Comparison of R2*and FerriScan liver iron concentration (LIC) quantification in the clinical classification of Iron overload states

被引:0
|
作者
Sussman, Marshall S. [1 ,2 ]
Kannengiesser, Stephan A. R. [4 ]
Prasla, Shopnil [1 ,2 ]
Ward, Richard [3 ]
Jhaveri, Kartik S. [1 ,2 ]
机构
[1] Univ Hlth Network, Mt Sinai Hosp, Joint Dept Med Imaging, Toronto, ON, Canada
[2] Univ Toronto, Womens Coll Hosp, Toronto, ON, Canada
[3] Univ Toronto, Univ Hlth Network, Div Med Oncol & Hematol, Toronto, ON, Canada
[4] Siemens Healthcare, MR Applicat Predev, Erlangen, Germany
关键词
Liver; Iron overload; Magnetic resonance imaging; Magnetic resonance imaging methods; Magnetic resonance imaging statistics and numerical data; HEPATIC IRON; CHELATING THERAPY; MRI; R2;
D O I
10.1016/j.mri.2024.110216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study assessed the clinical classification performance of an R2*-based MRI technique for LIC quantification relative to FerriScan, with intra-patient FerriScan LIC uncertainty taken into account. The variabilities of R2* and FerriScan LIC were also assessed. Materials and methods: This was an ethics approved retrospective study, performed on patients undergoing chelation treatment for iron overload. 126 patients (69 women, 57 men), with an age of 42 +/- 16 years (range 19-86 years) were included. FerriScan and R2* MRI at 1.5 T were performed as part of a routine liver iron assessment protocol. For R2* MRI, a commercially available pulse sequence and reconstruction implementation was used, together with a previously derived calibration curve to convert R2* to LIC. Clinical classifications arising from R2*-derived LIC estimates were compared to those based on FerriScan. The accuracy and precision of the R2* technique was calculated. The variabilities of FerriScan- and R2*-derived estimates of LIC were compared with a Wilcoxon Signed Rank test. Significance was set at the 95% confidence level. Results: The precision of R2* ranged from 0.59 to 0.92, with an overall accuracy of 72%. When intra-patient FerriScan LIC uncertainty was considered, precision and accuracy increased to >94% and 97% respectively. The R2*-LIC variability (=17%) was significantly lower than the FerriScan-LIC variability (34%) at the 95% confidence level (p p < 10(-3)). Conclusion: MRI R2*-based LIC estimates provided a similar clinical classification as FerriScan. The intra-patient uncertainty of R2*-based LIC estimates was significantly lower than FerriScan.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Evaluation of liver iron overload with R2*relaxometry with versus without fat suppression: both are clinically accurate but there are differences
    Plaikner, M.
    Kremser, C.
    Zoller, H.
    Jaschke, W.
    Steurer, M.
    Viveiros, A.
    Henninger, B.
    EUROPEAN RADIOLOGY, 2020, 30 (11) : 5826 - 5833
  • [22] R2*Relaxometry for the Quantification of Hepatic Iron Overload: Biopsy-Based Calibration and Comparison with the Literature
    Henninger, B.
    Zoller, H.
    Rauch, S.
    Finkenstedt, A.
    Schocke, M.
    Jaschke, W.
    Kremser, C.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (06): : 472 - 479
  • [23] The uses and differences of R2 and R2* in the determination of iron overload in iron loaded thalassemia patients
    Gotsis, Efstathios D.
    HEMOGLOBIN, 2008, 32 (1-2) : 75 - 83
  • [24] Comparison of liver MRI R2(FerriScan®) VS liver MRI T2*as a measure of body iron load in a cohort of beta thalassaemia major patients
    Padeniya, Padmapani
    Siriwardana, Shirom
    Ediriweera, Dileepa
    Samarasinghe, Nayana
    Silva, Sasanka
    Silva, Ishari
    Ahamed, Nizri
    Niriella, Madunil
    Premawardhena, Anuja
    ORPHANET JOURNAL OF RARE DISEASES, 2020, 15 (01)
  • [25] Comparison of liver MRI R2(FerriScan®) VS liver MRI T2* as a measure of body iron load in a cohort of beta thalassaemia major patients
    Padmapani Padeniya
    Shirom Siriwardana
    Dileepa Ediriweera
    Nayana Samarasinghe
    Sasanka Silva
    Ishari Silva
    Nizri Ahamed
    Madunil Niriella
    Anuja Premawardhena
    Orphanet Journal of Rare Diseases, 15
  • [26] Measurement of the liver iron concentration in transfusional iron overload by MRI R2*and by high-transition-temperature superconducting magnetic susceptometry
    Sheth, Sujit
    Allen, Christopher J.
    Farrell, David E.
    Tripp, John H.
    Jafari, Ramin
    Wang, Yi
    Brittenham, Gary M.
    CLINICAL IMAGING, 2019, 55 : 65 - 70
  • [27] The Effect of Reducing Repetition Time TR on the Measurement of Liver R2 for the Purpose of Measuring Liver Iron Concentration
    Pavitt, Helen L.
    Aydinok, Yesim
    El-Beshlawy, Amal
    Bayraktaroglu, Selen
    Ibrahim, Ahmed S.
    Hamdy, Mona M.
    Pang, Wenjie
    Sharples, Christopher
    St Pierre, Timothy G.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (05) : 1346 - 1351
  • [28] Estimation of pancreatic R2*for iron overload assessment in the presence of fat: a comparison of different approaches
    Santarelli, Maria Filomena
    Meloni, Antonella
    De Marchi, Daniele
    Pistoia, Laura
    Quarta, Antonella
    Spasiano, Anna
    Landini, Luigi
    Pepe, Alessia
    Positano, Vincenzo
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2018, 31 (06) : 757 - 769
  • [29] Whole liver phase-based R2 mapping in liver iron overload within a breath-hold
    Tamada, Daiki
    Navaratna, Ruvini
    Weaver, Jayse Merle
    Hernando, Diego
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2025,
  • [30] Real-World Experience Measurement of Liver Iron Concentration by R2 vs. R2 Star MRI in Hemoglobinopathies
    Abou Zahr, Riad
    Burkhardt, Barbara E. U.
    Ehsan, Lubaina
    Potersnak, Amanda
    Greil, Gerald
    Dillenbeck, Jeanne
    Rogers, Zora
    Hussain, Tarique
    DIAGNOSTICS, 2020, 10 (10)