Biomechanical properties of bicortical and monocortical plate fixation for rib fractures in the adolescent human rib fracture model

被引:0
作者
Glowacki, Jakub [1 ]
Bartkowiak, Tomasz [2 ]
Paczos, Piotr [3 ]
Zielinski, Michal [2 ]
Smyczynski, Miko laj [3 ]
Pelic, Marcin [2 ]
机构
[1] Poznan Univ Med Sci, Dept Gen Orthopaed Musculoskeletal Oncol & Trauma, Poznan, Poland
[2] Poznan Univ Tech, Inst Mech Technol, Poznan, Poland
[3] Poznan Univ Tech, Inst Appl Mech, Poznan, Poland
关键词
monocortical fixation; rib fractures; osteosynthesis; CHEST-WALL; SURGICAL STABILIZATION; OPERATIVE STABILIZATION; MANAGEMENT; BONE; TOUGHNESS; MORTALITY; INJURIES; STRENGTH; AGE;
D O I
10.37190/ABB-02349-2023-02
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Purpose: The technical advancement of surgical stabilization of ribs often prevents the surgeons from fixation, despite the procedures documented improved outcomes. The aim of this study was to evaluate a less invasive approach involving a simplified monocortical rib fixation technique. Methods: Eighteen frozen human ribs obtained intraoperatively from young individuals aged 13-18 were employed for this study. First, the ribs were fractured under three-point bending, with their intrathoracic side put under tensile stress. Following this, the ChM 4.0 rib fixation system was utilized. The specimens were categorized into two groups: bicortical fixation (n = 9) and monocortical fixation (n = 9). Subsequently, bicortical and monocortical fixation groups underwent dynamic testing over 400 000 cycles under combined sinusoidal tensile bending and torsional loading (2-5 N at 3 Hz). In the final stage, all samples were subjected to a destructive load to failure. Results: Our analysis revealed that the fixation method did not demonstrate statistically significant differences in terms of preliminary bending stiffness ( p = 0.379). Similarly, undergoing a course of 400 000 cycles involving combined tensile and torsional loading did not constitute a statistically significant factor affecting the monocortical and the bicortical fixation groups ( p = 0.894). In the monocortical fixation group, all specimens failed due to screws pulled out from the bone. In contrast, all specimens in the bicortical fixation group exhibited failure attributed to fractures occurring just behind the plate. Nonetheless, the fixation method was not a significant factor affecting bending strength ( p = 0.863). Conclusions: The monocortial fixation could be a reasonable option among younger populations with comparable stability of fixation.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 24 条
  • [21] Six Sigma Analysis of Mini-Plate Fixation Systems Used in Human Mandible Fractures: A Clinical Case Study of Symphysis Fracture
    Shokry, Abdallah
    Kharmanda, Ghais
    Mulki, Hasan
    Kharma, Mohamed Yaser
    Mahmoud, Saleh
    APPLIED SCIENCES-BASEL, 2023, 13 (22):
  • [22] Osteosynthesis of partial rib osteotomy in a miniature pig model using human standard-sized magnesium plate/screw systems: Effect of cyclic deformation on implant integrity and bone healing
    Schaller, Benoit
    Saulacic, Nikola
    Beck, Stefan
    Imwinkelried, Thomas
    Liu, Edwin Wei Yang
    Nakahara, Ken
    Hofstetter, Willy
    Iizuka, Tateyuki
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2017, 45 (06) : 862 - 871
  • [23] Biomechanical analysis of polyaxial locking vs. non-locking plate fixation of unstable fractures of the distal fibula: A cadaver study with a bone only model
    Hallbauer, J.
    Graefenstein, A.
    Rausch, S.
    Knobe, M.
    Simons, P.
    Mueckley, T.
    Hofmann, G. O.
    Klos, K.
    FOOT AND ANKLE SURGERY, 2018, 24 (04) : 326 - 329
  • [24] A biomechanical comparison of Kirschner-wire fixation on fracture stability in Salter-Harris type I fractures of the proximal humeral physis in a porcine cadaveric model
    Ma, Jiawen
    Wang, Tian
    Lovric, Vedran
    Johnson, Kenneth A.
    Walsh, William R.
    BMC VETERINARY RESEARCH, 2017, 13