Parametric laser rangefinder with a passive thermal stabilization system

被引:1
|
作者
Tikhonov, E., V [1 ]
Markushin, G. N. [1 ]
Koshelev, A., V [1 ]
Vekshin, Yu. A. [1 ]
Almazov, A. A. [1 ]
Shvalev, A., V [1 ]
Korotaev, V. V. [2 ]
机构
[1] Ural Opt & Mech Plant named E S Yalamov, Ekaterinburg, Russia
[2] ITMO Univ, St Petersburg, Russia
关键词
D O I
10.1364/JOT.90.000609
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Subject of study . The development of a small -sized pulsed laser rangefinder with a passive thermal stabilization system is studied. Objective . The objective is the creation of a prototype of a laser rangefinder generating pulsed laser radiation with a wavelength of 1 = ( 1.57 +/- 0.04 ) g m. Method . A theoretical study of the influence of the rangefinder operating wavelength on the propagation of laser radiation in the atmosphere and extinction losses was performed using the finite difference method in a time-nonstationary formulation. The mode composition of radiation was estimated using a standard numerical solution of the Fresnel-Kirchhoff diffraction integral. The methods of pyroelectric registration were used for the estimation of the energy parameters of laser radiation. Main results . A small -sized laser rangefinder generating laser radiation in the near-IR range at a wavelength of (1.57 +/- 0.04) g m with a pulse repetition rate of up to 20 Hz and pulse energy of up to 17 mJ was developed. The rangefinder emitter was constructed utilizing a composite stable semi-confocal optical resonator. Within one segment of the resonator, a nonlinear passive conversion of the radiation 1 = ( 1.064 +/- 0.025 ) g m emitted by an active medium based on a stoichiometric Nd:YAG single crystal led to the formation of a signal wave with a wavelength of 1 = ( 1.57 +/- 0.04 ) g m. Scientific novelty . The research demonstrates the possibility of maintaining stable generation with a temperature mismatch between the absorption spectrum of the active media and the emission spectrum of the laser diode bar by up to 22 nm, which makes it possible to eliminate the use of a thermal stabilization system for the diode bar. Practical significance . It is shown that radiation with a wavelength of 1 = ( 1.57 +/- 0.04 ) g m is preferable for tasks of pulsed laser ranging in comparison with radiation with a wavelength of 1 = ( 1.064 +/- 0.025 ) g m because there is less scattering on atmospheric aerosol. The active medium is pumped by a quasi -continuous wave multispectral array of laser diodes with a total average radiation pulse power of 2200 W, which makes it possible to abandon active thermal stabilization and optimize the mass and dimensional parameters of the product. (c) 2024 Optica Publishing Group
引用
收藏
页码:609 / 616
页数:8
相关论文
共 50 条
  • [1] Passive Thermal Stabilization
    Lipp, Markus
    Langenbach, Eckhard
    Saupe, Frank
    INTERNATIONAL OPTICAL DESIGN CONFERENCE 2014, 2014, 9293
  • [2] Receiving system of a pulsed laser rangefinder
    Golovkov, V. A.
    Potapova, N., I
    Rudenko, P. N.
    Stradov, B. G.
    JOURNAL OF OPTICAL TECHNOLOGY, 2020, 87 (11) : 688 - 692
  • [3] Temperature control for laser rangefinder system
    Jia, Fang-Xiu
    Ding, Zhen-Liang
    Yuan, Feng
    Zhong, Li
    Infrared and Laser Engineering, 2008, 37 (06) : 1016 - 1020
  • [4] Study of system sensitivity of laser rangefinder
    Wu, Huichun
    Wang, Jizhong
    Xu, Zhongsheng
    1996, (20):
  • [5] Design of Optical System for Laser Rangefinder
    Wang, W. C.
    SPORTS MATERIALS, MODELLING AND SIMULATION, 2011, 187 : 581 - 585
  • [6] The Manipulator of the Passive Optoelectronic Rangefinder as a Controlled System of Servomechanisms
    Cech, V.
    Cervenka, M.
    MECHATRONICS 2013: RECENT TECHNOLOGICAL AND SCIENTIFIC ADVANCES, 2014, : 17 - 24
  • [7] SYSTEM-DESIGN OF A PULSED LASER RANGEFINDER
    BURNS, HN
    CHRISTODOULOU, CG
    BOREMAN, GD
    OPTICAL ENGINEERING, 1991, 30 (03) : 323 - 329
  • [8] The Laser Rangefinder System in Quadrature Modem and Ambiguity Resolution
    Zhao Wen-cheng
    Xu Xian-ze
    Liu Pan-pan
    Cheng Wen-qiang
    Xu Feng-qiu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2017, 37 (02) : 659 - 664
  • [9] LASER WAVELENGTH STABILIZATION WITH A PASSIVE INTERFEROMETER
    LIPSETT, MS
    LEE, PH
    APPLIED OPTICS, 1966, 5 (05): : 823 - &
  • [10] Performance Verification of a Target Tracking System With a Laser Rangefinder
    Lee, Jihoon
    Lee, Suwon
    Lee, Youngjun
    Kim, Youdan
    Heo, Yongjun
    Yoon, Taedong
    IEEE ACCESS, 2021, 9 : 30993 - 31009