Microstructure, mechanical properties and interaction mechanism of seawater sea-sand engineered cementitious composite (SS-ECC) with Glass Fiber Reinforced Polymer (GFRP) bar

被引:11
作者
Wei, Jiaying [1 ]
Ke, Linyuwen [1 ]
Wang, Peng [1 ,2 ]
Li, Weiwen [2 ]
Leung, Christopher K. Y. [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Civil & Environm Engn, Clear Water Bay, Hong Kong, Peoples R China
[2] Shenzhen Univ, Guangdong Prov Key Lab Durabil Marine Civil Engn, Shenzhen, Peoples R China
关键词
Glass fiber reinforced polymer (GFRP); Seawater sea-sand (SS); Engineered cementitious composite (ECC); Mechanical properties; Load transfer mechanism; Pull-out test; STRAIN-HARDENING BEHAVIOR; LONG-TERM DURABILITY; HIGH-STRENGTH; COMPRESSIVE STRENGTH; CONCRETE BEAM; SILICA FUME; FLEXURAL BEHAVIORS; BOND BEHAVIOR; PERFORMANCE; BASALT;
D O I
10.1016/j.compstruct.2024.118302
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
With increasing demand for sustainable and long-lasting materials, seawater sea-sand engineered cementitious composite (SS-ECC) has emerged as a promising alternative to conventional concrete in near-ocean construction projects. Glass fiber reinforced polymer (GFRP) bar with excellent corrosion resistance is an ideal choice for these applications. This study evaluated the bond performance of GFRP bars embedded in normal-strength ECC with polyvinyl alcohol (PVA) fibers and high-strength ECC with polyethylene (PE) fibers through pull-out tests. Additionally, tests were conducted on GFRP bars in pristine ECC made with freshwater and river sand for comparison. Further investigation explored the structural properties and uncovered load transfer mechanisms. Results indicated that saline content facilitated early cement hydration of normal-strength ECC, resulting in finer pore structure (10.5% lower porosity and 12.5% lower sorptivity), slightly enhanced compressive performance (1.2% higher compressive strength and 8.3% higher elastic modulus), denser microstructure at GFRP-ECC interface (13.7% lower porous transition zone thickness, 19.2% narrower transition zone and 19.7% higher Ca/Si ratio), and superior bond performance (28.3% higher bond strength and 22.6% higher fracture energy). Conversely, saline content imposed a limited impact on the mechanical properties of high-strength ECC, primarily attributed to the ultra-fine microstructure and early strength characteristics exhibited by the silica fume (SF)-based cementitious binder.
引用
收藏
页数:20
相关论文
共 114 条
[1]  
[Anonymous], D114198 ASTM
[2]  
[Anonymous], "BS EN 206:2014. Concrete-Specification, Performance, Production and Conformity"
[3]  
[Anonymous], 2016, BS EN 196-1
[4]  
[Anonymous], "ACI 440.3R-12. Guide Test Methods for Fiber-Reinforced Polymer"
[5]  
[Anonymous], "ASTM C1585-2013. Standard Test Method for Measurement of Rate of Absorption of Water by Hydraulic-Cement Concretes".
[6]  
[Anonymous], "ASTM D4475-02. Standard Test Method for Apparent Horizontal Shear Strength of Pultruded Reinforced Plastic Rods by the Short-Beam Method".
[7]  
[Anonymous], "ASTM D4476/D4476M-14. Standard Test Method for Flexural Properties of Fiber Reinforced Pultruded Plastic Rods".
[8]  
[Anonymous], "ASTM D7205/D7205M-06. Standard Test Method for Tensile Properties of Fiber Reinforced Polymer Matrix Composite Bars".
[9]  
[Anonymous], "ASTM D7913-14. Standard Test Method for Bond Strength of Fiber-Reinforced Polymer Matrix Composite Bars to Concrete by Pullout Testing".
[10]  
[Anonymous], ASTM D2584-18. Standard test method for ignition loss of cured reinforced resins