Shear behavior on PBL shear connector with a relatively thin perforated steel plate in steel-UHPC composite bridge deck system

被引:2
作者
Luo, Zihao [1 ,2 ]
Zhao, Hua [1 ,2 ]
Qiao, Dongqin [1 ,2 ]
Zhang, Yufei [1 ,2 ]
An, Jiahe [1 ,2 ]
Tan, Chengjun [1 ,2 ]
Liang, Linong [3 ]
Liu, Anxing [3 ]
Shao, Xudong [1 ,2 ]
机构
[1] Hunan Univ, Coll Civil Engn, State Key Lab Bridge Engn Safety & Resilience, Changsha 410082, Peoples R China
[2] Hunan Univ, Coll Civil Engn, Key Lab Wind & Bridge Engn Hunan Prov, Changsha 410082, Peoples R China
[3] Guangdong Commun Planning & Design Inst Grp Co Ltd, Guangzhou 510507, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel-UHPC composite slab; Bridge deck system; PBL shear connector; Shear behavior; Parameter analysis; Bearing capacity;
D O I
10.1016/j.engstruct.2024.118583
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recently, a new steel-UHPC composite deck system is used for long-span bridges, which uses the perfobond rib (PBL) shear connectors with a thinner steel perforated plate. Because the steel perforated plate is thinner, its failure mode may be different from that of thicker steel perforated plate. To explore the shear behavior of PBL shear connectors in this new composite deck system, five sets of ten specimens are tested in this study. The parameters of the hole diameter, D, the traverse rebar diameter, ds, and the perforated steel plate thickness, ts are considered. The failure modes, strain development versus loading, and some mechanical indexes are discussed. The experiments show that the PBL shear connector with a thinner perforated steel plate causes a shear failure, while the thicker one results in bending or bending-shear failure. According to FE (finite element) analysis, the orthogonal analysis is conducted to investigate the effect of each parameter and their interaction on the mechanical behavior. It is found that the ultimate capacity and stiffness are the most sensitive to the diameter of the traverse rebar, ds, and the perforated steel plate thickness, ts. In addition, a theoretical formula is proposed to predict the bearing capacity of PBL shear connectors. The proposed formula considers the relationship between shear strain and the dilation angle for the first time. The results show a good agreement with the experiments. The study in this paper provides a good reference for the application and optimization of PBLs with a thinner steel perforated plate in new steel-UHPC composite deck system.
引用
收藏
页数:15
相关论文
共 38 条
  • [1] Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement
    Ahn, Jin-Hee
    Lee, Chan-Goo
    Won, Jeong-Hun
    Kim, Sang-Hyo
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (10) : 1295 - 1307
  • [2] [Anonymous], 2016, P18 710 NATL ADDITIO
  • [3] AQSIQ S.A.C., 2010, GB/T 228.1-2010
  • [4] BEng SH, 2022, Eurocode4: design of composite steel and concrete structures, P10
  • [5] A review on Life Cycle Assessment, Life Cycle Energy Assessment and Life Cycle Carbon Emissions Assessment on buildings
    Chau, C. K.
    Leung, T. M.
    Ng, W. Y.
    [J]. APPLIED ENERGY, 2015, 143 : 395 - 413
  • [6] Dang W., 2016, World Earthquake Engineering
  • [7] Mechanical Behavior in Perfobond Rib Shear Connector with UHPC-Steel Composite Structure with Coarse Aggregate
    Duan, Maojun
    Zhang, Shiyu
    Wang, Xu
    Dong, Fenghui
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2020, 24 (04) : 1255 - 1267
  • [8] Reliability evaluation of flexural capacity design provision for UHPC beams reinforced with steel rebars/prestressing tendons
    Feng, Jiahui
    Shao, Xudong
    Qiu, Minghong
    Li, Huihui
    Gao, Xiang
    Huang, Zhonglin
    [J]. ENGINEERING STRUCTURES, 2024, 300
  • [9] Gao DY, 2004, Build Sci, V20, P69, DOI [10.13614/j.cnki.11-1962, DOI 10.13614/J.CNKI.11-1962]
  • [10] Investigation on structural performance of perfobond strip connector group in steel-concrete joints
    He, Shaohua
    Guan, Peidong
    Wang, Qiao
    Fang, Zhi
    Mosallam, Ayman
    [J]. ENGINEERING STRUCTURES, 2021, 242