Cochlear Implantation: Predicting Round Window Niche Visibility Using One Measurement in High-Resolution Temporal Bone Computed Tomography

被引:0
作者
Telmesani, Laila [1 ,2 ]
Al-Ramah, Mona [1 ]
Abdelsamad, Yassin [3 ]
Telmesani, Lena [2 ,4 ]
机构
[1] King Fahad Univ Hosp, Cochlear Implant Unit, Al Khobar, Saudi Arabia
[2] Imam Abdulrahman bin Faisal Univ, Dept ENT, Dammam, Saudi Arabia
[3] MED EL GmbH, Dept Res, Riyadh, Saudi Arabia
[4] King Fahad Univ Hosp, Dept ENT, Al Khobar, Saudi Arabia
关键词
Cochlear implantation; round window niche; hearing loss; anatomy; computed tomography; inner ear malformation; ELECTRODE INSERTION; FACIAL RECESS; ORIENTATION; PERFORMANCE; MEMBRANE;
D O I
10.5152/iao.2024.231199
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
BACKGROUND: To evaluate the accuracy of a single measurement in temporal bone computed tomography in predicting the round window niche (RWN) visibility during cochlear implantation. METHODS: A prospective study was conducted on 148 patients (165 ears) who had a cochlear implant (CI) from January 2010 to December 2018 at a tertiary CI center. The measurement was done for the angle of the basal turn of the cochlea (ABTC), which we defined as the angle formed by the cochlear basal turn and the cranium mid-sagittal plane, by 2 readers blindly from the axial images of computed tomography. The RWN visibility was classified according to the observation during surgery (through posterior tympanotomy) into full visibility, partial visibility, and invisibility. The measured angle was then correlated to the intra-operative visibility of the RWN. RESULTS: The average ABTC was 57.48 degrees +/- 4.05 degrees (range: 45.0-68.0), and the RWN was found to be fully visible in 85%, partially visible in 11%, and invisible in 4% of the studied ears. The receiver operating characteristic analysis revealed a significant discriminating ability in predicting RWN visibility ( P <.001) at a threshold ABTC angle of 58.5 degrees. The mean ABTC was 56.71 degrees +/- 3.74 degrees, 61.00 degrees, and 63.86 degrees +/- 2.67 degrees for fully visible, partially visible, and invisible RWN, respectively. A statistical significant difference was found ( P = .0002) when comparing the ABTC in patients with partially visible/invisible RWN (61.80 degrees +/- 2.87 degrees) with the fully visible RWN (56.71 degrees +/- 3.74 degrees). CONCLUSION: Round window niche visibility could be predicted by measuring the ABTC in relation to the cranium's mid-sagittal plane in CT preoperatively. An ABTC bigger than 58.5 degrees could be an indication of poorly visible RWN.
引用
收藏
页码:94 / 100
页数:104
相关论文
共 21 条
[1]   Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: A histologically controlled insertion study [J].
Adunka, O ;
Unkelbach, MH ;
Mack, M ;
Hambek, M ;
Gstoettner, W ;
Kiefer, J .
ACTA OTO-LARYNGOLOGICA, 2004, 124 (07) :807-812
[2]   Cochlear orientation and dimensions of the facial recess in cochlear implantation [J].
Bettman, RHR ;
Appelman, AMMF ;
van Olphen, AF ;
Zonneveld, FW ;
Huizing, EH .
ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2003, 65 (06) :353-358
[3]  
Briggs R J, 2001, Cochlear Implants Int, V2, P135, DOI 10.1179/cim.2001.2.2.135
[4]   Cochleostomy site: Implications for electrode placement and hearing preservation [J].
Briggs, RJS ;
Tykocinski, M ;
Stidham, K ;
Roberson, JB .
ACTA OTO-LARYNGOLOGICA, 2005, 125 (08) :870-876
[5]   Anatomic variations of the round window niche: radiological study and related endoscopic anatomy [J].
Canzi, Pietro ;
Avato, Irene ;
Manfrin, Marco ;
Simoncelli, Anna Maria ;
Magnetto, Marianna ;
Rebecchi, Elisabetta ;
Tinelli, Carmine ;
Neri, Marinella ;
Beltrame, Millo Achille ;
Benazzo, Marco .
SURGICAL AND RADIOLOGIC ANATOMY, 2019, 41 (07) :853-857
[6]   Predictors of round window membrane visibility in pediatric cochlear implant surgery using temporal bone HRCT: A retrospective study [J].
Chen, Jianqing ;
Wu, Yingwei ;
Shi, Jun ;
Jia, Huan ;
Wang, Zhaoyan ;
Zhang, Zhihua ;
Wu, Hao .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 121 :150-153
[7]  
Cohen David, 2005, Int Tinnitus J, V11, P158
[8]   Cochlear implantation outcomes with round window electrode insertion versus cochleostomy insertion [J].
Elafandi, Haytham ;
Khalifa, Mohamed Adel ;
Elguindy, Ahmed S. .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2020, 138
[9]   Role of Multislice CT Imaging in Predicting the Visibility of the Round Window in Pediatric Cochlear Implantation [J].
Fouad, Yasser A. ;
Elaassar, Ahmad Shaker ;
El-Anwar, Mohammad Waheed ;
Sabir, Ebrahim ;
Abdelhamid, Ahmad ;
Ghonimy, Mai .
OTOLOGY & NEUROTOLOGY, 2017, 38 (08) :1097-1103
[10]   Comparison of Cochlear Implant Performance after Round Window Electrode Insertion Compared with Traditional Cochleostomy [J].
Kang, Bryan J. ;
Kim, Ana H. .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2013, 148 (05) :822-826