Self-assessment of Visual Acuity Using a Smartphone Application

被引:0
|
作者
Kim, Sejung [1 ]
Kim, Yuhyun [1 ]
Oh, Minkyung [2 ]
Moon, Sunghyuk [1 ,3 ]
机构
[1] Inje Univ, Busan Paik Hosp, Dept Ophthalmol, Coll Med, 75 Bokji Ro, Busan 47392, South Korea
[2] Inje Univ, Coll Med, Dept Pharmacol, Busan, South Korea
[3] TI Inc, Goyang, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2024年 / 65卷 / 06期
关键词
Examination; Korean; Mobile application; Visual acuity;
D O I
10.3341/jkos.2024.65.6.378
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We evaluated the accuracy and usefulness of self -assessment of visual acuity (VA) using a smartphone application for Korean users and explored its potential application in screening eye diseases. Methods: In total, 52 participants aged >= 20 years were included in the study. Of these participants, 31 used Jin Yong-Han's VA chart and the smartphone application to measure their distant visual acuity (DVA), whereas 21 used Han Chun-Seok's near visual acuity chart and the application to measure their near visual acuity (NVA). The results and time required for VA measurement using both methods were compared. VA was converted to logarithm of the minimum angle of resolution (logMAR) for analysis. The voice recognition rate of the application for numbers 2-9 was assessed. Results: The mean NVA was 0.29 +/- 0.28 using Han's chart and 0.30 +/- 0.43 using the application with no significant difference ( p = 1.00). The mean DVA was 0.19 +/- 5.89 using Jin's chart and 0.20 +/- 0.27 using the application with no significant difference ( p = 0.19). The average time spent for measuring NVA and DVA was 19 seconds (s) using Han's and Jin's charts, whereas it was 42 and 38 s for measuring NVA and DVA using the application. The voice recognition rate of the application was 87% on average for numbers 2-9, with the highest rate for number 7 (79%) and the lowest rate for number 4 (91%). Conclusions: Self -assessment of VA using a smartphone application exhibited similar results to conventional VA measurement methods. Although the measurement time varied, DVA and NVA could be measured at home using a smartphone, and would be particularly useful for those who have difficulty visiting a hospital. J Korean Ophthalmol Soc 2024;65(6):378-385
引用
收藏
页码:378 / 385
页数:8
相关论文
共 50 条
  • [41] Real-time, precise, rapid and objective visual acuity assessment by self-adaptive step SSVEPs
    Zheng, Xiaowei
    Xu, Guanghua
    Du, Chenghang
    Yan, Wenqiang
    Tian, Peiyuan
    Zhang, Kai
    Liang, Renghao
    Han, Chengcheng
    Zhang, Sicong
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (04)
  • [42] Quantitative assessment of visual acuity in projective head mounted displays
    Fidopiastis, C
    Meyer, C
    Fuhrman, C
    Rolland, J
    HELMET- AND HEAD-MOUNTED DISPLAYS VIII: TECHNOLOGIES AND APPLICATIONS, 2003, 5079 : 399 - 406
  • [43] Dynamic Visual Acuity in the Peripheral Visual Field Using Gabor Patches
    Lewis, P. R.
    Rosen, R.
    Gustafsson, J.
    Carius, S.
    Unsbo, P.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [44] Visual acuity and contrast sensitivity screening with a new iPad application
    Rodriguez-Vallejo, Manuel
    Llorens-Quintana, Clara
    Furlan, Walter D.
    Monsoriu, Juan A.
    DISPLAYS, 2016, 44 : 15 - 20
  • [45] Self-Assessment of Comprehensibility and Accentedness in Second Language Korean
    Isbell, Daniel R.
    Lee, Junkyu
    LANGUAGE LEARNING, 2022, 72 (03) : 806 - 852
  • [46] Repeatability of visual acuity testing using a psychometric function
    Tokutake, Tomoki
    Yamauchi, Tomofusa
    Mita, Norihiro
    Kawamoto, Ken-ichiro
    Tabuchi, Hitoshi
    Kani, Kazutaka
    Hara, Heihachiro
    Tabuchi, Akio
    Sasaki, Hiroshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2014, 58 (04) : 381 - 387
  • [47] Unveiling Visual Acuity in 58,712 Four-Year-Olds: Standardized Assessment Defined Normative Visual Acuity Threshold
    Bjelos, Mirjana
    Busic, Mladen
    Rak, Benedict
    Curic, Ana
    Elabjer, Biljana Kuzmanovic
    VISION, 2024, 8 (02)
  • [48] Repeatability of visual acuity testing using a psychometric function
    Tomoki Tokutake
    Tomofusa Yamauchi
    Norihiro Mita
    Ken-ichiro Kawamoto
    Hitoshi Tabuchi
    Kazutaka Kani
    Heihachiro Hara
    Akio Tabuchi
    Hiroshi Sasaki
    Japanese Journal of Ophthalmology, 2014, 58 : 381 - 387
  • [49] Temporal perceptual coding using a visual acuity model
    Adzic, Velibor
    Cohen, Robert A.
    Vetro, Anthony
    HUMAN VISION AND ELECTRONIC IMAGING XIX, 2014, 9014
  • [50] A novel smartphone App to support the clinical practice of pediatric ophthalmology and strabismus: the validation of visual acuity tests
    Elisabetta Racano
    Giulia Malfatti
    Riccardo Pertile
    Roberta Delle Site
    Federica Romanelli
    Andrea Nicolini
    European Journal of Pediatrics, 2023, 182 : 4007 - 4013