Diastolic function assessment with four-dimensional flow cardiovascular magnetic resonance using automatic deep learning E/A ratio analysis

被引:2
|
作者
Viola, Federica [1 ,2 ]
Bustamante, Mariana [1 ,2 ,3 ]
Bolger, Ann [1 ,4 ]
Engvall, Jan [2 ,5 ,6 ]
Ebbers, Tino [1 ,2 ]
机构
[1] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Diagnost & Specialist Med, Linkoping, Sweden
[2] Linkoping Univ, Ctr Med Image Sci & Visualizat CM, Linkoping, Sweden
[3] deCODE Genet Amgen Inc, Reykjavik, Iceland
[4] Univ Calif San Francisco, Dept Med, San Francisco, CA USA
[5] Linkoping Univ, Dept Clin Physiol Linkoping, Linkoping, Sweden
[6] Linkoping Univ, Dept Hlth Med & Caring Sci, Linkoping, Sweden
基金
瑞典研究理事会;
关键词
4D Flow CMR; Diastolic function; EA ratio; Deep learning; AMERICAN SOCIETY; MITRAL-VALVE; GUIDELINES; ECHOCARDIOGRAPHY; QUANTIFICATION; MRI;
D O I
10.1016/j.jocmr.2024.101042
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Diastolic left ventricular (LV) dysfunction is a powerful contributor to the symptoms and prognosis of patients with heart failure. In patients with depressed LV systolic function, the E/A ratio, the ratio between the peak early (E) and the peak late (A) transmitral flow velocity, is the first step to defining the grade of diastolic dysfunction. Doppler echocardiography (echo) is the preferred imaging technique for diastolic function assessment, while cardiovascular magnetic resonance (CMR) is less established as a method. Previous four-dimensional (4D) Flow -based studies have looked at the E/A ratio proximal to the mitral valve, requiring manual interaction. In this study, we compare an automated, deep learning -based and two semi -automated approaches for 4D Flow CMR-based E/A ratio assessment to conventional, gold -standard echo -based methods. Methods: Ninety-seven subjects with chronic ischemic heart disease underwent a cardiac echo followed by CMR investigation. 4D Flow -based E/A ratio values were computed using three different approaches; two semi -automated, assessing the E/A ratio by measuring the inflow velocity (MVvel) and the inflow volume (MVflow) at the mitral valve plane, and one fully automated, creating a full LV segmentation using a deep learning -based method with which the E/A ratio could be assessed without constraint to the mitral plane (LVvel). Results: MVvel, MVflow, and LVvel E/A ratios were strongly associated with echocardiographically derived E/A ratio (R 2 = 0.60, 0.58, 0.72). LVvel peak E and A showed moderate association to Echo peak E and A, while MVvel values were weakly associated. MVvel and MVflow EA ratios were very strongly associated with LVvel (R 2 = 0.84, 0.86). MVvel peak E was moderately associated with LVvel, while peak A showed a strong association (R 2 = 0.26, 0.57). Conclusion: Peak E, peak A, and E/A ratio are integral to the assessment of diastolic dysfunction and may expand the utility of CMR studies in patients with cardiovascular disease. While underestimation of absolute peak E and A velocities was noted, the E/A ratio measured with all three 4D Flow methods was strongly associated with the gold standard Doppler echocardiography. The automatic, deep learning -based method performed best, with the most favorable runtime of similar to 40 seconds. As both semi -automatic methods associated very strongly to LVvel, they could be employed as an alternative for estimation of E/A ratio.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Four-dimensional flow cardiac magnetic resonance assessment of left ventricular diastolic function
    Ashkir, Zakariye
    Myerson, Saul
    Neubauer, Stefan
    Carlhall, Carl-Johan
    Ebbers, Tino
    Raman, Betty
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [2] Evaluation of Left Ventricular Function Using Four-Dimensional Flow Cardiovascular Magnetic Resonance: A Systematic Review
    Qin, Jiaxing Jason
    Indja, Ben
    Gholipour, Alireza
    Gok, Mustafa
    Grieve, Stuart M.
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2022, 9 (09)
  • [3] Validation of four-dimensional flow cardiovascular magnetic resonance for aortic stenosis assessment
    Archer, Gareth T.
    Elhawaz, Alaa
    Barker, Natasha
    Fidock, Benjamin
    Rothman, Alexander
    van der Geest, R. J.
    Hose, Rod
    Briffa, Norman
    Hall, Ian R.
    Grech, Ever
    Bissell, Malenka
    Al-Mohammad, Abdallah
    Treibel, Thomas A.
    Swift, Andrew J.
    Wild, James M.
    Garg, Pankaj
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [4] Four-dimensional flow cardiovascular magnetic resonance in tetralogy of Fallot: a systematic review
    Elsayed, Ayah
    Gilbert, Kathleen
    Scadeng, Miriam
    Cowan, Brett R.
    Pushparajah, Kuberan
    Young, Alistair A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [5] Quantification of regurgitation in mitral valve prolapse with four-dimensional flow cardiovascular magnetic resonance
    Spampinato, Ricardo A.
    Jahnke, Cosima
    Crelier, Gerard
    Lindemann, Frank
    Fahr, Florian
    Czaja-Ziolkowska, Monika
    Sieg, Franz
    Strotdrees, Elfriede
    Hindricks, Gerhard
    Borger, Michael A.
    Paetsch, Ingo
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [6] Four-dimensional flow magnetic resonance imaging in cirrhosis
    Zoran Stankovic
    World Journal of Gastroenterology, 2016, (01) : 89 - 102
  • [7] Quantification of regurgitation in mitral valve prolapse with four-dimensional flow cardiovascular magnetic resonance
    Ricardo A. Spampinato
    Cosima Jahnke
    Gerard Crelier
    Frank Lindemann
    Florian Fahr
    Monika Czaja-Ziolkowska
    Franz Sieg
    Elfriede Strotdrees
    Gerhard Hindricks
    Michael A. Borger
    Ingo Paetsch
    Journal of Cardiovascular Magnetic Resonance, 23
  • [8] Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: A systematic review
    Crandon, Saul
    Elbaz, Mohammed S. M.
    Westenberg, Jos J. M.
    van der Geest, Rob J.
    Plein, Sven
    Garg, Pankaj
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 249 : 486 - 493
  • [9] Four-dimensional flow magnetic resonance imaging in cirrhosis
    Stankovic, Zoran
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (01) : 89 - 102
  • [10] High Resolution Simulation of Diastolic Left Ventricular Hemodynamics Guided by Four-Dimensional Flow Magnetic Resonance Imaging Data
    Trung Bao Le
    Elbaz, Mohammed S. M.
    Van der Geest, Rob J.
    Sotiropoulos, Fotis
    FLOW TURBULENCE AND COMBUSTION, 2019, 102 (01) : 3 - 26