Importance of building inspection on the seismic response of a severely damaged RC structure during the February 6, 2023 Kahramanmaras, earthquake sequence

被引:17
作者
Kazaz, Ilker [1 ]
Avsar, Ozguer [2 ]
Dilsiz, Abdullah [3 ]
机构
[1] Erzurum Tech Univ, Dept Civil Engn, TR-25100 Erzurum, Turkiye
[2] Eskisehir Tech Univ, Dept Civil Engn, TR-26555 Eskisehir, Turkiye
[3] Ankara Yildirim Beyazit Univ, Dept Civil Engn, TR-06010 Ankara, Turkiye
关键词
Building Inspection; Structural deficiency; Building damage; Field investigation; Kahramanmaras; earthquake; Soft; -story; REINFORCED-CONCRETE BUILDINGS; PERFORMANCE; DESIGN; WALLS;
D O I
10.1016/j.engfailanal.2024.108410
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Large magnitude February 6, 2023 earthquakes in T & uuml;rkiye created a devastating effect on the building stock on a vast region. For earthquakes of this magnitude, severe damage and collapses are indispensable to the old building stock with deficiencies certified in previous earthquakes. But unexpectedly, the newly constructed buildings that were designed by recent version of Turkish Building Seismic Code (TBEC 2018) also experienced severe damage. After conducting site investigations on one of the recently constructed and severely damaged RC building, a detailed numerical study was performed to identify the reasons for the observed seismic damage. This study pinpoints the main cause of such damage due to lack of thorough building inspections during construction to ensure the implementation of the seismic reinforcement detailing specified in blueprints for providing required ductility, as revealed by field investigations. Additionally, it identifies potential issues stemming from a lack of full comprehension of the seismic design philosophy within the code. The existing design pushes the limits on the axial load level on slender column elements and fall short in capturing the soft story irregularity. Although there is a soft base story in the investigated building, using structural walls only in one direction with moderately confined boundary zones increased its vulnerability. This example shows that in T & uuml;rkiye, where seismic activity is very high and quite lethal, seismic design codes should set stricter limits and measures, and building inspection system must be strictly enforced.
引用
收藏
页数:24
相关论文
共 48 条
[1]  
ACI, ACI 318, ACI 318-19, DOI [10.14359/517169372019, DOI 10.14359/517169372019]
[2]  
AFAD, 2023, Pazarcik-Elbistan (Kahramanmaras) Mw: 7.7-Mw: 7.6 Depremleri Raporu
[3]   Investigating the structural damage in Hatay province after Kahramanmaras,-Türkiye earthquake sequences [J].
Altunsu, Elif ;
Gunes, Onur ;
Ozturk, Sezer ;
Sorosh, Shokrullah ;
Sari, Ali ;
Beeson, Saadet Toker .
ENGINEERING FAILURE ANALYSIS, 2024, 157
[4]  
[Anonymous], 2004, EUROCODE 8 DESIGN ST
[5]  
[Anonymous], 2017, Minimum Design Loads and Associated Criteria for Buildings and Other Structures
[6]  
[Anonymous], 2000, TS500, Requirements for design and construction of reinforced concrete structures
[7]  
[Anonymous], 2004, FEMA 450
[8]  
[Anonymous], 1998, TURKISH EARTHQUAKE C
[9]   What is to be learned from damage and failure of reinforced concrete structures during recent earthquakes in Turkey? [J].
Arslan, M. H. ;
Korkmaz, H. H. .
ENGINEERING FAILURE ANALYSIS, 2007, 14 (01) :1-22
[10]   Performance of RC buildings after Kahramanmaraş Earthquakes: lessons toward performance based design [J].
Binici, Baris ;
Yakut, Ahmet ;
Kadas, Koray ;
Demirel, Ozan ;
Akpinar, Ugur ;
Canbolat, Afsin ;
Yurtseven, Firat ;
Oztaskin, Orkun ;
Aktas, Selin ;
Canbay, Erdem .
EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2023, 22 (04) :883-894