A novel low-background nitroreductase fluorescent probe for real-time fluorescence imaging and surgical guidance of thyroid cancer resection

被引:5
|
作者
Zhang, Siqi [1 ]
Ma, Mo [1 ,2 ]
Zhao, Chen [1 ]
Li, Jingkang [1 ]
Xu, Lanlan [1 ]
Zhang, Zihe [3 ]
Diao, Quanping [4 ]
Ma, Pinyi [1 ]
Song, Daqian [1 ,4 ]
机构
[1] Jilin Univ, Coll Chem, Jilin Prov Res Ctr Engn & Technol Spectral Analyt, Qianjin St 2699, Changchun 130012, Peoples R China
[2] Jilin Univ, Sch Pharm, Qianjin St 2699, Changchun 130012, Peoples R China
[3] China Med Univ, Hosp 1, 77 Puhe Rd,Shenyang North New Area, Shenyang 110122, Peoples R China
[4] Anshan Normal Univ, Sch Chem & Life Sci, Liaoning Key Lab Dev & Utilizat Nat Prod Act Mol, Anshan, Peoples R China
基金
中国国家自然科学基金;
关键词
Nitroreductase; Low background fluorescence; Thyroid cancer; Fluorescence probe; Imaging in vivo; LIVING CELLS; HYPOXIA; ZEBRAFISH; DIAGNOSIS; TISSUES; TUMORS;
D O I
10.1016/j.bios.2024.116514
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Thyroid cancer always appears insidiously with few noticeable clinical symptoms. Due to its limitations, conventional ultrasound imaging can lead to missed or misdiagnosed cases. Surgery is still the primary treatment method of thyroid cancer, but removal of surrounding healthy tissues to minimize recurrence leads to overtreatment and added patient suffering. To address this challenge, herein, a nitroreductase (NTR) fluorescent probe, Ox-NTR, has been developed for detecting thyroid cancer and tracking the surgical removal of thyroid tumors by fluorescence imaging. The conjugated structure of oxazine 1 was disrupted, significantly reducing the issue of high background signals, thus effectively achieving low background fluorescence. Under hypoxic conditions, the nitro group of Ox-NTR can be reduced to an amine and subsequently decomposed into oxazine 1, emitting intense red fluorescence. Ox-NTR has a low detection limit of 0.09 mu g/mL for NTR with excellent photostability and selectivity. Cellular studies show that Ox-NTR can effectively detect NTR levels in hypoxic thyroid cancer cells. Moreover, the ability of Ox-NTR of rapid response to thyroid cancer in vivo is confirmed by fluorescence imaging in mice, distinguishing tumors from normal tissues due to its superior low background fluorescence. Utilizing this fluorescence imaging method during surgical resection can guide the removal of tumors, preventing both missed tumor tissues and accidental removal of healthy tissue. In summary, the novel Ox-NTR offers precise detection capabilities that provide significant advantages over traditional imaging methods for thyroid cancer diagnosis and treatment, making it a valuable tool to guide tumor removal in surgical procedures.
引用
收藏
页数:7
相关论文
共 36 条
  • [1] A turn on fluorescent probe for nitroreductase activity and its application in real-time imaging of tumor hypoxia
    Gao, Weijie
    Shi, Anyang
    Hou, Yunzhuo
    Zhang, Peng
    Zhang, Qian
    Ding, Caifeng
    TALANTA, 2025, 290
  • [2] A Novel Fluorescent Probe for Nitroreductase Detection and Imaging of cancer Cells under Hypoxia Conditions
    Sun, Tong
    Wu, Lei
    Cui, Mengyuan
    Zhao, Guisen
    JOURNAL OF FLUORESCENCE, 2024,
  • [3] Real-time Imaging of Tumor Progression in a Fluorescent Orthotopic Mouse Model of Thyroid Cancer
    Cao, Hop S. Tran
    Kaushal, Sharmeela
    Snyder, Cynthia S.
    Ongkeko, Weg M.
    Hoffman, Robert M.
    Bouvet, Michael
    ANTICANCER RESEARCH, 2010, 30 (11) : 4415 - 4422
  • [4] A Pyroglutamate Aminopeptidase 1 Responsive Fluorescence Imaging Probe for Real-Time Rapid Differentiation between Thyroiditis and Thyroid Cancer
    Zhang, Siqi
    Ma, Mo
    Li, Jingkang
    Li, Jiaxin
    Xu, Lanlan
    Gao, Dejiang
    Ma, Pinyi
    Han, Hui
    Song, Daqian
    ANALYTICAL CHEMISTRY, 2024, 96 (15) : 5897 - 5905
  • [5] A novel fluorescent probe with extremely low background fluorescence for sensing hypochlorite in zebrafish
    Han, Zhixiang
    Dong, Lianghuan
    Sun, Fan
    Long, Lingliang
    Jiang, Shu
    Dai, Xiaoting
    Zhang, Min
    ANALYTICAL BIOCHEMISTRY, 2020, 602
  • [6] Real-Time Thermoacoustic Imaging-Guidance for Breast Tumor Resection
    Qin, Huan
    Cui, Yongsheng
    Wu, Zhujun
    Chen, Qun
    Xing, Da
    IEEE PHOTONICS JOURNAL, 2020, 12 (03):
  • [7] highly selective ratiometric fluorescent probe for real-time imaging of β-glucuronidase in living cells and zebrafish
    Huo, Xiaokui
    Tian, Xiangge
    Li, Yannan
    Feng, Lei
    Cui, Yonglei
    Wang, Chao
    Cui, Jingnan
    Sun, Chengpeng
    Liu, Kexin
    Ma, Xiaochi
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 262 : 508 - 515
  • [8] A Novel Fluorescent Probe Strategy Activated by β-Glucuronidase for Assisting Surgical Resection of Liver Cancer
    Wang, Jiemin
    Zhang, Liang
    Su, Yaling
    Qu, Yi
    Cao, Yuping
    Qin, Wenwu
    Liu, Yun
    ANALYTICAL CHEMISTRY, 2022, 94 (19) : 7012 - 7020
  • [9] Ultra-sensitive and fast nitroreductase-responsive fluorescence probe for real-time bioimaging of hypoxia in tumor cells and zebrafish wound inflammation
    An, Zhihao
    Sun, Yanli
    Wang, Danni
    Ge, Ju
    Zhao, Caibing
    Lu, Hongzhao
    Ai, Taotao
    Li, Hua
    Zhang, Shengrui
    Wang, Qin
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 420
  • [10] A novel quinoline-based fluorescent probe for real-time monitoring of Cys in glioma
    Zeng, Shang-Ming-Zhu
    Zhang, Qing
    Li, Qin
    Yuan, Liang-Chao
    Abbas, Muhammad
    He, Zhen-Xiang
    Zhu, Hai-Liang
    Wang, Zhong-Chang
    ANALYST, 2022, 147 (19) : 4257 - 4265