A Modified Switching Procedure from Temporary to Tunneled Central Venous Dialysis Catheters

被引:1
作者
Eberhard, Johannes [1 ]
Bedau, Constantin [1 ]
Chapple, Andrew Genius [2 ]
Klein, Julia [1 ]
Reissfelder, Christoph [1 ]
Kaelsch, Anna-Isabelle [3 ]
Gerken, Andreas Lutz Heinrich [1 ]
Zach, Sebastian [1 ]
Schwenke, Kay [1 ]
机构
[1] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Surg, D-69117 Mannheim, Germany
[2] LSU Hlth Sci Ctr, Sch Med, Dept Interdisciplinary Oncol, Biostat Core, New Orleans, LA 70112 USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Dept Med Nephrol Endocrinol Rheumatol 5, D-69117 Mannheim, Germany
关键词
hemodialysis; catheter; tunneled catheter; temporary catheter; guidewire exchange; infection; HEMODIALYSIS CATHETERS; CONVERSION; COMPLICATIONS;
D O I
10.3390/jcm13123367
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Tunneled central venous catheters are commonly used for dialysis in patients without a functional permanent vascular access. In an emergent setting, a non-tunneled, temporary central venous catheter is often placed for immediate dialysis. The most critical step in the catheter insertion is venipuncture, which is often a major cause for longer intervention times and procedure-related adverse events. To avoid this critical step when placing a more permanent tunneled catheter, an exchange over a previously placed temporary one can be considered. In this paper, we present a modified switching approach with a separate access site. Methods: In this retrospective analysis of a prospective database, we examined whether this modified technique is non-inferior to a de novo application. Therefore, we included all 396 patients who received their first tunneled dialysis catheter at our site from March 2018 to March 2023. Out of these, 143 patients received the modified approach and 253 the standard de novo ultrasound-guided puncture and insertion. Then, the outcomes of the two groups, including adverse events and infections, were compared by nonparametric tests and multivariable logistic regression. Results: In both groups, the implantations were 100% successful. Catheter explantation due to infection according to CDC criteria was necessary in 18 cases, with no difference between the groups (5.0% vs. 4.4% p = 0.80). The infection rate per 100 days was 0.113 vs. 0.106 in the control group, with a comparable spectrum of bacteria. A total of 12 catheters (3 vs. 9) had to be removed due to a periinterventional complication. An early-onset infection was the reason in two cases (1.3%) in the study group and five in the control group (1.9%). A total misplacement of the catheter occurred in two cases only in the control group. After adjustment for potential confounders via multivariable logistic regression there was not a significant difference in the complication rate (adjusted odds ratio, aOR = 0.53, 95% CI = 0.14-2.03, p = 0.351) but an estimated decreased risk overall based on the average treatment effect of -1.7% in favor of the study group. Conclusions: The present study shows that a catheter exchange leads to no more infections than a de novo placement; hence, it is a feasible method. Moreover, misplacements and control chest X-rays to exclude pneumothorax after venipuncture were completely avoided by exchanging. This approach yields a much lower infection rate than previous reports: 1.3% compared to 2.7% in all existing aggregated studies. The presented approach seems to be superior to existing switching methods. Overall, an exchange can also help to preserve veins for future access, since the same jugular vein is used.
引用
收藏
页数:9
相关论文
共 20 条
[1]   Mechanical complications after central venous catheterisation in the ultrasound-guided era: a prospective multicentre cohort study [J].
Adrian, Maria ;
Borgquist, Ola ;
Kroger, Tina ;
Linne, Erik ;
Bentzer, Peter ;
Spangfors, Martin ;
Akeson, Jonas ;
Holmstrom, Anders ;
Linner, Rikard ;
Kander, Thomas .
BRITISH JOURNAL OF ANAESTHESIA, 2022, 129 (06) :843-850
[2]   De Novo Central Vein Stenosis in Hemodialysis Patients Following Initial Tunneled Central Vein Catheter Placement [J].
Al-Balas, Alian ;
Almehmi, Ammar ;
Varma, Rakesh ;
Al-Balas, Hassan ;
Allon, Michael .
KIDNEY360, 2022, 3 (01) :99-102
[3]   Tunnelled catheters for the haemodialysis patient [J].
Bagul, A. ;
Brook, N. R. ;
Kaushik, M. ;
Nicholson, M. L. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2007, 33 (01) :105-112
[4]   A single institutional experience of conversion of non-tunneled to tunneled hemodialysis catheters: a comparison to de novo placement [J].
Bajaj, Sunil Kumar ;
Ciacci, Joseph ;
Kirsch, Matthias ;
Ebersole, John D. .
INTERNATIONAL UROLOGY AND NEPHROLOGY, 2013, 45 (06) :1753-1759
[5]   Infection Associated with Tunneled Hemodialysis Catheters [J].
Beathard, Gerald A. ;
Urbanes, Aris .
SEMINARS IN DIALYSIS, 2008, 21 (06) :528-538
[6]   The Survival Benefit of "Fistula First, Catheter Last" in Hemodialysis Is Primarily Due to Patient Factors [J].
Brown, Robert S. ;
Patibandla, Bhanu K. ;
Goldfarb-Rumyantzev, Alexander S. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2017, 28 (02) :645-652
[7]   Tunneled central venous catheters for hemodialysis-unfairly condemned? Catheter-related complications in a university hospital setting [J].
Buckenmayer, Anna ;
Moeller, Bianca ;
Ostermaier, Claudia ;
Hoyer, Joachim ;
Haas, Christian S. .
JOURNAL OF VASCULAR ACCESS, 2024, 25 (04) :1212-1218
[8]  
Chouhani B A, 2022, J Med Vasc, V47, P87, DOI 10.1016/j.jdmv.2022.04.007
[9]   Central venous catheter replacement strategies: A systematic review of the literature [J].
Cook, D ;
Randolph, A ;
Kernerman, P ;
Cupido, C ;
King, D ;
Soukup, C ;
BrunBuisson, C .
CRITICAL CARE MEDICINE, 1997, 25 (08) :1417-1424
[10]   Evaluation of catheter infection rates in converted dialysis catheters versus de novo placement in the setting of chlorhexidine use [J].
Criddle, Jared M. ;
Hieb, Robert A. ;
White, Sarah B. ;
Patel, Parag J. ;
Hohenwalter, Eric J. ;
Tutton, Sean M. ;
Rilling, William S. .
JOURNAL OF VASCULAR ACCESS, 2016, 17 (02) :162-166