Comparison of R2*and FerriScan liver iron concentration (LIC) quantification in the clinical classification of Iron overload states

被引:0
|
作者
Sussman, Marshall S. [1 ,2 ]
Kannengiesser, Stephan A. R. [4 ]
Prasla, Shopnil [1 ,2 ]
Ward, Richard [3 ]
Jhaveri, Kartik S. [1 ,2 ]
机构
[1] Univ Hlth Network, Mt Sinai Hosp, Joint Dept Med Imaging, Toronto, ON, Canada
[2] Univ Toronto, Womens Coll Hosp, Toronto, ON, Canada
[3] Univ Toronto, Univ Hlth Network, Div Med Oncol & Hematol, Toronto, ON, Canada
[4] Siemens Healthcare, MR Applicat Predev, Erlangen, Germany
关键词
Liver; Iron overload; Magnetic resonance imaging; Magnetic resonance imaging methods; Magnetic resonance imaging statistics and numerical data; HEPATIC IRON; CHELATING THERAPY; MRI; R2;
D O I
10.1016/j.mri.2024.110216
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study assessed the clinical classification performance of an R2*-based MRI technique for LIC quantification relative to FerriScan, with intra-patient FerriScan LIC uncertainty taken into account. The variabilities of R2* and FerriScan LIC were also assessed. Materials and methods: This was an ethics approved retrospective study, performed on patients undergoing chelation treatment for iron overload. 126 patients (69 women, 57 men), with an age of 42 +/- 16 years (range 19-86 years) were included. FerriScan and R2* MRI at 1.5 T were performed as part of a routine liver iron assessment protocol. For R2* MRI, a commercially available pulse sequence and reconstruction implementation was used, together with a previously derived calibration curve to convert R2* to LIC. Clinical classifications arising from R2*-derived LIC estimates were compared to those based on FerriScan. The accuracy and precision of the R2* technique was calculated. The variabilities of FerriScan- and R2*-derived estimates of LIC were compared with a Wilcoxon Signed Rank test. Significance was set at the 95% confidence level. Results: The precision of R2* ranged from 0.59 to 0.92, with an overall accuracy of 72%. When intra-patient FerriScan LIC uncertainty was considered, precision and accuracy increased to >94% and 97% respectively. The R2*-LIC variability (=17%) was significantly lower than the FerriScan-LIC variability (34%) at the 95% confidence level (p p < 10(-3)). Conclusion: MRI R2*-based LIC estimates provided a similar clinical classification as FerriScan. The intra-patient uncertainty of R2*-based LIC estimates was significantly lower than FerriScan.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Comparison of clinical MRI liver iron content measurements using signal intensity ratios, R2 and R2*
    Jurgen H. Runge
    Erik M. Akkerman
    Marian A. Troelstra
    Aart J. Nederveen
    Ulrich Beuers
    Jaap Stoker
    Abdominal Radiology, 2016, 41 : 2123 - 2131
  • [12] Complex confounder-corrected R2* mapping for liver iron quantification with MRI
    Diego Hernando
    Rachel J. Cook
    Naila Qazi
    Colin A. Longhurst
    Carol A. Diamond
    Scott B. Reeder
    European Radiology, 2021, 31 : 264 - 275
  • [13] Complex confounder-corrected R2*mapping for liver iron quantification with MRI
    Hernando, Diego
    Cook, Rachel J.
    Qazi, Naila
    Longhurst, Colin A.
    Diamond, Carol A.
    Reeder, Scott B.
    EUROPEAN RADIOLOGY, 2021, 31 (01) : 264 - 275
  • [14] A confirmatory study of the calibration formula between liver iron concentration (LIC) and R2* values in thalassemia patients
    Fengming Xu
    Jixing Yi
    Cheng Tang
    Chaotian Luo
    Peng Peng
    Chinese Journal of Academic Radiology, 2023, 6 : 65 - 72
  • [15] Comparison of liver iron concentration calculated from R2* at 1.5 T and 3 T
    Elisabeth Pickles
    Shravan Kumar
    Michael Brady
    Alison Telford
    Michael Pavlides
    Daniel Bulte
    Abdominal Radiology, 2023, 48 : 865 - 873
  • [16] Comparison of liver iron concentration calculated from R2*at 1.5 T and 3 T
    Pickles, Elisabeth
    Kumar, Shravan
    Brady, Michael
    Telford, Alison
    Pavlides, Michael
    Bulte, Daniel
    ABDOMINAL RADIOLOGY, 2023, 48 (03) : 865 - 873
  • [17] Comparison of whole liver and small region-of-interest measurements of MRI liver R2* in children with iron overload
    M. Beth McCarville
    Claudia M. Hillenbrand
    Ralf B. Loeffler
    Matthew P. Smeltzer
    Ruitan Song
    Chin-Shang Li
    Jane S. Hankins
    Pediatric Radiology, 2010, 40 : 1360 - 1367
  • [18] A semiautomatic postprocessing of liver R2* measurement for assessment of liver iron overload
    Deng, Jie
    Rigsby, Cynthia K.
    Schoeneman, Samantha
    Boylan, Emma
    MAGNETIC RESONANCE IMAGING, 2012, 30 (06) : 799 - 806
  • [19] R2* magnetic resonance imaging of the liver in patients with iron overload
    Hankins, Jane S.
    McCarville, M. Beth
    Loeffler, Ralf B.
    Smeltzer, Matthew P.
    Onciu, Mihaela
    Hoffer, Fredric A.
    Li, Chin-Shang
    Wang, Winfred C.
    Ware, Russell E.
    Hillenbrand, Claudia M.
    BLOOD, 2009, 113 (20) : 4853 - 4855
  • [20] R2 relaxometry with MRI for the quantification of tissue iron overload in β-thalassemic patients
    Alexopoulou, E
    Stripeli, F
    Baras, P
    Seimenis, L
    Kattamis, A
    Ladis, V
    Efstathopoulos, E
    Brountzos, EN
    Kelekis, AD
    Kelekis, NL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (02) : 163 - 170