Fast Frequency Regulation Utilizing Non-Aggregate Thermostatically Controlled Loads Based on Edge Intelligent Terminals

被引:6
作者
Qi, Taoyi [1 ,2 ]
Ye, Chengjin [1 ]
Hui, Hongxun [2 ]
Zhao, Yuming [3 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
[2] Univ Macau, State Key Lab Internet Things Smart City, Macau, Peoples R China
[3] Shenzhen Power Supply Bur Co Ltd, Elect Power Res Inst, Shenzhen 518001, Peoples R China
关键词
Fast frequency regulation; thermostatically controlled load; intelligent terminal; cloud-edge collaboration; AIR-CONDITIONERS; DEMAND; SERVICES;
D O I
10.1109/TSG.2023.3346467
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Thermostatically controlled loads (TCLs) have promising regulation potential and are regarded as valuable flexible resources. Due to the relatively lower operating power, TCLs are always aggregated to participate in various regulation programs. However, the intrinsic response delays of aggregation always result in relatively slower speed and limit further implementation in the fast frequency regulation (FFR) service, which is urgently needed by renewable power systems without sufficient inertias. Therefore, a non-aggregate method based on edge intelligent terminal (EIT) is proposed to utilize TCLs to provide FFR without unacceptable rebound effects. Firstly, the FFR infrastructure, consisting of the distributed frequency response and centralized recovery optimization, is developed based on functions of the EIT, such as local measurement, edge computation, and flexible control. Then, the equivalent mirror recovery strategy is proposed to mitigate power fluctuations and reduce occupations of other regulation resources. On this basis, the optimal recovery problem of TCLs is formulated to achieve flexible power control without violations of FFR requirements. To overcome the curse of dimensionality, the dynamic clustering method is proposed to divide non-aggregate TCLs into tens of groups, thereby the optimization problem is solved by EITs separately and the solution speed is independent of system scales. Finally, the proposed FFR is validated based on several simulation cases, and results show that TCLs significantly contribute to enhancing frequency resilience for low-inertia power systems.
引用
收藏
页码:3571 / 3584
页数:14
相关论文
共 34 条
[1]   Economic and Environmental Benefits of Dynamic Demand in Providing Frequency Regulation [J].
Aunedi, Marko ;
Kountouriotis, P. -Aristidis ;
Calderon, J. E. Ortega ;
Angeli, David ;
Strbac, Goran .
IEEE TRANSACTIONS ON SMART GRID, 2013, 4 (04) :2036-2048
[2]   Optimal Portfolio of Distinct Frequency Response Services in Low-Inertia Systems [J].
Badesa, Luis ;
Teng, Fei ;
Strbac, Goran .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (06) :4459-4469
[3]   Simultaneous Scheduling of Multiple Frequency Services in Stochastic Unit Commitment [J].
Badesa, Luis ;
Teng, Fei ;
Strbac, Goran .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2019, 34 (05) :3858-3868
[4]   Planning multiple energy systems for low-carbon districts with high penetration of renewable energy: An empirical study in China [J].
Cheng, Yaohua ;
Zhang, Ning ;
Kirschen, Daniel S. ;
Huang, Wujing ;
Kang, Chongqing .
APPLIED ENERGY, 2020, 261
[5]   Evaluation and Sequential Dispatch of Operating Reserve Provided by Air Conditioners Considering Lead-Lag Rebound Effect [J].
Cui, Wenqi ;
Ding, Yi ;
Hui, Hongxun ;
Lin, Zhenzhi ;
Du, Pengwei ;
Song, Yonghua ;
Shao, Changzheng .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (06) :6935-6950
[6]   Real-Time Primary Frequency Regulation Using Load Power Control by Smart Transformers [J].
De Carne, Giovanni ;
Buticchi, Giampaolo ;
Liserre, Marco ;
Vournas, Constantine .
IEEE TRANSACTIONS ON SMART GRID, 2019, 10 (05) :5630-5639
[7]   Designing a novel demand side regulation algorithm to participate in frequency control using iterated mappings [J].
Dehghanpour, Kaveh ;
Afsharnia, Saeed .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (10) :1687-1699
[8]   Sparse and Resilient Hierarchical Direct Load Control for Primary Frequency Response Improvement and Inter-Area Oscillations Damping [J].
Delavari, Atieh ;
Kamwa, Innocent .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (05) :5309-5318
[9]   Market Designs for the Primary Frequency Response Ancillary Service-Part I: Motivation and Design [J].
Ela, Erik ;
Gevorgian, Vahan ;
Tuohy, Aidan ;
Kirby, Brendan ;
Milligan, Michael ;
O'Malley, Mark .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (01) :421-431
[10]  
Electr. Reliab. Council Texas Austin TX USA, 2018, Overview of Renewables in the ERCOT System