Efficiency Assessment on Roof Geometry and Trombe Wall Shape for Improving Buildings' Heating Performance

被引:3
作者
Dhahri, Maher [1 ,2 ,3 ]
Yuksel, Ahmet [4 ]
Aouinet, Hana [3 ]
Wang, Di [5 ]
Arici, Muslum [6 ,7 ]
Sammouda, Habib [2 ]
机构
[1] Univ Sousse, Higher Inst Appl Sci & Technol Sousse, BP 4003, Sousse, Tunisia
[2] Sousse Univ, High Sch Sci & Technol Hammam Sousse, Lab Energy & Mat LabEM LR11ES34, BP 4011, Sousse, Tunisia
[3] Aeronaut & Aerosp Engn Sch, Elisa Aerosp, 48 Rue Raspail, F-02100 Saint Quentin, France
[4] Yalova Univ, Yalova Vocat Sch, Elect & Energy Dept, TR-77200 Yalova, Turkiye
[5] Northeast Petr Univ, Sch Phys & Elect Engn, Daqing 163318, Peoples R China
[6] Kocaeli Univ, Engn Fac, Mech Engn Dept, TR-41001 Kocaeli, Turkiye
[7] Kocaeli Univ, Int Joint Lab Low Carbon & New Energy Nexus Res &, TR-41001 Kocaeli, Turkiye
关键词
buildings; computational fluid dynamics; heating performance; roof configuration; thermal comfort; Trombe wall; THERMAL PERFORMANCE; NUMERICAL-ANALYSIS; SIMULATION; COMFORT; IMPACT;
D O I
10.3390/buildings14051297
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It is crucial to consider structural design issues in Trombe wall (T-wall) buildings to promote more suitable indoor climates and thermal comfort standards. Therefore, the present study examined the impact of two different T-wall designs and six different roof types on the energy and operational efficiency of a building located in a low-temperature and high-humidity winter climate. Ansys-CFX 15.0 software was employed to simulate the thermal and fluid dynamics behavior of the T-wall system, and flow, thermal comfort, energy, and exergy analyses were conducted. Three-dimensional simulation results and the pertinent literature data showed a good level of agreement, and the accuracy of the model was ensured. Outcomes revealed an average air velocity variation of 0.186 m/s and maximum average indoor air temperature variation of 3.3 degrees C between the six roof geometries. The highest air speed (0.988 m/s) was recorded for the gambrel roof while the lowest one (0.802 m/s) was recorded for the typical flat roof. The shed roof right with a rounded T-wall was more comfortable for standing and sitting activity than the others for the two T-wall shapes, and, at Y = 0.6 m and Y = 1.1 m, the average predicted percentages of dissatisfied (PPD) values were 31 and 28%, respectively. Furthermore, it was determined in the study that solar radiation intensity and T-wall and roof geometries had a significant effect on energy and exergy efficiency, and high energy and exergy efficiencies were achieved at higher solar intensity values. The best energy and exergy efficiencies were obtained for the butterfly and shed roof configurations. This study can serve as a reference for the thermal environment design of buildings with T-walls.
引用
收藏
页数:25
相关论文
共 51 条
[1]   Experimental, analytical, and numerical investigation into the feasibility of integrating a passive Trombe wall into a single room [J].
Abdeen, Ahmed ;
Serageldin, Ahmed A. ;
Ibrahim, Mona G. E. ;
El-Zafarany, Abbas ;
Ookawara, Shinichi ;
Murata, Ryo .
APPLIED THERMAL ENGINEERING, 2019, 154 :751-768
[3]   Thermal performance of building roof elements [J].
Al-Sanea, SA .
BUILDING AND ENVIRONMENT, 2002, 37 (07) :665-675
[4]  
ASHRAE, 2017, 552017 ASHRAE
[5]   Evaluation of thermal performance and energy efficiency of a Trombe wall improved with dual phase change materials [J].
Askari, Minoo ;
Jahangir, Mohammad Hossein .
ENERGY, 2023, 284
[6]   Enhancement of natural convection for improvement of Trombe wall performance. An experimental study [J].
Bairi, A. ;
Martin-Garin, A. ;
Adeyeye, K. ;
She, K. ;
Millan-Garcia, J. A. .
ENERGY AND BUILDINGS, 2020, 211
[7]   CFD analyses for passive house with Trombe wall and impact to energy demand [J].
Bajc, Tamara ;
Todorovic, Maja N. ;
Svorcan, Jelena .
ENERGY AND BUILDINGS, 2015, 98 :39-44
[8]   A validated multi-physic model for the optimization of an innovative Trombe Wall for winter use [J].
Bevilacqua, Piero ;
Bruno, Roberto ;
Gallo, Sebastiano ;
Szyszka, Jerzy .
JOURNAL OF BUILDING ENGINEERING, 2024, 86
[9]   CFD Analysis for a New Trombe Wall Concept [J].
Bulmez, Alexandru Mihai ;
Brezeanu, Alin Ionut ;
Dragomir, George ;
Fratu, Mariana ;
Iordan, Nicolae Fani ;
Bolocan, Sorin Ionut ;
Rozorea, Lucian ;
Popa, Eugen Calin ;
Nastase, Gabriel .
BUILDINGS, 2024, 14 (03)
[10]   Numerical simulation of modified Trombe-Michel Walls with exergy and energy analysis [J].
Corasaniti, Sandra ;
Manni, Luca ;
Russo, Flavia ;
Gori, Fabio .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2017, 88 :269-276