Bare-Metal Stent in Dysfunctional Hemodialysis Access: An Assessment of Circuit Patency according to Access Type and Stent Location

被引:1
作者
Lee, Kyungmin [1 ]
Won, Je Hwan [1 ]
Kwon, Yohan [1 ]
Lee, Su Hyung [2 ]
Bang, Jun Bae [2 ]
Kim, Jinoo [1 ]
机构
[1] Ajou Univ, Sch Med, Ajou Univ Hosp, Dept Radiol, 164 World cup Ro, Suwon 16499, South Korea
[2] Ajou Univ, Sch Med, Ajou Univ Hosp, Dept Surg, Suwon, South Korea
来源
JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY | 2023年 / 84卷 / 01期
关键词
Stent; Angioplasty; Arteriovenous Fistula; Vascular Patency; Renal Dialysis; PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY; CEPHALIC ARCH STENOSIS; BALLOON ANGIOPLASTY; ARTERIOVENOUS-FISTULAS; TECHNICAL SUCCESS; GRAFT; PLACEMENT; SALVAGE;
D O I
10.3348/jksr.2022.0069
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the circuit patency after nitinol bare-metal stent (BMS) placement according to the type of access and location of the stent in dysfunctional hemodialysis access. Materials and Methods Between January 2017 and December 2019, 159 patients (mean age, 64.1 +/- 13.2 years) underwent nitinol BMS placement for dysfunctional access. The location of stents was as follows: 18 brachiocephalic vein, 51 cephalic arch, 40 upper arm vein, 10 juxta-anastomotic vein, 7 arteriovenous (AV) anastomosis, and 33 graft-vein (GV) anastomosis. Circuit patency was evaluated by the Kaplan-Meier method, and cox regression model. Results A total of 159 stents were successfully deployed in 103 AV fistula (AVF) and 56 AV graft (AVG). AVG showed lower primary and secondary patency at 12-months compared with AVF (primary patency; 25.0% vs. 44.7%; p = 0.005, secondary patency; 76.8% vs. 92.2%; p = 0.014). Cox regression model demonstrated poorer primary patency at 12 months after stenting in the cephalic arch and GV anastomosis compared with the other sites. Conclusion AVF showed better primary and secondary circuit patency at 12 months following the placement of BMS compared with AVG. Stents in the cephalic arch and GV anastomosis were associated with poorer primary patency at 12 months compared to those in other locations.
引用
收藏
页码:197 / 211
页数:15
相关论文
共 27 条
[1]   Percutaneous transluminal balloon angioplasty in stenosis of native hemodialysis arteriovenous fistulas: technical success and analysis of factors affecting postprocedural fistula patency [J].
Aktas, Ayse ;
Bozkurt, Alper ;
Aktas, Bulent ;
Kirbas, Ismail .
DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2015, 21 (02) :160-166
[2]   A Patient with Recurrent Arteriovenous Graft Thrombosis [J].
Allon, Michael .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2015, 10 (12) :2255-2262
[3]   GIANTURCO SELF-EXPANDING STENT IN THE TREATMENT OF STENOSIS IN DIALYSIS ACCESS GRAFTS [J].
BEATHARD, GA .
KIDNEY INTERNATIONAL, 1993, 43 (04) :872-877
[4]   A Review of Percutaneous Transluminal Angioplasty in Hemodialysis Fistula [J].
Bountouris, Ioannis ;
Kritikou, Georgia ;
Degermetzoglou, Nikolaos ;
Avgerinos, Konstantinos Ioannis .
INTERNATIONAL JOURNAL OF VASCULAR MEDICINE, 2018, 2018
[5]   Stent placement versus angioplasty improves patency of arteriovenous grafts and blood flow of arteriovenous fistulae [J].
Chan, Micah R. ;
Bedi, Surmeet ;
Sanchez, Robert J. ;
Young, Henry N. ;
Becker, Yolanda T. ;
Kellerman, Paul S. ;
Yevzlin, Alexander S. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2008, 3 (03) :699-705
[6]   Outcome and prognostic factors of restenosis after percutaneous treatment of native hemodialysis fistulas [J].
Clark, TWI ;
Hirsch, DA ;
Jindal, KJ ;
Veugelers, PJ ;
LeBlanc, J .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (01) :51-59
[7]   Cephalic Arch Stenosis: Mechanisms and Management Strategies [J].
Daoui, Rachid ;
Asif, Arif .
SEMINARS IN NEPHROLOGY, 2012, 32 (06) :538-544
[8]   Promising results of stent graft placement for cephalic arch stenosis after repeated failure of angioplasty in patients on hemodialysis [J].
Feng, Pin-Chao ;
Lee, Chun-Hui ;
Hsieh, Hung-Chang ;
Ko, Po-Jen ;
Yu, Sheng-Yueh ;
Lin, Yu-Sheng .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (06)
[9]  
Gray Richard J, 2003, J Vasc Interv Radiol, V14, pS433
[10]   Stent Graft versus Balloon Angioplasty for Failing Dialysis-Access Grafts [J].
Haskal, Ziv J. ;
Trerotola, Scott ;
Dolmatch, Bart ;
Schuman, Earl ;
Altman, Sanford ;
Mietling, Samuel ;
Berman, Scott ;
McLennan, Gordon ;
Trimmer, Clayton ;
Ross, John ;
Vesely, Thomas .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (06) :494-503