Fault-tolerant strategies in MMC-based high power magnet supply for particle accelerator

被引:2
作者
Moratalla, Manuel Colmenero [1 ]
Vidal-Albalate, Ricardo [2 ]
Delgado, Francisco R. Blanquez [1 ]
Blasco-Gimenez, Ramon [3 ]
机构
[1] CERN European Org Nucl Res, 1 Esplanade Particules, CH-1217 Meyrin, Switzerland
[2] Univ Jaume I Castellon, Ave Vicent Sos Baynat S-N, Castellon De La Plana 12071, Spain
[3] Univ Politecn Valencia, Camino Vera S-N, Valencia 46022, Spain
关键词
Modular multilevel converters; High power converter; Particle accelerator; Reliability; Protection; MODULAR MULTILEVEL CONVERTER;
D O I
10.1016/j.matcom.2023.07.014
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Many particle accelerators require to supply chains of magnets with high quality, high magnitude, cycling currents. To do this, the power converters need to provide high output voltages, reaching in some cases tens of kilovolts. Additionally, converters are required to store the magnet energy during de-magnetization cycles. For such application, Full-bridge Modular Multilevel Converters (FB-MMC) could be used given their capacity to store energy and their inherent reliability. In this sense, one of the most interesting features of the proposed topology is the possibility of bypassing one or several submodules in the event of a fault or malfunction. By doing this, it is possible to ride-through the failure of a component and avoid the interruption of the accelerator operation. However, when the number of submodules is small, this operation could lead to an excessive charge of the healthy cells, increasing the risk of secondary failures. Besides, undesired harmonic content could appear on the output current, degrading the operation of the accelerator. It is then necessary to implement strategies that allow to remove a faulty cell without significantly impacting the operation of the remaining ones and of the converter itself. Accordingly, the purpose of this article is to investigate several of these strategies and assess them. By means of detailed computer simulations, the behaviour of the converter during normal and submodule fault conditions is analysed. Then, several fault-tolerant strategies are described, verified and compared with the aid of simulation tools. The results show the effectiveness of the analysed strategies in avoiding the overvoltage on the healthy submodules after a cell bypass and the little impact of this operation on the quality of the converter output current. (c) 2023 The Author(s). Published by Elsevier B.V. on behalf of International Association for Mathematics and Computers in Simulation (IMACS). This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:63 / 79
页数:17
相关论文
共 21 条
  • [1] FCC-ee: The Lepton Collider: Future Circular Collider Conceptual Design Report Volume 2
    Abada, A.
    Abbrescia, M.
    AbdusSalam, S. S.
    Abdyukhanov, I.
    Fernandez, J. Abelleira
    Abramov, A.
    Aburaia, M.
    Acar, A. O.
    Adzic, P. R.
    Agrawal, P.
    Aguilar-Saavedra, J. A.
    Aguilera-Verdugo, J. J.
    Aiba, M.
    Aichinger, I.
    Aielli, G.
    Akay, A.
    Akhundov, A.
    Aksakal, H.
    Albacete, J. L.
    Albergo, S.
    Alekou, A.
    Aleksa, M.
    Aleksan, R.
    Fernandez, R. M. Alemany
    Alexahin, Y.
    Alia, R. G.
    Alioli, S.
    Tehrani, N. Alipour
    Allanach, B. C.
    Allport, P. P.
    Altinli, M.
    Altmannshofer, W.
    Ambrosio, G.
    Amorim, D.
    Amstutz, O.
    Anderlini, L.
    Andreazza, A.
    Andreini, M.
    Andriatis, A.
    Andris, C.
    Andronic, A.
    Angelucci, M.
    Antinori, F.
    Antipov, S. A.
    Antonelli, M.
    Antonello, M.
    Antonioli, P.
    Antusch, S.
    Anulli, F.
    Apolinario, L.
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2019, 228 (02) : 261 - 623
  • [2] Robust and Generic Control of Full-Bridge Modular Multilevel Converter High-Voltage DC Transmission Systems
    Adam, Grain Philip
    Davidson, Innocent Ewean
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (06) : 2468 - 2476
  • [3] Alharbi M., 2018, 2018 IEEE Electronic Power Grid (eGrid), P1, DOI DOI 10.1109/EGRID.2018.8598662
  • [4] Boattini Fulvio, 2015, 2015 17th European Conference on Power Electronics and Applications (EPE'15 ECCE-Europe), P1, DOI 10.1109/EPE.2015.7309267
  • [5] INELFE: main description and operational experience over three years in service
    Coronado, L.
    Longas, C.
    Rivas, R.
    Sanz, S.
    Bola, J.
    Junco, P.
    Perez, G.
    [J]. 2019 AEIT HVDC INTERNATIONAL CONFERENCE (AEIT HVDC): OPERATIONAL EXPERIENCE AND TECHNOLOGICAL DEVELOPMENT FOR APPLICATION WORLDWIDE, 2019,
  • [6] Operation, Control, and Applications of the Modular Multilevel Converter: A Review
    Debnath, Suman
    Qin, Jiangchao
    Bahrani, Behrooz
    Saeedifard, Maryam
    Barbosa, Peter
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (01) : 37 - 53
  • [7] Overview on submodule topologies, modeling, modulation, control schemes, fault diagnosis, and tolerant control strategies of modular multilevel converters
    Deng F.
    Lü Y.
    Liu C.
    Heng Q.
    Yu Q.
    Zhao J.
    [J]. Chinese Journal of Electrical Engineering, 2020, 6 (01): : 1 - 21
  • [8] Grahame H.D, 2003, Pulse Width Modulation for Power Converters: Principles and Practice
  • [9] An Improved CPS-PWM Method for Modular Multilevel Converter
    Huang, Yu
    Liu, Zhenxing
    Dian, Renjun
    Huang, Pei
    Wang, Peng
    [J]. PROCEEDINGS OF THE 33RD CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2021), 2021, : 7311 - 7317
  • [10] Lesnicar A., 2003, P IEEE BOL POW TECH, V3, P272