Application Potential of a Dew-Point Cooling Tower in Selected Energy Intensive Applications in Temperate Climate

被引:2
作者
Pandelidis, Demis [1 ]
Matuszczak, Mikolaj [2 ]
Krowicki, Pawel [3 ]
Poskart, Bartosz [3 ]
Iskierka, Grzegorz [3 ]
Worek, William [4 ]
Cetin, Sabri [5 ]
机构
[1] Wroclaw Univ Sci & Technol, Dept Mech & Power Engn, 27 Wyspianski Str, PL-50370 Wroclaw, Poland
[2] Wroclaw Univ Sci & Technol, Dept Environm Engn, 27 Wyspianski Str, PL-50370 Wroclaw, Poland
[3] Wroclaw Univ Sci & Technol, Dept Mech Engn, 27 Wyspianski Str, PL-50370 Wroclaw, Poland
[4] Argonne Natl Lab, 9700 S Cass Ave, Lemont, IL 60439 USA
[5] Univ Illinois, Dept Mech & Ind Engn, Chicago, IL 60607 USA
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 17期
关键词
cooling tower; renewable energy; energy efficiency; dew-point cooling;
D O I
10.3390/app14177605
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In the article, the application potential of the dew-point cooling tower (DPCT) in selected energy-intensive applications in temperate climates was analyzed and discussed. The applications selected for analysis are power generation with natural gas turbines and chilled water air conditioning systems. The study is based on a mathematical model derived from a modified epsilon-NTU model. The model was validated against experimental results and showed satisfactory agreement with the experimental data. DPCT was compared with a typical cooling tower limited by the wet-bulb temperature (wet-bulb cooling tower, WBCT). The simulation results showed that DPCT is able to provide significant energy savings in energy-intensive applications; therefore, its application potential in temperate climates can be considered justified. In the case of gas turbines, DPCT was able to generate 2 to 10 percentage points more capacity than operating on outdoor air and 1.8 to 5 percentage points more than operating with WBCT. In the case of air conditioning systems, the system equipped with DPCT achieved EERs (energy efficiency ratios) higher by 1 to 7.2 compared to dry cooling and by 0.3 to 5.1 compared to systems equipped with WBCT. The annual energy savings obtained by the system with DPCT were 14.7 MWh compared to WBCT and 30 MWh compared to dry cooling.
引用
收藏
页数:19
相关论文
共 21 条
[1]  
Al-Anfaji A.S.B., 2014, Ph.D. Thesis
[2]   Systematic analysis with comparison of a chiller plant with horizontal underground heat exchangers and cooling tower [J].
Al-qazzaza, Ameer Hussein Shakir ;
Farzaneh-Gorda, Mahmood ;
Niazmand, Hamid .
JOURNAL OF BUILDING ENGINEERING, 2024, 92
[3]  
Anisimov S, 2014, PROCEEDINGS OF THE ASME POWER CONFERENCE, 2014, VOL 2
[4]  
[Anonymous], 2024, Trading and Economics Poland-Electricity Prices
[5]  
[Anonymous], 2024, Trading and Economics EU Natural Gas TT
[6]   Investigation of the simultaneous effect of fouling and ambient conditions on cooling performance and water consumption of a wet cooling tower [J].
Arefimanesh, Ali ;
Heyhat, Mohammad Mahdi .
CASE STUDIES IN THERMAL ENGINEERING, 2024, 58
[7]   Analytical Investigation of a Novel System for Combined Dew Point Cooling and Water Recovery [J].
Cichon, Aleksandra ;
Worek, William .
APPLIED SCIENCES-BASEL, 2021, 11 (04) :1-18
[8]  
IEA, 2018, The Future of Cooling
[9]   Thermo-economic analysis of the impact of the interaction between two neighboring dry cooling towers on power generation of dual thermal power units and the energy-efficient operation strategy [J].
Ma, Huan ;
Cai, Liang ;
Si, Fengqi .
APPLIED THERMAL ENGINEERING, 2024, 240
[10]  
Pandelidis D., 2015, Ph.D. Thesis