Uncertainty Quantification in SAR Induced by Ultra-High-Field MRI RF Coil via High-Dimensional Model Representation

被引:3
作者
Wang, Xi [1 ]
Huang, Shao Ying [2 ]
Yucel, Abdulkadir C. [1 ]
机构
[1] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[2] Singapore Univ Technol & Design, Engn Prod Dev Dept, Singapore 487372, Singapore
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 07期
关键词
generalized polynomial chaos (gPC); high-dimensional model representation (HDMR); magnetic resonance imaging (MRI); MRI safety; sensitivity analysis; surrogate model; ultra-high-field (UHF) MRI; uncertainty quantification;
D O I
10.3390/bioengineering11070730
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
As magnetic field strength in Magnetic Resonance Imaging (MRI) technology increases, maintaining the specific absorption rate (SAR) within safe limits across human head tissues becomes challenging due to the formation of standing waves at a shortened wavelength. Compounding this challenge is the uncertainty in the dielectric properties of head tissues, which notably affects the SAR induced by the radiofrequency (RF) coils in an ultra-high-field (UHF) MRI system. To this end, this study introduces a computational framework to quantify the impacts of uncertainties in head tissues' dielectric properties on the induced SAR. The framework employs a surrogate model-assisted Monte Carlo (MC) technique, efficiently generating surrogate models of MRI observables (electric fields and SAR) and utilizing them to compute SAR statistics. Particularly, the framework leverages a high-dimensional model representation technique, which constructs the surrogate models of the MRI observables via univariate and bivariate component functions, approximated through generalized polynomial chaos expansions. The numerical results demonstrate the efficiency of the proposed technique, requiring significantly fewer deterministic simulations compared with traditional MC methods and other surrogate model-assisted MC techniques utilizing machine learning algorithms, all while maintaining high accuracy in SAR statistics. Specifically, the proposed framework constructs surrogate models of a local SAR with an average relative error of 0.28% using 289 simulations, outperforming the machine learning-based surrogate modeling techniques considered in this study. Furthermore, the SAR statistics obtained by the proposed framework reveal fluctuations of up to 30% in SAR values within specific head regions. These findings highlight the critical importance of considering dielectric property uncertainties to ensure MRI safety, particularly in 7 T MRI systems.
引用
收藏
页数:20
相关论文
共 51 条
[1]  
[Anonymous], 2010, Medical electrical equipment-Part 2-33: particular requirements for the basic safety and essential performance of magnetic resonance equipment for diagnosis, IEC60601-2-33
[2]  
[Anonymous], 2019, IEEE Std C95.1TM-2019
[3]   Clinical 7 T MRI: Are we there yet? A review about magnetic resonance imaging at ultra-high field [J].
Barisano, Giuseppe ;
Sepehrband, Farshid ;
Ma, Samantha ;
Jann, Kay ;
Cabeen, Ryan ;
Wang, Danny J. ;
Toga, Arthur W. ;
Law, Meng .
BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1094)
[4]   Stochastic finite element: a non intrusive approach by regression [J].
Berveiller, Marc ;
Sudret, Bruno ;
Lemaire, Maurice .
EUROPEAN JOURNAL OF COMPUTATIONAL MECHANICS, 2006, 15 (1-3) :81-92
[5]  
Brown R. W., 2014, Magnetic resonance imaging:physical principles and sequence design, V2nd
[6]   An algorithm for computations of the power deposition in human tissue [J].
Caputa, K ;
Okoniewski, M ;
Stuchly, MA .
IEEE ANTENNAS AND PROPAGATION MAGAZINE, 1999, 41 (04) :102-107
[7]   An Approach to Rapid Calculation of Temperature Change in Tissue Using Spatial Filters to Approximate Effects of Thermal Conduction [J].
Carluccio, Giuseppe ;
Erricolo, Danilo ;
Oh, Sukhoon ;
Collins, Christopher M. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (06) :1735-1741
[8]   Application of Different Methods to Quantify Uncertainty in Specific Absorption Rate Calculation Using a CAD-Based Mobile Phone Model [J].
Cheng, Xi ;
Monebhurrun, Vikass .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2017, 59 (01) :14-23
[9]   High dimensional model representation for stochastic finite element analysis [J].
Chowdhury, R. ;
Adhikari, S. .
APPLIED MATHEMATICAL MODELLING, 2010, 34 (12) :3917-3932
[10]   Calculation of Radiofrequency Electromagnetic Fields and Their Effects in MRI of Human Subjects [J].
Collins, Christopher M. ;
Wang, Zhangwei .
MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) :1470-1482