Self-assessment of Visual Acuity Using a Smartphone Application

被引:0
|
作者
Kim, Sejung [1 ]
Kim, Yuhyun [1 ]
Oh, Minkyung [2 ]
Moon, Sunghyuk [1 ,3 ]
机构
[1] Inje Univ, Busan Paik Hosp, Dept Ophthalmol, Coll Med, 75 Bokji Ro, Busan 47392, South Korea
[2] Inje Univ, Coll Med, Dept Pharmacol, Busan, South Korea
[3] TI Inc, Goyang, South Korea
来源
JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | 2024年 / 65卷 / 06期
关键词
Examination; Korean; Mobile application; Visual acuity;
D O I
10.3341/jkos.2024.65.6.378
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We evaluated the accuracy and usefulness of self -assessment of visual acuity (VA) using a smartphone application for Korean users and explored its potential application in screening eye diseases. Methods: In total, 52 participants aged >= 20 years were included in the study. Of these participants, 31 used Jin Yong-Han's VA chart and the smartphone application to measure their distant visual acuity (DVA), whereas 21 used Han Chun-Seok's near visual acuity chart and the application to measure their near visual acuity (NVA). The results and time required for VA measurement using both methods were compared. VA was converted to logarithm of the minimum angle of resolution (logMAR) for analysis. The voice recognition rate of the application for numbers 2-9 was assessed. Results: The mean NVA was 0.29 +/- 0.28 using Han's chart and 0.30 +/- 0.43 using the application with no significant difference ( p = 1.00). The mean DVA was 0.19 +/- 5.89 using Jin's chart and 0.20 +/- 0.27 using the application with no significant difference ( p = 0.19). The average time spent for measuring NVA and DVA was 19 seconds (s) using Han's and Jin's charts, whereas it was 42 and 38 s for measuring NVA and DVA using the application. The voice recognition rate of the application was 87% on average for numbers 2-9, with the highest rate for number 7 (79%) and the lowest rate for number 4 (91%). Conclusions: Self -assessment of VA using a smartphone application exhibited similar results to conventional VA measurement methods. Although the measurement time varied, DVA and NVA could be measured at home using a smartphone, and would be particularly useful for those who have difficulty visiting a hospital. J Korean Ophthalmol Soc 2024;65(6):378-385
引用
收藏
页码:378 / 385
页数:8
相关论文
共 50 条
  • [21] Comparison of Visual Acuity Measurement Using Three Methods: Standard ETDRS Chart, Near Chart and a Smartphone-Based Eye Chart Application
    Tiraset, Nanida
    Poonyathalang, Anuchit
    Padungkiatsagul, Tanyatuth
    Deeyai, Montakarn
    Vichitkunakorn, Polathep
    Vanikieti, Kavin
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 859 - 869
  • [22] Estimating visual acuity by character counting using the Snellen visual acuity chart
    Levy, AH
    McCulley, TJ
    Lam, BL
    Feuer, WJ
    EYE, 2005, 19 (06) : 622 - 624
  • [23] Estimating visual acuity by character counting using the Snellen visual acuity chart
    A H Levy
    T J McCulley
    B L Lam
    W J Feuer
    Eye, 2005, 19 : 622 - 624
  • [24] Behavioral assessment of visual acuity in mice and rats
    Prusky, GT
    West, PWR
    Douglas, RM
    VISION RESEARCH, 2000, 40 (16) : 2201 - 2209
  • [25] Measuring visual acuity and spherical refraction with smartphone screens emitting blue light
    Salmeron-Campillo, Rosa Maria
    Varona-Gomez, Felix Tomas
    Ogino, Mari
    Hunter, Stephen
    Hussey, Vincent
    Suh, Donny W.
    Gore, Rujuta
    Jaskulski, Mateusz
    Lopez-Gil, Norberto
    JOURNAL OF OPTOMETRY, 2024, 17 (01)
  • [26] Measuring the impact of suppression on visual acuity in children with amblyopia using a dichoptic visual acuity chart
    Zhu, Bixia
    Liao, Meng
    Liu, Longqian
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [27] Comparison of Snellen Visual Acuity Measurements in Retinal Clinical Practice to Electronic ETDRS Protocol Visual Acuity Assessment
    Baker, Carl W.
    Josic, Kristin
    Maguire, Maureen G.
    Jampol, Lee M.
    Martin, Daniel F.
    Rofagha, Soraya
    Sun, Jennifer K.
    DRCR Retina Network
    OPHTHALMOLOGY, 2023, 130 (05) : 533 - 541
  • [28] Lea symbols: visual acuity assessment and detection of amblyopia
    M. H. Gräf
    R. Becker
    H. Kaufmann
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2000, 238 : 53 - 58
  • [29] Functional Visual Acuity Assessment of Severe Atopic Keratoconjunctivitis
    Ibrahim, Osama M. A.
    Dogru, Murat
    Kaido, Minako
    Kojima, Takashi
    Fujishima, Hiroshi
    Tsubota, Kazuo
    CORNEA, 2014, 33 : S13 - S18
  • [30] Assessment of Peripheral Visual Acuity in Different Test Conditions
    Belokopytov A.V.
    Rozhkova G.I.
    Gracheva M.A.
    Neuroscience and Behavioral Physiology, 2022, 52 (5) : 747 - 756