Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes

被引:2
|
作者
Li, Xinxin [1 ]
Song, Chunyuan [2 ]
Wang, Yong [3 ]
Wang, Jing [4 ]
Tang, Qiongyan [5 ]
Wu, Zheming [6 ]
Zhou, Yanwen [7 ]
Sun, Juan [8 ]
Jia, Yanhong [9 ]
Lin, Zhenlin [10 ]
Li, Shaowei [1 ,11 ]
机构
[1] Cent South Univ, Aier Sch Ophthalmol, Changsha 410015, Peoples R China
[2] Jinan Univ, Aier Eye Hosp, Guangzhou 510071, Peoples R China
[3] Wuhan AIER Eye Hosp, Wuhan 430063, Peoples R China
[4] Shenyang Aier Excellence Eye Hosp, Shenyang 110001, Peoples R China
[5] Changsha Aier Eye Hosp, Changsha 410015, Peoples R China
[6] Guangzhou Aier Eye Hosp, Guangzhou 510000, Peoples R China
[7] Liaoning Aier Eye Hosp, Shenyang 110003, Peoples R China
[8] Hubin Aier Eye Hosp, Binzhou 256600, Peoples R China
[9] Nanning Aier Eye Hosp, Nanning 530012, Peoples R China
[10] Fuzhou Aier Eye Hosp, Fuzhou 350000, Peoples R China
[11] Beijing Aier Intech Eye Hosp, Beijing 100021, Peoples R China
关键词
Intraocular lens power; Calculation; Formula; Extremely long axial length; Cataract surgery; PARTIAL COHERENCE INTERFEROMETRY; SWEPT-SOURCE OCT; AXIAL LENGTH; HIGH MYOPIA; IOL; CATARACT; BIOMETRY;
D O I
10.1007/s00417-024-06506-w
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the accuracy of 14 formulas in calculating intraocular lens (IOL) power in extremely long eyes with axial length (AL) over 30.0 mm. Methods In this retrospective study, 211 eyes (211 patients) with ALs > 30.0 mm were successfully treated with cataract surgery without complications. Ocular biometric parameters were obtained from IOLMaster 700. Fourteen formulas were evaluated using the optimized A constants: Barrett Universal II (BUII), Kane, Emmetropia Verifying Optical (EVO) 2.0, PEARL-DGS, T2, SRK/T, Holladay 1, Holladay 2, Haigis and Wang-Koch AL adjusted formulas (SRK/Tmodified-W/K, Holladay 1(modified-W/K), Holladay 1(NP-modified-W/K), Holladay 2(modified-W/K), Holladay 2(NP-modified-W/K)). The mean prediction error (PE) and standard deviation (SD), mean absolute errors (MAE), median absolute errors (MedAE), and the percentage of prediction errors (PEs) within +/- 0.25 D, +/- 0.50 D, +/- 1.00 D were analyzed. Results The Kane formula had the smallest MAE (0.43 D) and MedAE (0.34 D). The highest percentage of PE within +/- 0.25 D was for EVO 2.0 (37.91%) and the Holladay 1(NP-modified-W/K) formulas (37.91%). The Kane formula had the highest percentage of PEs in the range of +/- 0.50, +/- 0.75, +/- 1.00, and +/- 2.00 D. There was no significant difference in PEs within +/- 0.25, +/- 0.50 +/- 0.75 and +/- 1.00 D between BUII, Kane, EVO 2.0 and Wang-Koch AL adjusted formulas (P > .05) by using Cochran's Q test. The Holladay 2(modified-W/K) formula has the lowest percentage of hyperopic outcomes (29.38%). Conclusions The BUII, Kane, EVO 2.0 and Wang-Koch AL adjusted formulas have comparable accuracy for IOL power calculation in eyes with ALs > 30.0 mm.
引用
收藏
页码:3619 / 3628
页数:10
相关论文
共 50 条
  • [31] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Shi, Jingyi
    Zhu, Zehui
    Hu, Bin
    Qian, Shuyi
    Wang, Yalan
    Chang, Pingjun
    Zhao, Yun-e
    OPHTHALMOLOGY AND THERAPY, 2024, 13 (05) : 1321 - 1342
  • [32] How to choose the intraocular lens power calculation formulas in eyes with extremely long axial length? A systematic review and meta-analysis
    Li, Xiaoyu
    Wang, Xiaodong
    Liao, Xuan
    PLOS ONE, 2024, 19 (01):
  • [33] Effect of Segmented Optical Axial Length on the Performance of New-Generation Intraocular Lens Power Calculation Formulas in Extremely Long Eyes
    Goto, So
    Maeda, Naoyuki
    Uehara, Kota
    Ogawa, Keiko
    Matsumaru, Maki
    Sugiyama, Saori
    Ohnuma, Kazuhiko
    Lawu, Tjundewo
    Noda, Toru
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)
  • [34] Effect of Lens Vault on the Accuracy of Intraocular Lens Calculation Formulas in Shallow Anterior Chamber Eyes
    Yan, Chenxi
    Yao, Ke
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 233 : 57 - 67
  • [35] Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia
    Liu, Jiewei
    Wang, Li
    Chai, Feiyan
    Han, Yu
    Qian, Suqin
    Koch, Douglas D.
    Weikert, Mitchell P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 725 - 731
  • [36] Investigation of the myopic outcomes of the newer intraocular lens power calculation formulas in Korean patients with long eyes
    Kim, Jinchul
    Park, Joonsung
    Jo, Yoonjung
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [37] Intraocular lens power calculation formulas in Chinese eyes with high axial myopia
    Tsang, CSL
    Chong, GSL
    Yiu, EPF
    Ho, CK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1358 - 1364
  • [38] Effectiveness, Sensitivity, and Specificity of Intraocular Lens Power Calculation Formulas for Short Eyes
    Stopyra, Wiktor
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2022, 52 (03): : 201 - 207
  • [39] Comment on: Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Gonzalez-Lubcke, Eduardo
    Kahuam-Lopez, Nicolas
    Navas, Alejandro
    Ramirez-Miranda, Arturo
    Graue-Hernandez, Enrique O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 354 - 355
  • [40] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988