Construction of a Near-Infrared Fluorescent Probe for Dynamic Monitoring and Early Diagnosis of Heart Failure

被引:3
|
作者
Su, Lina [1 ,2 ]
Wang, Junda [3 ]
Liu, Bowei [1 ]
Liu, Hui [3 ]
Chen, Qixin [2 ]
Liu, Jiang [1 ]
Li, Shuolei [4 ]
Yuan, Lan [5 ]
An, Lihua [5 ]
Lin, Hang [2 ]
Feng, Lina [1 ]
Zheng, Jingang [1 ]
Ren, Jingyi [1 ]
Liang, Lei [3 ]
Li, Sufang [2 ]
机构
[1] China Japan Friendship Hosp, Heart Failure Ctr, Dept Cardiol, Beijing 100029, Peoples R China
[2] Peking Univ, Ctr Cardiovasc Translat Res, Beijing Key Lab Early Predict & Intervent Acute M, Peoples Hosp,Dept Cardiol, Beijing 100044, Peoples R China
[3] Peking Univ, Sch Pharmaceut Sci, Dept Med Chem, Beijing 100191, Peoples R China
[4] Peking Univ Peoples Hosp, Lab Anim Unit, Beijing 100044, Peoples R China
[5] Peking Univ, Med & Hlth Analyt Ctr, Beijing 100191, Peoples R China
来源
ACS SENSORS | 2024年 / 9卷 / 06期
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
NIR fluorescence probe; early diagnosis; heartfailure; cells viscosity; cardiac hypertrophy; pyridazinone; RATIONAL DESIGN; FAR-RED; HYDROGEN-PEROXIDE; VISCOSITY; DYES; INFLAMMATION; DERIVATIVES; MODELS; CELLS; IONS;
D O I
10.1021/acssensors.4c00258
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Cardiac hypertrophy characterized by abnormal cardiomyocyte viscosity is a typical sign of heart failure (HF) with vital importance for early diagnosis. However, current biochemical and imaging diagnostic methods are unable to detect this subclinical manifestation. In this work, we developed a series of NIR-I fluorescence probes for detecting myocardial viscosity based on the pyridazinone scaffold. The probes showed weak fluorescence due to free intramolecular rotation under low-viscosity conditions, while they displayed strong fluorescence with limited intramolecular rotation in response to a high-viscosity environment. Among them, CarVis2 exhibited higher stability and photobleaching resistance than commercial dyes. Its specific response to viscosity was not influenced by the pH and biological species. Furthermore, CarVis2 showed rapid and accurate responses to the viscosity of isoproterenol (ISO)-treated H9C2 cardiomyocytes with good biocompatibility. More importantly, CarVis2 demonstrated excellent sensitivity in monitoring myocardial viscosity variation in HF mice in vivo, potentially enabling earlier noninvasive identification of myocardial abnormalities compared to traditional clinical imaging and biomarkers. These findings revealed that CarVis2 can serve as a powerful tool to monitor myocardial viscosity, providing the potential to advance insights into a pathophysiological mechanism and offering a new reference strategy for early visual diagnosis of HF.
引用
收藏
页码:3075 / 3084
页数:10
相关论文
共 50 条
  • [31] A Hydrogen Peroxide Responsive Biotin-Guided Near-Infrared Hemicyanine-Based Fluorescent Probe for Early Cancer Diagnosis
    Zhong, Lingyu
    Wang, Yingfei
    Hao, Qing
    Liu, Hong
    CHEMOSENSORS, 2025, 13 (03)
  • [32] Application of a near-infrared viscosity-responsive fluorescent probe for lysosomal targeting in fatty liver mice
    Hao, Junlei
    Li, Xiao
    Shi, Suntao
    Zhang, Haijuan
    Zhu, Hailiang
    Wu, Jiang
    Gao, Mingyong
    Zhang, Baoxin
    BIOORGANIC CHEMISTRY, 2025, 155
  • [33] A photostable Si-rhodamine-based near-infrared fluorescent probe for monitoring lysosomal pH during heat stroke
    Mao, Guo-Jiang
    Liang, Zhen-Zhen
    Gao, Guang-Qi
    Wang, Ying-Ying
    Guo, Xin-Yu
    Su, Li
    Zhang, Hua
    Ma, Qiu-Juan
    Zhang, Guisheng
    ANALYTICA CHIMICA ACTA, 2019, 1092 : 117 - 125
  • [34] Construction of a Near-Infrared Fluorescent Turn-On Probe for Selenol and Its Bioimaging Application in Living Animals
    Chen, Hua
    Dong, Baoli
    Tang, Yonghe
    Lin, Weiying
    CHEMISTRY-A EUROPEAN JOURNAL, 2015, 21 (33) : 11696 - 11700
  • [35] Application of a Colorimetric and Near-Infrared Fluorescent Probe in Peroxynitrite Detection and Imaging in Living Cells
    Gu, Biao
    Liu, Cunfei
    Wu, Yang
    Zhang, Chunxiang
    Shen, Youming
    Liu, Mengqin
    ACS OMEGA, 2020, 5 (42): : 27530 - 27535
  • [36] Rational design of a fast and selective near-infrared fluorescent probe for targeted monitoring of endogenous nitric oxide
    Tang, Junma
    Guo, Zhiqian
    Zhang, Yutao
    Bai, Bing
    Zhu, Wei-Hong
    CHEMICAL COMMUNICATIONS, 2017, 53 (76) : 10520 - 10523
  • [37] Rational design of a near-infrared fluorescent probe for monitoring butyrylcholinesterase activity and its application in development of inhibitors
    Li, Hao
    Li, Xiao-Dong
    Yan, Chao-Hua
    Ni, Zhen-Hua
    Lu, Mu-Han
    Zou, Li-Wei
    Yang, Ling
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [38] Silicon Rhodamine-Based Near-Infrared Fluorescent Probe for γ-Glutamyltransferase
    Iwatate, Ryu J.
    Kamiya, Mako
    Umezawa, Keitaro
    Kashima, Hiroki
    Nakadate, Mamiko
    Kojima, Ryosuke
    Urano, Yasuteru
    BIOCONJUGATE CHEMISTRY, 2018, 29 (02) : 241 - 244
  • [39] Development of a near-infrared fluorescent probe for the selective detection of severe hypoxia
    Kasai, Takafumi
    Fujita, Kyohhei
    Komatsu, Toru
    Ueno, Tasuku
    Kojima, Ryosuke
    Hanaoka, Kenjiro
    Urano, Yasuteru
    RSC CHEMICAL BIOLOGY, 2025, 6 (03): : 449 - 456
  • [40] Rational Design of a Near-Infrared Fluorescent Probe Based on a Pyridazinone Scaffold
    Zhou, Tongliang
    Yang, Lingfei
    Liang, Lei
    Liu, Hui
    Zhu, Yuanjun
    Shui, Mengyang
    Yuan, Lan
    Xu, Fengrong
    Niu, Yan
    Wang, Chao
    Xu, Ping
    EUROPEAN JOURNAL OF ORGANIC CHEMISTRY, 2017, 2017 (22) : 3274 - 3281