Carotid and aortic plaque imaging using 3D gradient-echo imaging and the three-point Dixon method with improved motion-sensitized driven-equilibrium (iMSDE)

被引:0
作者
Koori, Norikazu [1 ,2 ]
Kamekawa, Hiroki [3 ]
Naito, Takehiro [4 ]
Takatsu, Yasuo [2 ,5 ]
Fuse, Hiraku [1 ]
Miyakawa, Shin [1 ]
Yasue, Kenji [1 ]
Takahashi, Masato [1 ]
Kurata, Kazuma [3 ]
机构
[1] Ibaraki Prefectural Univ Hlth Sci, Dept Radiol Sci, 4669-2 Ami, Ibaraki 30003, Japan
[2] Kanazawa Univ, Div Hlth Sci, Grad Sch Med Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan
[3] Komaki City Hosp, Dept Radiol, 1-20 Jyoubushi, Komaki, Aichi 4858520, Japan
[4] Komaki City Hosp, Dept Neurosurg, 1-20 Jyoubushi, Komaki, Aichi 4858520, Japan
[5] Fujita Hlth Univ, Sch Med Sci, Mol Imaging, 1-98 Dengakugakubo,Kutsukake cho, Toyoake, Aichi 4701192, Japan
关键词
iMSDE; Dixon; Plaque imaging; Black blood; Aortic plaque; VISTA; INTRAPLAQUE HEMORRHAGE; ARTERY; MRI; COMPONENTS; ARTIFACTS; CONTRAST; PROTON; IMAGES; RISK; ARCH;
D O I
10.1016/j.mri.2024.03.036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: We devised a method that combines the 3D-Dixon-gradientecho (GRE) method with an improved motion-sensitized driven-equilibrium (iMSDE) to suppress blood flow signals. Purpose: The purpose of this study was to evaluate the effectiveness of the new method we developed plaque imaging method (3D-Dixon-GRE with the iMSDE method). Study type: Retrospective cohort. Population: Thirty-nine patients who underwent cervical plaque imaging. FIELD STRENGTH/SEQUENCE:3.0 T/3D-GRE. Assessment: Signal intensities of the common carotid artery, aorta, plaque, muscle, and subcutaneous fat were measured through the VISTA and the 3D-Dixon-GRE with iMSDE methods, and each contrast was calculated. Statistical test: Used the Mann Whitney U test. P-values below 0.05 were considered statistically significant. Results: Plaque and muscle contrast estimated through the VISTA method and 3D-Dixon-GRE with iMSDE method was 1.60 +/- 0.96 and 2.04 +/- 1.06, respectively, (P < 0.05). The contrast between the flow (common carotid artery and Aorta) and muscle according to the VISTA method and 3D-Dixon-GRE with iMSDE method was 0.24 +/- 0.11 and 0.40 +/- 0.12, respectively (P < 0.001). Finally, the mean contrast for subcutaneous fat and muscle at six locations was 3.05 +/- 1.25 and 0.81 +/- 0.23 for the VISTA method and 3D-Dixon-GRE with the iMSDE method, respectively (P < 0.001). Data conclusion: Compared to the conventional method (VISTA), the 3D-Dixon-GRE with iMSDE method is preferable in relation to the fat suppression effect, but it is disadvantageous regarding blood flow signal suppression. Therefore, the 3D-Dixon-GRE with the iMSDE method could be considered useful for plaque imaging.
引用
收藏
页码:202 / 209
页数:8
相关论文
共 44 条
  • [1] Abrmoff MD., 2004, Biophoton Int, V11, P36, DOI DOI 10.1201/9781420005615.AX4
  • [2] Carotid intraplaque hemorrhage predicts recurrent symptoms in patients with high-grade carotid stenosis
    Altaf, Nishath
    MacSweeney, Shane T.
    Gladman, John
    Auer, Dorothee P.
    [J]. STROKE, 2007, 38 (05) : 1633 - 1635
  • [3] Amarenco P, 1996, NEW ENGL J MED, V334, P1216
  • [5] In vivo 3D high-spatial-resolution MR imaging of intraplaque hemorrhage
    Bitar, Richard
    Moody, Alan R.
    Leung, General
    Symons, Sean
    Crisp, Susan
    Butany, Jagdish
    Rowsell, Corwyn
    Kiss, Alexander
    Nelson, Andrew
    Maggisano, Robert
    [J]. RADIOLOGY, 2008, 249 (01) : 259 - 267
  • [6] Swallowing, arterial pulsation, and breathing induce motion artifacts in carotid artery MRI
    Boussel, L
    Herigault, G
    de la Vega, A
    Nonent, M
    Douek, PC
    Serfaty, JM
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (03) : 413 - 415
  • [7] The Relationship Between Aortic Arch Calcification and Recurrent Stroke in Patients With Embolic Stroke of Undetermined Source-A Case-Control Study
    Cai, Xiaofeng
    Geng, Yu
    Zhang, Sheng
    [J]. FRONTIERS IN NEUROLOGY, 2022, 13
  • [8] Hemorrhage in the atherosclerotic carotid plaque: A high-resolution MRI study
    Chu, BC
    Kampschulte, A
    Ferguson, MS
    Kerwin, WS
    Yarnykh, VL
    O'Brien, KD
    Polissar, NL
    Hatsukami, TS
    Yuan, C
    [J]. STROKE, 2004, 35 (05) : 1079 - 1084
  • [9] SIMPLE PROTON SPECTROSCOPIC IMAGING
    DIXON, WT
    [J]. RADIOLOGY, 1984, 153 (01) : 189 - 194
  • [10] Carotid Arterial Wall MRI at 3T Using 3D Variable-Flip-Angle Turbo Spin-Echo (TSE) with Flow-Sensitive Dephasing (FSD)
    Fan, Zhaoyang
    Zhang, Zhuoli
    Chung, Yiu-Cho
    Weale, Peter
    Zuehlsdorff, Sven
    Carr, James
    Li, Debiao
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 645 - 654