High-sensitivity liquid chromatography-tandem mass spectrometry quantitative for alkyl imidazolium ionic liquids in human serum: Advancing biomonitoring of human exposure concerns

被引:1
|
作者
Li, Ming [1 ]
Wu, Ziji [1 ]
Yu, Qingqing [1 ]
Fang, Min [1 ]
Liu, Xiaofang [2 ]
Cao, Wencheng [2 ]
Wen, Sheng [2 ]
Li, Jingguang [3 ,4 ]
Wu, Yongning [1 ,3 ,4 ]
Liu, Xin [1 ]
机构
[1] Wuhan Polytech Univ, Coll Food Sci & Engn, Key Lab Deep Proc Major Grain & Oil, Chinese Minist Educ, Wuhan 430023, Hubei, Peoples R China
[2] Hubei Prov Ctr Dis Control & Prevent, Wuhan 430079, Hubei, Peoples R China
[3] China Natl Ctr Food Safety Risk Assessment, NHC Key Lab Food Safety Risk Assessment, Beijing 100021, Peoples R China
[4] Chinese Acad Med Sci, Peking Union Med Coll, Dept Nutr & Food Safety, Res Unit Food Safety, Beijing 100021, Peoples R China
基金
中国国家自然科学基金;
关键词
Alkyl imidazolium compounds; Bioanalytical methods; Mass spectrometry; Solid -phase extraction; Human exposure; TOXICITY; EXTRACTION; BROMIDE; CATIONS; SAMPLES; IMPACT;
D O I
10.1016/j.talanta.2024.126257
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Alkyl imidazolium ionic liquids (Cn[MIM]), initially heralded as eco-friendly green solvents for diverse industrial applications, have increasingly been recognized fortheir biodegradability challenges and multiple biotoxicity. Despite potential health risks, research into the effects of Cn[MIM] on human health remains scarce, particularly regarding their detection in biological serum samples. This study validated a matrix-matched calibration quantitative method that utilizes solid-phase extraction (SPE) coupled with ultrahigh-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The method was used to analyze the presence of 10 ionic liquids (ILs) with varying alkyl carbon chain lengths (C2-C12) across 300 human serum samples. Efficient separation was achieved using optimized SPE conditions and a BEH C18 column with an appropriate mobile phase. Results demonstrated a strong linear relationship (0.05-100 ng/mL; R2 = 0.995-0.999), with detection and quantification limits with detection and quantification limits ranging from 0.001 to 0.107 ng/mL and 0.003-0.355 ng/mL, respectively. Intraday and inter-day precisions were 0.85-6.99 % and 1.50-7.46 %, with recoveries between 82 and 113 %. The validated method detected C6MIM in 19 % of samples and C8MIM in 8.3 % of samples, with concentrations ranging from 0.02 to 111.70 mu g/L and 0.09-16.99 mu g/L, respectively, suggesting a potential risk of human exposure. This underscores the importance of robust detection methods in monitoring environmental and human health impacts of alkyl imidazolium compounds.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Quantitative determination of lisinopril in human plasma by high performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Qin, Feng
    Wang, Dan
    Yang, Shuyan
    Jing, Lijuan
    Xiong, Zhili
    Li, Famei
    BIOMEDICAL CHROMATOGRAPHY, 2012, 26 (06) : 691 - 696
  • [42] Quantitative analysis of quazepam and its metabolites in human blood, urine, and bile by liquid chromatography-tandem mass spectrometry
    Zhou, Jing
    Yamaguchi, Koji
    Ohno, Youkichi
    FORENSIC SCIENCE INTERNATIONAL, 2014, 241 : E5 - E12
  • [43] Quantitative determination of ε-N-carboxymethyl-L-lysine in human plasma by liquid chromatography-tandem mass spectrometry
    Kuang, Liqing
    Jing, Zhiqiang
    Wang, Jing
    Ma, Liyuan
    Liu, Xiaoqiang
    Yang, Jin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 90 : 1 - 6
  • [44] Study of sample preparation for quantitative analysis of amino acids in human sweat by liquid chromatography-tandem mass spectrometry
    Delgado-Povedano, M. M.
    Calderon-Santiago, M.
    Priego-Capote, F.
    Luque de Castro, M. D.
    TALANTA, 2016, 146 : 310 - 317
  • [45] Determination of intact oxaliplatin in human plasma using high performance liquid chromatography-tandem mass spectrometry
    Zhang, Wenjiang
    Seymour, Lesley
    Chen, Eric X.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 876 (02): : 277 - 282
  • [46] Human Biomonitoring of Serum Polybrominated Diphenyl Ethers by Supported Liquid Extraction and Gas Chromatography Coupled With Tandem Mass Spectrometry
    Liu, Miao
    Jia, Xiangyu
    Peng, Rongfei
    Bai, Zhijun
    Yuan, Jun
    Tan, Lei
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (21)
  • [47] High Speed Separation of PFCs in Human Serum by C18-Monolithic Column Liquid Chromatography-Tandem Mass Spectrometry
    Lee, Won-Woong
    Lee, Sun-Young
    Yu, Se Mi
    Hong, Jongki
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (11): : 3727 - 3734
  • [48] A rapid and simple liquid chromatography-tandem mass spectrometry method for the measurement of testosterone, androstenedione, and dehydroepiandrosterone in human serum
    Xu, Wenjuan
    Li, Huijun
    Guan, Qing
    Shen, Ying
    Cheng, Liming
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2017, 31 (05)
  • [49] Validation of a Multiresidue Analysis Method for 379 Pesticides in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry
    Shin, Yongho
    Lee, Jonghwa
    Lee, Jiho
    Lee, Junghak
    Kim, Eunhye
    Liu, Kwang-Hyeon
    Lee, Hye Suk
    Kim, Jeong-Han
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (13) : 3550 - 3560
  • [50] Determination of cortisol and cortisone in human saliva by a liquid chromatography-tandem mass spectrometry method
    Henriques Vieira, Jose Gilberto
    Nakamura, Odete Hirata
    Carvalho, Valdemir Melechko
    ARQUIVOS BRASILEIROS DE ENDOCRINOLOGIA E METABOLOGIA, 2014, 58 (08) : 844 - 850