摘要
Objectives: The depth of cure using blue -light photocuring units (BL) is limited by tooth structure and qualities of the restorative material through which the activating wavelength must pass. Recent developments incorporate an infrared (IR) activated upconversion (UC) fluorescence of a lining agent filled with nanocrystals of NaYF 4 and doped with YB +3 and Tm +3 that emit both blue and violet light locally at the interface of the liner and restorative resin. The purpose of this study was to evaluate the BL and 975 nm infrared (IR) light power transmission through dental tissues and restorative materials. Methods and Materials: Power transmissions of the IR laser (975 nm) and a monowave blue -only lightcuring unit (Bluephase 16i) through dental tissues (enamel, dentin, and enamel/dentin junction, or DEJ), eight (8) various dental resin composites, and eight (8) dental ceramics, each at four thicknesses (1, 2, 3 and 4 mm) were evaluated (n=5) using a thermopile sensor (PM10, Coherent Inc) connected to a laser power meter (Fieldmate, Coherent Inc). Power transmission values of each light source and restorative material were subjected to analysis of variance and Tukey test at a pre-set alpha of 0.05. Results: A linear correlation (r=0.9884) between the supplied current and emitted IR power of the laser diode was found, showing no statistical power reduction with increased distances (collimated beam). For tooth tissues, the highest power transmissions for both light sources were observed using 1.0 mm enamel while the lowest values were found for 2.0 mm dentin and an association of 2.0 mm DEJ and 1.0 mm dentin. The only group where IR demonstrated significantly higher transmission when compared to BL was 1.0 mm enamel. For all resin composites and dental ceramics, increased thickness resulted in a reduction of IR power transmission (except for EverX Posterior fiberreinforced composite and e.max HT ceramic). IR resulted in higher transmission through all resin composites, except for Tetric EvoCeram White. The highest BL transmission was observed for SDR Flow, at all thicknesses. Higher IR/BL ratios were observed for EverX Posterior, Herculite Ultra, and Lava Ultimate, while the lowest ratio was observed for Tetric EvoCeram White. Reduced translucency shades within the same material resulted in lower power ratio values, especially for BL transmission. Higher IR/BL ratios were observed for e.Max LT, VitaVM7 Base Dentin, and e.max CAD HT, while the lowest values were found for VitaVM7 Enamel and Paradigm C. Conclusion: IR power transmission through enamel was higher when compared to blue light, while no difference was observed for dentin. The power transmission of IR was higher than BL for resin composites, except for a high value and low chroma shade. Fiber -reinforced resin composite demonstrated the highest IR/BL power transmission ratio. A greater IR/BL ratio was observed for lower translucency ceramics when compared to high translucency.
引用
收藏
页码:300 / 310
页数:11
相关论文
共 50 条
  • [1] Light scattering in hard dental tissues and restorative materials
    Grisimov, VN
    Smirnov, AV
    Stafeev, SK
    IZVESTIYA AKADEMII NAUK SERIYA FIZICHESKAYA, 1997, 61 (08): : 1590 - 1595
  • [2] Laser equipment for investigation of light distribution in dental tissues and restorative materials
    Grisimov, VN
    Smirnov, AV
    Stafeev, SC
    LASER APPLICATIONS ENGINEERING (LAE-96), 1997, 3091 : 152 - 156
  • [3] A Comparative Study of Light Transmission by Various Dental Restorative Materials and the Tooth Structure
    Ray, Anwetakshmi
    Kundabala, M.
    Shetty, Neeta
    OPERATIVE DENTISTRY, 2020, 45 (04) : 453 - 453
  • [4] Wear behavior of hard dental tissues and restorative materials
    Ctvrtlik, Radim
    Tomastik, Jan
    EXPERIMENTAL STRESS ANALYSIS 51, 2014, 486 : 72 - 77
  • [5] COMPARISON OF RHEOLOGICAL PROPERTIES OF 4 DENTAL RESTORATIVE MATERIALS
    TORGALKAR, AM
    JOURNAL OF DENTAL RESEARCH, 1973, 52 (03) : 476 - 482
  • [6] The effect of curing with plasma light on the shrinkage of dental restorative materials
    Deb, S
    Mallett, R
    Millar, B
    JOURNAL OF ORAL REHABILITATION, 2003, 30 (07) : 723 - 728
  • [7] Ion migration from fluoride-releasing dental restorative materials into dental hard tissues
    Gjorgievska, Elizabeta
    Nicholson, John W.
    Grcev, Aleksandar T.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2012, 23 (07) : 1811 - 1821
  • [8] Ion migration from fluoride-releasing dental restorative materials into dental hard tissues
    Elizabeta Gjorgievska
    John W. Nicholson
    Aleksandar T. Grcev
    Journal of Materials Science: Materials in Medicine, 2012, 23 : 1811 - 1821
  • [9] Light transmission through all-ceramic dental materials: A pilot study
    Rasetto, FH
    Driscoll, CF
    Prestipino, V
    Masri, R
    von Fraunhofer, JA
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (05): : 441 - 446
  • [10] A Deep Morphological Characterization and Comparison of Different Dental Restorative Materials
    Condo, R.
    Cerroni, L.
    Pasquantonio, G.
    Mancini, M.
    Pecora, A.
    Convertino, A.
    Mussi, V.
    Rinaldi, A.
    Maiolo, L.
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017