : 1221 - 1229
  • [39] Implications of Emerging 3D GPU Architecture on the Scan Primitive
    Power, Jason
    Li, Yinan
    Hill, Mark D.
    Patel, Jignesh M.
    Wood, David A.
    SIGMOD RECORD, 2015, 44 (01) : 18 - 23
  • [40] Fit analysis using live and 3D scan models
    Bye, Elizabeth
    McKinney, Ellen
    INTERNATIONAL JOURNAL OF CLOTHING SCIENCE AND TECHNOLOGY, 2010, 22 (2-3) : 88 - 100