Micro-WEDM of Ti-29Nb-13Ta-4.6Zr Alloy for Antibacterial Properties: Experimental Investigation and Optimization

被引:0
作者
Ali, Shahid [1 ]
Omarov, Salikh [1 ]
Utebayeva, Altynay [2 ]
Pham, Tri Thanh [2 ]
Talamona, Didier [1 ]
Perveen, Asma [1 ]
机构
[1] Nazarbayev Univ, Sch Engn & Digital Sci, Dept Mech & Aerosp Engn, Astana 010000, Kazakhstan
[2] Nazarbayev Univ, Sch Sci & Humanities, Dept Biol, Astana 010000, Kazakhstan
关键词
WEDM; beta titanium alloy; TNTZ; biocompatibility; surface treatment; biofilm formation; Taguchi optimization; antibacterial; NB-TA-ZR; MECHANICAL-PROPERTIES; TITANIUM-ALLOY; WEAR CHARACTERISTICS; CORROSION BEHAVIOR; TI-6AL-4V ALLOY; PERFORMANCE; TI; ROUGHNESS;
D O I
10.3390/met14060714
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recent developments of orthopedic implant applications have discovered a variety of new metallic biomaterials known as beta-type titanium alloys. The mu-WEDM (micro-wire electro discharge machining) surface treatment technique, capable of improving the surface properties of orthopedic implants, was studied in a machining Ti-29Nb-13Ta-4.6Zr alloy. This study aimed to evaluate material removal rate (MRR), kerf width, average surface roughness, microhardness and antibacterial response at different machining parameters which are capacitance (1 nF, 10 nF and 100 nF) and gap voltage (80 V, 95 V and 110 V). The Taguchi method was used to optimize the mentioned output parameters, while ANOVA (analysis of variance) described the significance and contribution of capacitance and gap voltage. Grey relation analysis (GRA) was conducted to perform multiple output optimization. For antibacterial response, cultivations of B. subtilis, E. coli, P. aeruginosa and S. aureus bacteria on treated surfaces for 72 h were performed. As the results, optimal values of MRR, kerf width, crater area, average surface roughness and microhardness were equal to 0.0637 mm3/min, 93.0 mu m, 21.8 mu m2, 0.348 mu m and 442 HV, respectively. Meanwhile, mu-WEDM treatment improved antibacterial properties while the highest antibacterial response was achieved at the lowest average surface roughness resulting in least biofilm formation on treated surfaces.
引用
收藏
页数:20
相关论文
共 51 条
  • [21] ROUGHNESS AND WEAR CHARACTERISTICS OF SPARK-ERODED SURFACES
    JESWANI, ML
    [J]. WEAR, 1978, 51 (02) : 227 - 236
  • [22] Review on titanium and titanium based alloys as biomaterials for orthopaedic applications
    Kaur, Manmeet
    Singh, K.
    [J]. MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 102 : 844 - 862
  • [23] Hindrance of osteoblast cell adhesion on titanium by surface nanostructuring
    Knapic, Dominik
    Minenkov, Alexey
    Luczak, Wiktor
    Zrinski, Ivana
    Kleber, Christoph
    Hild, Sabine
    Weth, Agnes
    Hassel, Achim Walter
    Mardare, Andrei Ionut
    [J]. SURFACES AND INTERFACES, 2024, 46
  • [24] Castability and mechanical properties of Ti-15Mo-5Zr-3Al alloy in dental casting
    Koizumi, Hiroyasu
    Ishii, Takaya
    Okazaki, Tomoyo
    Kaketani, Masahiro
    Matsumura, Hideo
    Yoneyama, Takayuki
    [J]. JOURNAL OF ORAL SCIENCE, 2018, 60 (02) : 285 - 292
  • [25] Multiresponse optimization of micro-wire electrical discharge machining process
    Kuriachen, B.
    Somashekhar, K. P.
    Mathew, Jose
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2015, 76 (1-4) : 91 - 104
  • [26] YOUNGS MODULUS AND DAMPING OF TI-6AL-4V ALLOY AS A FUNCTION OF HEAT-TREATMENT AND OXYGEN CONCENTRATION
    LEE, YT
    WELSCH, G
    [J]. MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1990, 128 (01): : 77 - 89
  • [27] Wear characteristics of Ti-Nb-Ta-Zr and Ti-6Al-4V alloys for biomedical applications
    Li, SJ
    Yang, R
    Li, S
    Hao, YL
    Cui, YY
    Niinomi, M
    Guo, ZX
    [J]. WEAR, 2004, 257 (9-10) : 869 - 876
  • [28] Role of implants surface modification in osseointegration: A systematic review
    Liu, Yu
    Rath, Bjoern
    Tingart, Markus
    Eschweiler, Joerg
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2020, 108 (03) : 470 - 484
  • [29] Wire Electric Discharge Machining at Different Slant Angles during Slant Type Taper Profiling of Microfer 4722 Superalloy
    Manoj, I., V
    Narendranath, S.
    [J]. JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2022, 31 (01) : 697 - 708
  • [30] Surface Roughness of Dental Implant and Osseointegration
    Matos, Geraldo Roberto Martins
    [J]. JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2021, 20 (01) : 1 - 4