Tribocorrosion experimental investigation on Ti6Al4V burnished samples used for hip joint replacement

被引:1
作者
Sicilia, Alessandro [1 ]
Saffioti, Maria Rosaria [2 ]
Miorin, Enrico [3 ]
Zin, Valentina [3 ]
Ruggiero, Alessandro [1 ]
Umbrello, Domenico [2 ]
机构
[1] Univ Salerno, Dept Ind Engn, Via Giovanni Paolo II 132, I-84084 Fisciano, Italy
[2] Univ Calabria, Dept Mech Energy & Management Engn, Arcavacata Di Rende, Italy
[3] Natl Res Council Italy CNR, Inst Condensed Matter Chem & Technol Energy ICMATE, Padua, Italy
关键词
tribocorrosion; wear; friction; experiments; burnishing; Ti6Al4V; hip replacement; biotribology; FRETTING-CORROSION;
D O I
10.1177/17515831241262676
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
This work aimed to investigate the effect of the burnishing surface treatment on the tribocorrosion resistance related to Ti6Al4V specimens, in the framework of the head-neck tribo-pair characterising a total hip replacement. The experimental procedure carried out started by choosing the specimens referred to different burnishing conditions together with specimens not treated or treated only with the turning process. Then, tribocorrosion experiments with fixed load and two frequencies were conducted through a reciprocating tribometer equipped with a potentiostat able to measure the electrochemical corrosion potential and current associated to the synergistic wear phenomenon analysed together with the coefficient of friction. Furthermore, optical topographical acquisitions were performed before and after the experiments. The results showed that the non-burnished specimens exhibited unexpected oscillations of the coefficient of friction approximately in the middle of the rubbing phase and the same happens for the cell potential; the wear volume was measured after the tribocorrosion test. This allowed to estimate the wear factor related to all the analysed configurations, showing a greater mean value in correspondence of greater sliding frequencies in the non-burnished cases, while the opposite happens in the burnished cases. Finally, the burnished sample at the lower burnishing force resulted to have the noblest corrosion potential, while the non-burnished samples exhibited the lowest corrosion current density.
引用
收藏
页码:133 / 142
页数:10
相关论文
共 29 条
  • [1] Ansari JS., 2018, ORTHOP TRAUMA, V32, P54, DOI DOI 10.1016/J.MPORTH.2017.11.010
  • [2] Correlation of surface integrity with processing parameters and advanced interface cooling/lubrication in burnishing of Ti-6Al-4V alloy
    Caudill, J.
    Schoop, J.
    Jawahir, I. S.
    [J]. ADVANCES IN MATERIALS AND PROCESSING TECHNOLOGIES, 2019, 5 (01) : 53 - 66
  • [3] Chang Justin S, 2020, J Clin Orthop Trauma, V11, P9, DOI 10.1016/j.jcot.2019.09.021
  • [4] Choroszynski M, 2017, BIO-ALGORITHMS MED-S, V13, P133, DOI 10.1515/bams-2017-0017
  • [5] State of the art of Deep Rolling
    Delgado, P.
    Cuesta, I. I.
    Alegre, J. M.
    Diaz, A.
    [J]. PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2016, 46 : 1 - 10
  • [6] Hip and knee replacement 1 Hip replacement
    Ferguson, Rory J.
    Palmer, Antony J. R.
    Taylor, Adrian
    Porter, Martyn L.
    Malchau, Henrik
    Glyn-Jones, Sion
    [J]. LANCET, 2018, 392 (10158) : 1662 - 1671
  • [7] Tribocorrosion properties of different type titanium alloys in simulated body fluid
    Hacisalihoglu, I.
    Samancioglu, A.
    Yildiz, F.
    Purcek, G.
    Alsaran, A.
    [J]. WEAR, 2015, 332 : 679 - 686
  • [8] Differences in the fretting corrosion of metal-metal and ceramic-metal modular junctions of total hip replacements
    Hallab, NJ
    Messina, C
    Skipor, A
    Jacobs, JJ
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (02) : 250 - 259
  • [9] Hornbach D., 2007, ASTM INT, V13580, P45
  • [10] Third-Generation Alumina-on-Alumina Total Hip Arthroplasty: 14 to 16-Year Follow-Up Study
    Kang, Bun-Jung
    Ha, Yong-Chan
    Ham, Dae-Woong
    Hwang, Sun-Chul
    Lee, Young-Kyun
    Koo, Kyung-Hoi
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (03) : 411 - 415