The fabrication and characterization of direct conversion flat panel X-ray imager with TlBr film

被引:2
作者
Hamdan, Moh [1 ]
Shimazoe, Kenji [1 ]
Takahashi, Hiroyuki [1 ]
Nogami, Mitsuhiro [2 ]
Hitomi, Keitaro [2 ]
Asakura, Shinya [3 ]
Tsunashima, Takanori [3 ]
Nakamura, Takashi [3 ]
机构
[1] Univ Tokyo, Grad Sch Engn, Dept Nucl Engn & Management, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1138656, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Quantum Sci & Energy Engn, Sendai 9808579, Japan
[3] Japan Display Inc, R&D Div, Device Dev Dept, Mobara Plant, 3300 Hayano, Mobara, Chiba 2978622, Japan
关键词
TlBr film; LTPS TFT; FPD; X-ray imaging; DETECTOR; FEASIBILITY; PERFORMANCE;
D O I
10.1016/j.nima.2024.169372
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The novel direct conversion flat panel detectors (FPDs) utilizing thallium bromide (TlBr) films are developed and characterized in this study. Thin TlBr films, deposited using an evaporation technique, achieved thicknesses of 10 mu m and 50 mu m. A pixel sensor array, with a pixel size of 235 x 235 mu m(2) and a sensitive area of 29.61 x 39.48 mm(2), was developed using low-temperature polysilicon thin-film transistor (LTPS TFT) technology as the initial study to explore performance characteristics of developed imaging system. The TlBr film was characterized based on the current-voltage (I-V) profile, showing a resistivity of 2.78 x 1010 Omega.cm. The LTPS TFT showed a leakage current of about 10-13 A, while the noise of TlBr FPD system was around 104 e(-) rms, primarily limited by the readout system. The detector system was characterized using radiation from an X-ray tube with a voltage in the range of 30 kV-100 kV and a current of 2 mA, involving an X-ray test chart as the object with the processing time of 18.15-18.30 ms per frame. Based on the contrast and contrast-to-noise ratio (CNR) values, the 10 mu m and 50 mu m TlBr FPD clearly captured the image in operation between 30 kV and 100 kV. The 50 mu m TlBr FPD demonstrated improved sensitivity, showing pixel values with 10 times higher intensity and enhanced line pair detail at 30 kV X-ray operation. The 10 mu m TlBr achieved spatial resolution of 267 mu m full width at half maximum (FWHM), while the 50 mu m TlBr achieved 250 mu m FWHM. In the X-ray imaging demonstration, the shape and structure of anchovy was clearly distinguished. The TlBr film FPD presents promising potential for a room temperature X-ray imager.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] X-ray imaging with PbI2-based a-Si:H flat panel detectors
    Shah, KS
    Street, RA
    Dmitriyev, Y
    Bennett, P
    Cirignano, L
    Klugerman, M
    Squillante, MR
    Entine, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) : 140 - 147
  • [32] Experimental evaluation of a novel CdZnTe flat-panel X-ray detector for digital radiography and fluoroscopy
    Tokuda, S
    Adachi, S
    Sato, T
    Yoshimuta, T
    Nagata, H
    Uehara, K
    Izumi, Y
    Teranuma, O
    Yamada, S
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 140 - 147
  • [33] A 128-Channel CMOS Charge Readout ASIC for Flat-Panel X-Ray Detectors
    Adachi, Susumu
    Nishimura, Akihiro
    Yoshimlita, Toshinori
    Tanabe, Koichi
    Okamura, Shoichi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (06) : 3673 - 3683
  • [34] Fabrication of Large Area X-ray Diffraction Grating for X-ray Phase Imaging
    Noda, Daiji
    Tokuoka, Atsushi
    Katori, Megumi
    Minamiyama, Yasuto
    Yamashita, Kenji
    Nishida, Satoshi
    Hattori, Tadashi
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 51 - 56
  • [35] Direct-Conversion X-Ray Detector Using Lateral Amorphous Selenium Structure
    Chen, Feng
    Wang, Kai
    Fang, Yuan
    Allec, Nicholas
    Belev, George
    Kasap, Safa
    Karim, Karim S.
    IEEE SENSORS JOURNAL, 2011, 11 (02) : 505 - 509
  • [36] X-ray photoemission analysis of chemically modified TlBr surfaces for improved radiation detectors
    Nelson, A. J.
    Voss, L. F.
    Beck, P. R.
    Graff, R. T.
    Conway, A. M.
    Nikolic, R. J.
    Payne, S. A.
    Lee, J. -S.
    Kim, H.
    Cirignano, L.
    Shah, K.
    JOURNAL OF APPLIED PHYSICS, 2013, 113 (14)
  • [37] Fabrication and characterization of a phosphor based photon conversion film
    Shen, Xia
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2017, 28 (24) : 18585 - 18591
  • [38] X-ray film as a two-dimensional detector for X-ray diffraction analysis
    Blanton, TN
    POWDER DIFFRACTION, 2003, 18 (02) : 91 - 98
  • [39] Fabrication of Lightweight Silicon X-ray Mirrors
    Riveros, Raul E.
    Allgood, Kim D.
    Biskach, Michael P.
    DeVita, Tabatha A.
    Hlinka, Michal
    Kearney, John D.
    Numata, Ai
    Zhang, William W.
    SPACE TELESCOPES AND INSTRUMENTATION 2022: ULTRAVIOLET TO GAMMA RAY, 2022, 12181
  • [40] DQE(f) of an amorphous silicon flat panel x-ray detector: Detector parameter influences and measurement methodology
    Granfors, PR
    Aufrichtig, R
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 2 - 13