A birdcage transmit, 24-channel conformal receive array coil for sensitive 31P magnetic resonance spectroscopic imaging of the human brain at 7 T

被引:0
作者
Hovagimian, Johnny Der [1 ,2 ]
Yazdanbakhsh, Pedram [1 ,3 ]
Halilibrahimoglu, Hande [1 ,2 ]
Couch, Marcus J. [1 ,3 ,4 ]
Hoge, Richard [1 ,2 ,3 ]
Rudko, David A. [1 ,2 ,3 ,5 ]
机构
[1] Montreal Neurol Hosp & Inst, McConnell Brain Imaging Ctr, Montreal, PQ, Canada
[2] McGill Univ, Dept Biomed Engn, Montreal, PQ, Canada
[3] McGill Univ, Dept Neurol & Neurosurg, Montreal, PQ, Canada
[4] Siemens Healthcare Ltd, Montreal, PQ, Canada
[5] McGill Univ, Montreal Neurol Inst, 3801 Univ St, Montreal, PQ H3A 2B4, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
coil design; magnetic resonance spectroscopy; phased array; phosphorus; spectroscopic imaging; PHOSPHORUS; MRS; EFFICIENT;
D O I
10.1002/nbm.5178
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Phosphorus (P-31) magnetic resonance spectroscopic imaging (MRSI) can serve as a critical tool for more direct quantification of brain energy metabolism, tissue pH, and cell membrane turnover. However, the low concentration of P-31 metabolites in biological tissue may result in low signal-to-noise ratio (SNR) in P-31 MRS images. In this work, we present an innovative design and construction of a P-31 radiofrequency coil for whole-brain MRSI at 7 T. Our coil builds on current literature in ultra-high field P-31 coil design and offers complete coverage of the brain, including the cerebellum and brainstem. The coil consists of an actively detunable volume transmit (Tx) resonator and a custom 24-channel receive (Rx) array. The volume Tx resonator is a 16-rung high-pass birdcage coil. The Rx coil consists of a 24-element phased array composed of catered loop shapes and sizes built onto a custom, close-fitting, head-shaped housing. The Rx array was designed to provide complete coverage of the head, while minimizing mutual coupling. The Rx configuration had a mean S-11 reflection coefficient better than -20 decibels (dB) when the coil was loaded with a human head. The mean mutual coupling (S-21) among Rx elements, when loaded with a human head, was -16 dB. In phantom imaging, the phased array produced a central SNR that was 4.4-fold higher than the corresponding central SNR when operating the P-31 birdcage as a transceiver. The peripheral SNR was 12-fold higher when applying the optimized phased array. In vivo 3D P-31 MRSI experiments produced high-quality spectra in the cerebrum gray and white matter, as well as in the cerebellum. Characteristic phosphorus metabolites related to adenosine triphosphate metabolism and cell membrane turnover were distinguishable across all brain regions. In summary, our results demonstrate the potential of our novel coil for accurate, whole-brain P-31 metabolite quantification.
引用
收藏
页数:15
相关论文
共 28 条
  • [1] Double-tuned 31P/1H human head array with high performance at both frequencies for spectroscopic imaging at 9.4T
    Avdievich, Nikolai, I
    Ruhm, Loreen
    Dorst, Johanna
    Scheffler, Klaus
    Korzowski, Andreas
    Henning, Anke
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (02) : 1076 - 1089
  • [2] Time-domain combination of MR spectroscopy data acquired using phased-array coils
    Brown, MA
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) : 1207 - 1213
  • [3] A nested phosphorus and proton coil array for brain magnetic resonance imaging and spectroscopy
    Brown, Ryan
    Lakshmanan, Karthik
    Madelin, Guillaume
    Parasoglou, Prodromos
    [J]. NEUROIMAGE, 2016, 124 : 602 - 611
  • [4] Saturated double-angle method for rapid B1 plus mapping
    Cunningham, Charles H.
    Pauly, John M.
    Nayak, Krishna S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1326 - 1333
  • [5] Phosphate Brain Energy Metabolism and Cognition in Alzheimer's Disease: A Spectroscopy Study Using Whole-Brain Volume-Coil 31Phosphorus Magnetic Resonance Spectroscopy at 7Tesla
    Das, Namrata
    Ren, Jimin
    Spence, Jeffrey
    Chapman, Sandra Bond
    [J]. FRONTIERS IN NEUROSCIENCE, 2021, 15
  • [6] Signal-to-noise ratio and parallel Imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla
    de Zwart, JA
    Ledden, PJ
    van Gelderen, P
    Bodurka, J
    Chu, RX
    Duyn, JH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (01) : 22 - 26
  • [7] Haase A, 2000, CONCEPT MAGNETIC RES, V12, P361, DOI 10.1002/1099-0534(2000)12:6<361::AID-CMR1>3.0.CO
  • [8] 2-L
  • [9] AN EFFICIENT, HIGHLY HOMOGENEOUS RADIOFREQUENCY COIL FOR WHOLE-BODY NMR IMAGING AT 1.5-T
    HAYES, CE
    EDELSTEIN, WA
    SCHENCK, JF
    MUELLER, OM
    EASH, M
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 63 (03) : 622 - 628
  • [10] Adenosine Triphosphate Metabolism Measured by Phosphorus Magnetic Resonance Spectroscopy: A Potential Biomarker for Multiple Sclerosis Severity
    Kauv, Paul
    Ayache, Samar S.
    Creange, Alain
    Chalah, Moussa A.
    Lefaucheur, Jean-Pascal
    Hodel, Jerome
    Brugieres, Pierre
    [J]. EUROPEAN NEUROLOGY, 2017, 77 (5-6) : 316 - 321