Impact of Particle Shape on Crushing Behaviour of Rock Particles Using X-ray Micro-CT Testing and DEM Modelling

被引:2
作者
Zhao, Xiaolong [1 ,2 ,3 ]
Wu, Yunlong [2 ]
Jia, Yun [2 ]
Bian, Hanbing [4 ]
Bur, Nicolas [2 ]
Zhu, Jungao [3 ]
Colliat, Jean-Baptiste [2 ]
机构
[1] Shandong Agr Univ, Coll Water Conservancy & Civil Engn, Tai An 271018, Peoples R China
[2] Univ Lille, UMR LaMcube Lab Mecan 9013, CNRS, Cent Lille,Multiphys,Multiechelle, F-59000 Lille, France
[3] Hohai Univ, Key Lab Geomech & Embankment Engn, Minist Educ, Nanjing 210098, Peoples R China
[4] Univ Lille, LGCgE Lab Civil Engn & Geoenvironm, ULR 4515, F-59000 Lille, France
基金
中国国家自然科学基金;
关键词
Rock particle; Grain crushing; Particle-scale behaviour; In-situ CT experiment; Discrete element modelling; WEIBULL STATISTICS; COMPRESSION; TOMOGRAPHY; STRENGTH; MICROMECHANICS; FRACTURE; SIMULATIONS; SPHERICITY; GENERATION; MECHANICS;
D O I
10.1007/s00603-024-03916-4
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Particle crushing is a fundamental issue in the analysis of the deformation and failure behaviour of rockfill materials. The impact of morphology on the crushing behaviour of granite particles is investigated via a series of in-situ X-ray micro-CT tests and DEM simulations. Single-particle crushing tests are performed on rock particles of three different sizes. During mechanical loading, four in-situ CT scans are performed on each grain using an innovative loading apparatus. The CT test images reveal that the shape of the particle and its heterogeneous structure are crucial factors in determining failure patterns. Additionally, various shape indexes of rock particles change progressively and tend to stabilize, while their fragments follow a fractal distribution, seemingly independent of their initial size. Based on CT images, numerical particles with realistic shapes and internal flaws are generated using a proposed numerical method. It is observed that an increase in elongation index EI or flatness index FI results in a decrease in characteristic strength sigma 0\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sigma _0$$\end{document} and an increase in Weibull modulus m. A novel loading apparatus has been developed for the realization of in-situ mu\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mu$$\end{document}CT scans during single-particle crushing tests.CT test images reveal that particle shape and its heterogeneous structure are crucial factors in determining the failure pattern of rockfill particles.A new numerical method is proposed for generating particles, including both particle shape and microstructure.For particle shape, increasing the elongation index and flatness index of particle results in a decrease in characteristic strength sigma 0\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sigma _0$$\end{document} and an increase in Weibull modulus .
引用
收藏
页码:7813 / 7834
页数:22
相关论文
共 50 条
  • [21] Morphology of Nonmetallic-inclusion Clusters Observed in Molten Metal by X-ray Micro-CT
    Li, Tao
    Shimasaki, Shin-ichi
    Taniguchi, Shoji
    Uesugi, Kentaro
    Narita, Shunsuke
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2015, 101 (02): : 148 - 157
  • [22] Optimisation of a propagation-based x-ray phase-contrast micro-CT system
    Nesterets, Yakov, I
    Gureyev, Timur E.
    Dimmock, Matthew R.
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2018, 51 (11)
  • [23] Fracture evolution in concrete compressive fatigue experiments based on X-ray micro-CT images
    Skarzynski, L.
    Marzec, I
    Tejchman, J.
    [J]. INTERNATIONAL JOURNAL OF FATIGUE, 2019, 122 : 256 - 272
  • [24] Modulus Modeling of PP/GF Composites by X-ray Micro-CT and Comparison with Experimental Data
    Seo, Sung Sik
    Lee, Seok Min
    Kim, Se Mi
    Park, Hee Jung
    Lee, Kee Yoon
    [J]. POLYMER-KOREA, 2019, 43 (03) : 465 - 474
  • [25] Identification of Microstructural Properties of Shale by combined Use of X-Ray Micro-CT and Nanoindentation Tests
    Cala, Marek
    Cyran, Katarzyna
    Kawa, Marek
    Kolano, Malwina
    Lydzba, Dariusz
    Pachnicz, Michal
    Rajczakowska, Magdalena
    Rozanski, Adrian
    Sobotka, Maciej
    Stefaniuk, Damian
    Stopkowicz, Agnieszka
    Walach, Daniel
    [J]. ISRM EUROPEAN ROCK MECHANICS SYMPOSIUM EUROCK 2017, 2017, 191 : 735 - 743
  • [26] An Automatic Regularization Method: An Application for 3-D X-Ray Micro-CT Reconstruction Using Sparse Data
    Purisha, Zenith
    Karhula, Sakari S.
    Ketola, Juuso H.
    Rimpelainen, Juho
    Nieminen, Miika T.
    Saarakkala, Simo
    Kroger, Heikki
    Siltanen, Samuli
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (02) : 417 - 425
  • [27] Assessing efficacy of standard impregnation techniques on die-cast aluminum alloys using X-ray micro-CT
    Bandara, Ajith
    Kan, Koichi
    Yusuke, Katanaga
    Soga, Natsuto
    Koike, Akifumi
    Aoki, Toru
    [J]. CHINA FOUNDRY, 2024, 21 (03) : 276 - 286
  • [28] Study of hydrate occupancy, morphology and microstructure evolution with hydrate dissociation in sediment matrices using X-ray micro-CT
    Wang, Daigang
    Li, Yong
    Liu, Changling
    Zhan, Linsen
    Lu, Hailong
    Li, Chengfeng
    Sun, Jianye
    Meng, Qingguo
    Liu, Lele
    [J]. MARINE AND PETROLEUM GEOLOGY, 2020, 113
  • [29] Compression deformation of a biaxial stitched glass fibre reinforcement: Visualisation and image analysis using X-ray micro-CT
    Somashekar, A. A.
    Bickerton, S.
    Bhattacharyya, D.
    [J]. COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2011, 42 (02) : 140 - 150
  • [30] Application of X-ray micro-CT for micro-structural characterization of APCVD deposited SiC coatings on graphite conduit
    Agrawal, A. K.
    Sarkar, P. S.
    Singh, B.
    Kashyap, Y. S.
    Rao, P. T.
    Sinha, A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 108 : 133 - 142