Self-assessment of Visual Acuity Using a Smartphone Application

被引:0
|
作者
Kim, Sejung [1 ]
Kim, Yuhyun [1 ]
Oh, Minkyung [2 ]
Moon, Sunghyuk [1 ,3 ]
机构
[1] Inje Univ, Busan Paik Hosp, Dept Ophthalmol, Coll Med, 75 Bokji Ro, Busan 47392, South Korea
[2] Inje Univ, Coll Med, Dept Pharmacol, Busan, South Korea
[3] TI Inc, Goyang, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2024年 / 65卷 / 06期
关键词
Examination; Korean; Mobile application; Visual acuity;
D O I
10.3341/jkos.2024.65.6.378
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We evaluated the accuracy and usefulness of self -assessment of visual acuity (VA) using a smartphone application for Korean users and explored its potential application in screening eye diseases. Methods: In total, 52 participants aged >= 20 years were included in the study. Of these participants, 31 used Jin Yong-Han's VA chart and the smartphone application to measure their distant visual acuity (DVA), whereas 21 used Han Chun-Seok's near visual acuity chart and the application to measure their near visual acuity (NVA). The results and time required for VA measurement using both methods were compared. VA was converted to logarithm of the minimum angle of resolution (logMAR) for analysis. The voice recognition rate of the application for numbers 2-9 was assessed. Results: The mean NVA was 0.29 +/- 0.28 using Han's chart and 0.30 +/- 0.43 using the application with no significant difference ( p = 1.00). The mean DVA was 0.19 +/- 5.89 using Jin's chart and 0.20 +/- 0.27 using the application with no significant difference ( p = 0.19). The average time spent for measuring NVA and DVA was 19 seconds (s) using Han's and Jin's charts, whereas it was 42 and 38 s for measuring NVA and DVA using the application. The voice recognition rate of the application was 87% on average for numbers 2-9, with the highest rate for number 7 (79%) and the lowest rate for number 4 (91%). Conclusions: Self -assessment of VA using a smartphone application exhibited similar results to conventional VA measurement methods. Although the measurement time varied, DVA and NVA could be measured at home using a smartphone, and would be particularly useful for those who have difficulty visiting a hospital. J Korean Ophthalmol Soc 2024;65(6):378-385
引用
收藏
页码:378 / 385
页数:8
相关论文
共 50 条
  • [31] Pattern visual evoked potentials in the assessment of objective visual acuity in amblyopic children
    Gundogan F.C.
    Mutlu F.M.
    Altinsoy H.I.
    Tas A.
    Oz O.
    Sobaci G.
    International Ophthalmology, 2010, 30 (4) : 377 - 383
  • [32] Dice test - a simple method for assessment of visual acuity in infants with visual deficits
    Rohrschneider, K.
    Brill, B.
    Bayer, Y.
    Ahrens, P.
    OPHTHALMOLOGE, 2010, 107 (07): : 641 - 646
  • [33] Using wavefront measurements to predict visual acuity
    Dai, GM
    OPHTHALMIC TECHNOLOGIES XIV, 2004, 5314 : 220 - 228
  • [34] VISUAL-ACUITY ASSESSMENT FROM BIRTH TO 3 YEARS USING THE ACUITY CARD PROCEDURE - CROSS-SECTIONAL AND LONGITUDINAL SAMPLES
    COURAGE, ML
    ADAMS, RJ
    OPTOMETRY AND VISION SCIENCE, 1990, 67 (09) : 713 - 718
  • [35] ASSESSMENT OF VISUAL-ACUITY IN CHILDREN WITH TRISOMY-18
    HOLMES, JM
    COATES, CM
    OPHTHALMIC GENETICS, 1994, 15 (3-4): : 115 - 120
  • [36] Computer-based assessment of visual acuity - Technical realization
    Hoffmann, A
    Menozzi, M
    BIOMEDIZINISCHE TECHNIK, 1997, 42 (03): : 55 - 60
  • [37] Evaluation of Single Pixel Step Sizes in Visual Acuity Assessment
    Toole, Andrew J.
    Raasch, Thomas W.
    Fogt, Nick
    Brunstetter, Tyson J.
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (02) : 244 - 250
  • [38] Assessment of cataract surgery in rural India - Visual acuity outcome
    Murthy, GVS
    Gupta, SK
    Talwar, D
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1996, 74 (01): : 60 - 63
  • [39] Screening for myopia and refractive errors using LogMAR visual acuity by optometrists and a simplified visual acuity chart by nurses
    Tong, L
    Saw, SM
    Chan, ESY
    Yap, M
    Lee, HY
    Kwang, YP
    Tan, D
    OPTOMETRY AND VISION SCIENCE, 2004, 81 (09) : 684 - 691
  • [40] Visual self-assessment with the ACTO test during follow-up of AMD patients after intravitreal injections
    Cordes, A.
    Strobel, A.
    Meyer, C. H.
    Ender, F.
    Schrage, N.
    OPHTHALMOLOGE, 2009, 106 (09): : 775 - 782