Numerical study on cooling characteristics of turbine blade based on laminated cooling configuration with clapboards

被引:2
|
作者
Chen, Zhimin [1 ]
Chen, Xuejiao [3 ]
Yang, Xufei [2 ]
Yu, Bo [2 ]
Wang, Bohong [4 ]
Zhu, Jianqin [5 ]
Chen, Yujie [2 ]
Cai, Weihua [1 ]
机构
[1] Northeast Elect Power Univ, Sch Energy & Power Engn, Lab Thermofluid Sci & Nucl Engn, Jilin 132012, Peoples R China
[2] Beijing Inst Petrochem Technol, Sch Mech Engn, Beijing Key Lab Pipeline Crit Technol & Equipment, Beijing 102617, Peoples R China
[3] Beijing Inst Aerosp Testing Technol, Beijing 100074, Peoples R China
[4] Zhejiang Ocean Univ, Natl & Local Joint Engn Res Ctr Harbor Oil & Gas S, Zhejiang Prov Key Lab Petrochem Pollut Control, Zhoushan 316022, Peoples R China
[5] Beihang Univ, Sch Energy & Power Engn, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
Laminated cooling configuration with clapboards; Internal heat transfer area; Overall cooling effectiveness; Performance evaluation criterion; FILM; PERFORMANCE; ENHANCEMENT; ANGLE; FLOW;
D O I
10.1016/j.energy.2024.131372
中图分类号
O414.1 [热力学];
学科分类号
摘要
The double-wall configuration, characterized by its notable overall cooling effectiveness, serves as a pivotal reference configuration in the design of next-generation turbine blades. In this study, a laminated cooling configuration with clapboards is developed, based on insights derived from both double-wall cooling configuration and laminated cooling configuration. Through a comparative analysis, with the double-wall cooling configuration and laminated cooling configuration as benchmarks, the newly constructed configuration is capable of enhancing overall cooling effectiveness while maintaining control over total pressure loss in the study. Specifically, in the context of external film cooling with an adiabatic condition, the laminated cooling configuration with clapboards attains the highest value at low blowing ratios, while the laminated cooling configuration excels in average adiabatic film cooling effectiveness at high blowing ratios. Importantly, the inclusion of clapboards significantly improves the internal heat transfer area, resulting in a greater internal total heat exchange in the laminated cooling configuration with clapboards. Consequently, this proposed configuration achieves the highest overall cooling effectiveness, achieving increases of 9.02% - 14.08 % and 2.77 % - 3.54 % relative to the double-wall cooling configuration and laminated cooling configuration, respectively. A comprehensive performance evaluation criterion is applied to assess cooling effectiveness and pressure loss. The results indicate that the laminated cooling configuration with clapboards enhances heat transfer effectiveness while effectively controlling pressure drop, with an evaluation value of over 1.0. Furthermore, the overall cooling effectiveness of the three cooling configurations is compared at two Reynolds numbers. It is found that the proposed configuration exhibits the best cooling performance, especially at the high Reynolds number.
引用
收藏
页数:17
相关论文
共 50 条
  • [11] Experimental study of cooling air effect on overall cooling of laminated configuration at a turbine vane end-wall
    Pu, Jian
    Zhang, Tiao
    Wang, Jian-hua
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 32
  • [12] Numerical evaluation of the blade cooling for the supercritical steam turbine
    Wroblewski, Wlodzimierz
    APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) : 953 - 962
  • [13] Numerical Computation and Optimization of Turbine Blade Film Cooling
    Elsayed, Ahmed M.
    Owis, Farouk M.
    Rahman, M. Madbouli Abdel
    ADVANCES IN MECHANICAL ENGINEERING, 2014,
  • [14] Study on Turbine Blade Fractures of Some Cooling Turbine
    Zhao Yunfeng
    2016 IEEE/CSAA INTERNATIONAL CONFERENCE ON AIRCRAFT UTILITY SYSTEMS (AUS), 2016, : 1070 - 1074
  • [15] Study on Aerodynamic and Cooling Performance of Turbine Blade Squealer Tip with Film Cooling Pulsation Characteristics Considered
    Xu C.
    Li Z.
    Li J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2022, 56 (05): : 127 - 140
  • [16] Numerical Study of Swirl Cooling in a Turbine Blade Leading-Edge Model
    Liu, Zhao
    Li, Jun
    Feng, Zhenping
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2015, 29 (01) : 166 - 178
  • [17] FILM-COOLING CHARACTERISTICS OF UPSTREAM RAMP ENHANCED TURBINE BLADE SURFACE COOLING
    Halder, Paresh
    Samad, Abdus
    Kim, Jun-Hee
    Kim, Kwang-Yong
    HEAT TRANSFER RESEARCH, 2017, 48 (11) : 969 - 984
  • [18] Numerical simulation of film cooling in leading edge of turbine blade
    College of Power and Energy Engineering, Harbin University of Engineering, Harbin 150001, China
    不详
    不详
    Hangkong Dongli Xuebao, 2009, 3 (519-525): : 519 - 525
  • [19] NUMERICAL SIMULATION OF IMPINGING COOLING ON THE LEADING EDGE OF A TURBINE BLADE
    Cheng, Keyong
    Huai, Xiulan
    Cai, Jun
    Guo, Zhixiong
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2011, VOL 10, PTS A AND B, 2012, : 1077 - 1085
  • [20] NUMERICAL SIMULATION OF TURBINE BLADE COOLING VIA JET IMPINGEMENT
    Al Ali, Abdulla R.
    Janajreh, Isam
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 3220 - 3229