Comparison of R2*and FerriScan liver iron concentration (LIC) quantification in the clinical classification of Iron overload states

被引:0
|
作者
Sussman, Marshall S. [1 ,2 ]
Kannengiesser, Stephan A. R. [4 ]
Prasla, Shopnil [1 ,2 ]
Ward, Richard [3 ]
Jhaveri, Kartik S. [1 ,2 ]
机构
[1] Univ Hlth Network, Mt Sinai Hosp, Joint Dept Med Imaging, Toronto, ON, Canada
[2] Univ Toronto, Womens Coll Hosp, Toronto, ON, Canada
[3] Univ Toronto, Univ Hlth Network, Div Med Oncol & Hematol, Toronto, ON, Canada
[4] Siemens Healthcare, MR Applicat Predev, Erlangen, Germany
关键词
Liver; Iron overload; Magnetic resonance imaging; Magnetic resonance imaging methods; Magnetic resonance imaging statistics and numerical data; HEPATIC IRON; CHELATING THERAPY; MRI; R2;
D O I
10.1016/j.mri.2024.110216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study assessed the clinical classification performance of an R2*-based MRI technique for LIC quantification relative to FerriScan, with intra-patient FerriScan LIC uncertainty taken into account. The variabilities of R2* and FerriScan LIC were also assessed. Materials and methods: This was an ethics approved retrospective study, performed on patients undergoing chelation treatment for iron overload. 126 patients (69 women, 57 men), with an age of 42 +/- 16 years (range 19-86 years) were included. FerriScan and R2* MRI at 1.5 T were performed as part of a routine liver iron assessment protocol. For R2* MRI, a commercially available pulse sequence and reconstruction implementation was used, together with a previously derived calibration curve to convert R2* to LIC. Clinical classifications arising from R2*-derived LIC estimates were compared to those based on FerriScan. The accuracy and precision of the R2* technique was calculated. The variabilities of FerriScan- and R2*-derived estimates of LIC were compared with a Wilcoxon Signed Rank test. Significance was set at the 95% confidence level. Results: The precision of R2* ranged from 0.59 to 0.92, with an overall accuracy of 72%. When intra-patient FerriScan LIC uncertainty was considered, precision and accuracy increased to >94% and 97% respectively. The R2*-LIC variability (=17%) was significantly lower than the FerriScan-LIC variability (34%) at the 95% confidence level (p p < 10(-3)). Conclusion: MRI R2*-based LIC estimates provided a similar clinical classification as FerriScan. The intra-patient uncertainty of R2*-based LIC estimates was significantly lower than FerriScan.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Measurement of liver iron overload: Noninvasive calibration of MRI-R2*by magnetic iron detector susceptometer
    Gianesin, B.
    Zefiro, D.
    Musso, M.
    Rosa, A.
    Bruzzone, C.
    Balocco, M.
    Carrara, P.
    Bacigalupo, L.
    Banderali, S.
    Rollandi, G. A.
    Gambaro, M.
    Marinelli, M.
    Forni, G. L.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (06) : 1782 - 1786
  • [42] Evaluation of hepatic iron concentration heterogeneities using the MRI R2*mapping method
    Maze, Jean
    Vesselle, Guillaume
    Herpe, Guillaume
    Boucebci, Samy
    Silvain, Christine
    Ingrand, Pierre
    Tasu, Jean-Pierre
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 116 : 47 - 54
  • [43] Correlation of R2 with total iron concentration in the brains of rhesus monkeys
    Hardy, PA
    Gash, D
    Yokel, R
    Andersen, A
    Ai, Y
    Zhang, ZM
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) : 118 - 127
  • [44] Inter-method reproducibility of biexponential R2 MR relaxometry for estimation of liver iron concentration
    Pirasteh, Ali
    Yuan, Qing
    Hernando, Diego
    Reeder, Scott B.
    Pedrosa, Ivan
    Yokoo, Takeshi
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2691 - 2701
  • [45] Practical Application of Multivendor MRI-Based R2 Mapping for Liver Iron Quantification at 1.5 T and 3.0 T
    Simchick, Gregory
    Zhao, Ruiyang
    Yuan, Qing
    Ghasabeh, Mounes Aliyari
    Ruschke, Stefan
    Karampinos, Dimitrios C.
    Harris, David T.
    do Vale Souza, Raphael
    Mattison, Ryan J.
    Jeng, Michael R.
    Pedrosa, Ivan
    Kamel, Ihab R.
    Vasanawala, Shreyas
    Yokoo, Takeshi
    Reeder, Scott B.
    Hernando, Diego
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2025, 61 (01) : 150 - 165
  • [46] MRI-based R2* mapping in patients with suspected or known iron overload
    Emre Aslan
    Jack W. Luo
    An Lesage
    Philippe Paquin
    Milena Cerny
    Anne Shu-Lei Chin
    Damien Olivié
    Guillaume Gilbert
    Denis Soulières
    An Tang
    Abdominal Radiology, 2021, 46 : 2505 - 2515
  • [47] Monitoring Iron Overload: Relationship between R2(star) Relaxometry of the Liver and Serum Ferritin under Different Therapies
    Plaikner, Michaela
    Kremser, Christian
    Zoller, Heinz
    Jaschke, Werner
    Henninger, Benjamin
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2018, 8
  • [48] Liver iron overload assessment by MRI R2*relaxometry in highly transfused pediatric patients: An agreement and reproducibility study
    Verlhac, S.
    Morel, M.
    Bernaudin, F.
    Bechet, S.
    Jung, C.
    Vasile, M.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (03) : 259 - 264
  • [49] Reproducibility of liver iron concentration estimates in MRI through R2*measurement determined by least-squares curve fitting
    Headley, Andrew M.
    Grice, Jared V.
    Pickens, David R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (12): : 295 - 303
  • [50] Reproducibility of liver iron concentration measured by R2*method based on 1.5-T MRI: a meta-analysis
    Cao, Sue
    Zhang, Jie
    Dong, Chenyu
    Que, Yutao
    Gao, Xin
    Guo, Ruomi
    EUROPEAN RADIOLOGY, 2025,