Detection of partial discharge patterns in hybrid high voltage power transmission lines based on parallel recognition method

被引:0
|
作者
Yang, Yang [1 ]
Wu, Yongye [2 ]
Gao, Yifei [3 ]
Huang, Yixuan [4 ]
Liu, Shukun [5 ]
Wang, Yuanshi [6 ]
机构
[1] Xihua Univ, Chengdu, Peoples R China
[2] State Grid Sichuan Elect Power Co, Chengdu Power Supply Co, Chengdu, Peoples R China
[3] Chongqing Univ Posts & Telecommun, Chongqing, Peoples R China
[4] Queen Mary Univ London, London, England
[5] Nanyang Technol Univ, Nanyang, Singapore
[6] Univ Sheffield, Sheffield, England
关键词
Hybrid high-voltage power transmission lines; BPNN; Partial discharge; Dung beetle optimization algorithm; Orthogonal contrastive learning; ALGORITHM;
D O I
10.7717/peerj-cs.2045
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Due to their specially designed structures, the partial discharge detection of hybrid highvoltage power transmission lines (HHVPTL) composed of overhead lines and power cables has made it difficult to monitor the conditions of power transmission lines. A parallel recognition method for partial discharge patterns of HHVPTLs is proposed by implementing wavelet analysis and improved backpropagation neural network (BPNN) to address the shortcomings of low efficiency, poor accuracy, and inability to parallel analysis of current partial discharge (PD) detection algorithms for HHVPTLs. Firstly, considering the non -smoothness of the partial discharge of the HHVPTLs, the wavelet packet decomposition algorithm is implemented to decompose the PD of the HHVPTL and resolve the relevant signal indicators to form the attribute vectors. Then, BPNN is implemented as a classification model. A beetle optimization (DBO) algorithm based on orthogonal contrastive learning improvement is introduced to optimize the BPNN parameters since BPNN has a slow convergence problem and fails easily into a local optimum. The proposed IDBO-BPNN is employed as the model that recognizes and analyzes the parallel partial discharge patterns of HHVPTLs. Finally, the suggested model is implemented to investigate the local discharge data of an HHVPTL in the Kaggle Featured Prediction Competition and is compared with other algorithms. The experimental results indicate that the proposed model can more accurately identify whether PDs occur in an HHVPTL and detect phases where PDs occur, with higher overall accuracy and efficiency. An excellent practical performance is achieved. The proposed model can achieve the recognition accuracy of 95.5%, which is 5.3333% higher than that of the DBO-BPNN and far more than other recognition algorithms.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Detection of partial discharge patterns in hybrid high voltage power transmission lines based on parallel recognition method
    Yang Y.
    Wu Y.
    Gao Y.
    Huang Y.
    Liu S.
    Wang Y.
    PeerJ Computer Science, 2024, 10
  • [2] Recognition of Fused Partial Discharge Patterns in High Voltage Insulation Systems: A Hybrid DCNN and SVM Based Approach
    Devi, I. Aruna
    Maheswari, R., V
    Rajesh, R.
    IETE JOURNAL OF RESEARCH, 2023, 69 (10) : 7553 - 7568
  • [3] A Novel Partial Discharge Detection Algorithm in Power Transmission Lines Based on Deep Learning
    Ding, Benxiang
    Zhu, Hongwei
    2021 3RD INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS (SPIES 2021), 2021, : 100 - 104
  • [4] A novel extension neural network based partial discharge pattern recognition method for high-voltage power apparatus
    Chen, Hung-Cheng
    Gu, Feng-Chang
    Wang, Meng-Hui
    EXPERT SYSTEMS WITH APPLICATIONS, 2012, 39 (03) : 3423 - 3431
  • [5] Partial Discharge Pattern Recognition of High Voltage Cables Based on the Stacked Denoising Autoencoder Method
    Wang Ganjun
    Yang Fan
    Peng Xiaosheng
    Wu Yijiang
    Liu Taiwei
    Li Zibo
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3778 - 3782
  • [6] Partial Discharge Patterns in High Voltage Insulation
    Illias, Hazlee
    Yuan, Teo Soon
    Abu Bakar, Ab Halim
    Mokhlis, Hazlie
    Chen, George
    Lewin, Paul L.
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 750 - 755
  • [7] Partial discharge detection method for power equipment based on UHF method
    Liu S.
    Zhang J.
    International Journal of Energy Technology and Policy, 2024, 19 (1-2) : 120 - 134
  • [8] Detection of partial discharge in the high voltage apparatus
    Zheng, DC
    Zhang, CX
    Chen, CT
    Yu, CS
    Yang, JX
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 323 - 326
  • [9] Classification of Partial Discharge Detection Technique in High Voltage Power Component: A Review
    Rohani, M. N. K. H.
    Zaidi, A. A. H.
    Sakanovic, A.
    Wooi, C. L.
    Rosmi, A. S.
    Isa, M.
    Ismail, B.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (04): : 237 - 243
  • [10] A Proposed Intensity Modulated Optical Fiber Based Sensor for Partial Discharge Detection in High Voltage Power Transformer
    Adhikari, Krishanlal
    Koley, Chiranjib
    Roy, Nirmal Kumar
    2022 IEEE 6TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS, CATCON, 2022, : 379 - 383