The Effect of Salivary pH on the Flexural Strength and Surface Properties of CAD/CAM Denture Base Materials

被引:16
作者
Alzaid, Maryam [1 ]
AlToraibily, Fatemah [1 ]
Al-Qarni, Faisal D. [2 ]
Al-Thobity, Ahmad M. [2 ]
Akhtar, Sultan [3 ]
Ali, Saqib [4 ]
Al-Harbi, Fahad A. [2 ]
Gad, Mohammed M. [2 ]
机构
[1] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dammam, Saudi Arabia
[2] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Substitut Dent Sci, Dammam 31441, Saudi Arabia
[3] Imam Abdulrahman Bin Faisal Univ, Inst Res & Med Consultat IRMC, Dept Biophys, Dammam, Saudi Arabia
[4] Imam Abdulrahman Bin Faisal Univ, Coll Dent, Dept Biomed Dent Sci, Dammam, Saudi Arabia
关键词
CAD-CAM; 3D printing; polymethyl methacrylate denture base; saliva; mechanical test; WATER SORPTION; IN-VITRO; RESIN; STORAGE;
D O I
10.1055/s-0042-1749160
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aimed to evaluate the influence of different salivary pH on flexural strength, hardness, and surface roughness of computer-aided design and computer-aided manufacturing (CAD/CAM) milled and three-dimensional (3D)-printed denture base resins. Methods One heat-polymerized, two CAD/CAM milled (IvoCad, AvaDent), and two 3D-printed (FormLabs, NextDent) denture base resins were fabricated and divided into five groups (n = 10) according to the solutions: three groups were immersed in different salivary pH (5.7, 7.0, or 8.3), one group was immersed in distilled water (DW) as a positive control, and one group had no immersion (negative control). All immersions were performed at 37 degrees C for 90 days. Flexural strength, hardness, and surface roughness were measured before and after immersion. Data was analyzed with analysis of variance and post hoc Tukey's test (alpha = 0.05). Results After immersion, all specimens had lower flexural strength values when compared with those with no immersion. Comparing the immersion groups, the highest flexural strength value (93.96 +/- 3.18 MPa) was recorded with IvoCad after immersion in DW while the lowest value (60.43 +/- 2.66 MPa) was recorded with NextDent after being immersed in 7.0 pH saliva. All specimens had significant decrease in hardness except IvoCad and AvaDent specimens where both presented the highest surface hardness (53.76 +/- 1.60 Vickers hardness number [VHN]) after immersion in DW while NextDent showed the lowest hardness value (24.91 +/- 2.13 VHN) after being immersed in 8.3 pH saliva. There was statistically significant difference between the baseline and different artificial salivary pH solutions in terms of surfaces roughness, with the highest surface roughness were found in 3D-printed resin materials. Conclusion After exposure to artificial saliva with different salivary pH, the milled CAD/CAM denture base resins showed higher flexural strength, hardness, and lesser surface roughness than conventional and 3D-printed denture base resins.
引用
收藏
页码:234 / 241
页数:8
相关论文
共 42 条
[1]  
Abuzar Menaka A, 2010, J Oral Sci, V52, P577, DOI 10.2334/josnusd.52.577
[2]   A Comparison of the Surface Properties of CAD/CAM and Conventional Polymethylmethacrylate (PMMA) [J].
Al-Dwairi, Ziad N. ;
Tahboub, Kawkab Y. ;
Baba, Nadim Z. ;
Goodacre, Charles J. ;
Ozcan, Mutlu .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (04) :452-457
[3]  
Al-Fouzan AF, 2017, J ADV PROSTHODONT, V9, P402
[4]   Monomer Leakage Behavior of Conventional and CAD/CAM Denture Acrylic Materials Under Different pH Values [J].
Al-Otaibi, Hanan N. ;
Alshaalan, Nouf S. ;
Alqarni, Roba ;
AlMutairi, Reem M. ;
Altaweel, Sara M. ;
Alshehri, Huda A. ;
Alfouzan, Afnan F. .
BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2021, 14 (01) :110-117
[5]  
Alfadda S A., 2020, Biotech Res Comm, V13, P46
[6]   Effects of SiO2 Incorporation on the Flexural Properties of a Denture Base Resin: An In Vitro Study [J].
Alzayyat, Sara T. ;
Almutiri, Ghadah A. ;
Aljandan, Jawhara K. ;
Algarzai, Raneem M. ;
Khan, Soban Q. ;
Akhtar, Sultan ;
Ateeq, Ijlal Shahrukh ;
Gad, Mohammed M. .
EUROPEAN JOURNAL OF DENTISTRY, 2022, 16 (01) :188-194
[7]  
[Anonymous], 2013, INT ORG STANDARDIZAT
[8]  
Anusavice K J., 2003, Phillips' Science of Dental Materials, V722, P754
[9]   The effects of cross-linking agents on the water sorption and solubility characteristics of denture base resin [J].
Arima, T ;
Murata, H ;
Hamada, T .
JOURNAL OF ORAL REHABILITATION, 1996, 23 (07) :476-480
[10]   A DENTURE BASE RESIN WITH LOW WATER-ABSORPTION [J].
BARSBY, MJ .