A novel cable configuration method for fully-actuated parallel cable-driven systems: Application in a shoulder rehabilitation exoskeleton

被引:1
作者
Zhang, Fuhai [1 ]
Fu, Yanbo [1 ]
Yang, Lei [1 ]
Fu, Yili [1 ]
机构
[1] Harbin Inst Technol, State Key Lab Robot & Syst, Harbin 150001, Peoples R China
基金
黑龙江省自然科学基金; 中国国家自然科学基金;
关键词
Parallel cable-driven system; Cable configuration; Dynamics; Rehabilitation robotics; Shoulder exoskeleton; Cable length fluctuation; DESIGN; ROBOTS;
D O I
10.1016/j.mechmachtheory.2024.105693
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Cable-driven exoskeletons play a significant role in poststroke rehabilitation. Since cables can only pull but not push, conventional parallel cable-driven exoskeletons are usually over-actuated, leading to uncertain dynamics. This paper proposes a cable configuration method utilizing the antagonistic cable pair to achieve full-actuation. The antagonistic cable pair is formed by assigning a passive impedance cable corresponding to an active driving cable. This method is illustrated as feasible through force closure analysis based on screw theory, and is implemented in a shoulder rehabilitation exoskeleton. Subsequently, the dynamics model of the exoskeleton is formulated, and the isomorphic mapping between cable tension space and joint space is established. Additionally, the elastic fluctuation absorption mechanism is presented to absorb the length fluctuation produced by the antagonistic cable pair, through the deformation of elastic elements. The continuity of cable tension is evidenced through its finite and smooth partial derivatives. Finally, the experimental results of prototype validate that the fully-actuated parallel cable-driven exoskeleton can be achieved with the proposed method.
引用
收藏
页数:19
相关论文
共 28 条
  • [1] Training modalities in robot-mediated upper limb rehabilitation in stroke: a framework for classification based on a systematic review
    Basteris, Angelo
    Nijenhuis, Sharon M.
    Stienen, Arno H. A.
    Buurke, Jaap H.
    Prange, Gerdienke B.
    Amirabdollahian, Farshid
    [J]. JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [2] Bayona Nestor A, 2005, Top Stroke Rehabil, V12, P58
  • [3] Design of a 7-DOF Cable-Driven Arm Exoskeleton (CAREX-7) and a Controller for Dexterous Motion Training or Assistance
    Cui, Xiang
    Chen, Weihai
    Jin, Xin
    Agrawal, Sunil K.
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2017, 22 (01) : 161 - 172
  • [4] Mechanical design and friction modelling of a cable-driven upper-limb exoskeleton
    Dezman, Miha
    Asfour, Tamim
    Ude, Ales
    Gams, Andrej
    [J]. MECHANISM AND MACHINE THEORY, 2022, 171
  • [5] Development and testing of stiffness model for pneumatic artificial muscle
    Doumit, Marc
    Leclair, Justin
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2017, 120 : 30 - 41
  • [6] Repetitive Task Training for After Improving Functional Ability After Stroke
    French, Beverley
    Thomas, Lois H.
    Leathley, Michael J.
    Sutton, Christopher J.
    McAdam, Joanna
    Forster, Anne
    Langhorne, Peter
    Price, Christopher I. M.
    Walker, Andrew
    Watkins, Caroline L.
    [J]. STROKE, 2009, 40 (04) : E98 - E99
  • [7] Developments in hardware systems of active upper-limb exoskeleton robots: A review
    Gopura, R. A. R. C.
    Bandara, D. S. V.
    Kiguchi, Kazuo
    Mann, G. K. I.
    [J]. ROBOTICS AND AUTONOMOUS SYSTEMS, 2016, 75 : 203 - 220
  • [8] Gouttefarde M, 2009, DETC 2008: 32ND ANNUAL MECHANISMS AND ROBOTICS CONFERENCE, VOL. 2, PTS A & B, P21
  • [9] A Review on Design of Upper Limb Exoskeletons
    Gull, Muhammad Ahsan
    Bai, Shaoping
    Bak, Thomas
    [J]. ROBOTICS, 2020, 9 (01)
  • [10] Human-robot cooperative control system based on serial elastic actuator bowden cable drive in ExoArm 7-DOF upper extremity exoskeleton
    Herbin, Pawel
    Pajor, Miroslaw
    [J]. MECHANISM AND MACHINE THEORY, 2021, 163