Design Optimization and Characterization of a 3-D-Printed Tactile Sensor for Tissue Palpation

被引:6
作者
Lo Presti, D. [1 ,2 ]
Zoboli, L. [1 ]
Addabbo, A. [1 ,2 ]
Bianchi, D. [1 ]
Dimo, A. [1 ,2 ]
Massaroni, C. [1 ,2 ]
Altomare, V. [3 ]
Grasso, A. [3 ]
Gizzi, A. [1 ]
Schena, E. [1 ]
机构
[1] Univ Campus Bio Med Roma, Dept Engn, Unit Measurements & Biomed Instrumentat, I-00128 Rome, Italy
[2] Fdn Policlin Univ Campus Biomed, I-00128 Rome, Italy
[3] Fdn Policlin Univ Campus Biomed, Breast Surg Unit, I-00128 Rome, Italy
关键词
3-D printing; additive manufacturing; fiber Bragg gratings (FBGs); tactile sensing; tissue palpation; MR ELASTOGRAPHY; FORCE; PROSTATE; CELLS; FBG;
D O I
10.1109/JSEN.2024.3369337
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Manual palpation is a crucial medical procedure that relies on surface examination to detect internal tissue abnormalities, heavily reliant on healthcare professionals' expertise and tactile sensitivity. To tackle these issues, smart palpation systems based on electrical or optical sensors have been developed to perform quantitative tactile measurements, crucial for identifying various solid tumors, including breast and prostate cancer by assessing tissue mechanical properties. In this context, fiber Bragg gratings (FBGs) are emerging as a an ideal candidate for tactile sensing due to their advantages (e.g., high metrological properties, multiplexing capacity, and easy packaging). This study explores the benefits of FBG and 3-D printing to develop a tactile sensor for tissue palpation. First, an optimization of the design of the sensing core of a previously developed probe was conducted through finite element analysis. The novel structure addresses the primary limitation of the previous solution, where nonuniform strain distribution on the encapsulated FBG causes compression on the grating with high risk of bending and breakage. In contrast, the modeled geometry ensures FBG elongation during tissue palpation. A 3-D printing and characterization of the proposed solution was carried out to investigate the response of the enclosed FBG when pushed against different materials showing promising results in discriminating tissues according to their mechanical properties: the more rigid the indented substrate, the higher the sensor output. This property will be fundamental for enhancing early tumor detection through superficial tissue palpation, advancing the efficacy of prevention measures.
引用
收藏
页码:12366 / 12373
页数:8
相关论文
共 34 条
[31]   Tactile Sensing Systems for Tumor Characterization: A Review [J].
Won, Chang-Hee ;
Lee, Jong-Ha ;
Saleheen, Firdous .
IEEE SENSORS JOURNAL, 2021, 21 (11) :12578-12588
[32]  
Wu ZC, 2020, IEEE INT CONF ROBOT, P1625, DOI [10.1109/icra40945.2020.9197128, 10.1109/ICRA40945.2020.9197128]
[33]   Fiber Bragg grating online packaging technology based on 3D printing [J].
Yan, Wen ;
Ma, Shengran ;
Wang, Hongzhi ;
Zhang, Xinpu .
OPTICS AND LASER TECHNOLOGY, 2020, 131
[34]   A Novel Bioinspired Whisker Sensor for Gastrointestinal Endoscopy [J].
Zhang, Zheng ;
Zhang, Chi ;
Zuo, Siyang .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2024, 29 (01) :636-646