Effectiveness and safety of MR-guided focused ultrasound thalamotomy in patients with essential tremor and low skull density ratio: a study of 101 cases

被引:7
作者
Hino, Sakae [1 ,2 ]
Maki, Futaba [1 ,2 ]
Yamaguchi, Toshio [3 ,4 ]
Kaburagi, Mayumi [1 ,2 ]
Nakano, Masayuki [5 ]
Iwamuro, Hirokazu [6 ]
Takasaki, Masahito [7 ]
Iijima, Ken [8 ]
Kanouchi, Masashi [9 ]
Sasanuma, Jinichi [5 ]
Watanabe, Kazuo [5 ]
Hasegawa, Yasuhiro [1 ,2 ]
Yamano, Yoshihisa [1 ,2 ]
机构
[1] St Marianna Univ, Dept Neurol, Sch Med, Kawasaki, Kanagawa, Japan
[2] Shin Yurigaoka Gen Hosp, Dept Hematol, Kawasaki, Kanagawa, Japan
[3] Int Acad Focused Ultrasound Therapy, Yokohama, Kanagawa, Japan
[4] Shin Yurigaoka Gen Hosp, Res Inst Diagnost Radiol, Kawasaki, Kanagawa, Japan
[5] Shin Yurigaoka Gen Hosp, Dept Neurosurg, Kawasaki, Kanagawa, Japan
[6] Juntendo Univ, Dept Neurosurg, Tokyo, Japan
[7] Shin Yurigaoka Gen Hosp, Dept Anesthesiol, Kawasaki, Kanagawa, Japan
[8] Saitama Sekishinkai Hosp, Dept Radiol, Saitama, Japan
[9] Shin Yurigaoka Gen Hosp, Dept Radiol, Kawasaki, Kanagawa, Japan
基金
日本学术振兴会;
关键词
magnetic resonance-guided focused ultrasound; thalamotomy; essential tremor; low skull density ratio; functional neurosurgery; EFFICIENCY;
D O I
10.3171/2023.11.JNS231799
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE The objective was to investigate the effectiveness and safety of MR-guided focused ultrasound (MRgFUS) treatment in patients with essential tremor, particularly those with low skull density ratio (SDR) and including those with very low SDR, and to identify the factors influencing treatment effectiveness and to provide insights into therapeutic ap- proaches for patients with lower SDR. METHODS Real-world data from 101 patients who underwent MRgFUS between July 2019 and March 2022 at a single institution were analyzed. Tremor severity was assessed using the Fahn-Tolosa-Marin Clinical Rating Scale for Tremor (CRST). The patients were categorized into quartile groups based on their mean SDR, and the characteristics, treatment effectiveness, treatment parameters, and adverse events were evaluated among these subgroups. RESULTS Patients were classified into 4 quartiles based on the mean SDR: quartile 1 (Q1) (SDR 0.26-0.37), Q2 (SDR 0.38-0.42), Q3 (SDR 0.43-0.49), and Q4 (SDR 0.50-0.75). MRgFUS significantly improved total CRST and tremor score across all SDR subgroups. Additionally, there were no significant differences in the improvement rates among the 4 subgroups. Analysis of the treatment parameters revealed that lower mean SDR was associated with lower target maximum temperature and smaller coagulation volume after focused ultrasound (FUS). Regarding adverse events, headache and nausea during FUS and facial and head edema on the day after surgery were more frequent in the Q1 subgroup (very low-SDR group). In contrast, numbness was more common in the Q4 subgroup. However, all these adverse events had resolved by the 3-month follow-up except numbness. CONCLUSIONS This study suggested that MRgFUS is effective and safe for patients with medication-resistant essential tremor, including those with very low mean SDR. However, the very low-SDR group had insufficient temperature elevation at the target site compared with the high-SDR group, suggesting the need for a different strategy. Notably, with careful adjustments and considerations, positive outcomes can still be achieved in patients with very low SDR. Therefore, very low SDR should not be considered an absolute exclusion criterion because it is expected to increase the number of patients who benefit from MRgFUS.
引用
收藏
页码:212 / 220
页数:9
相关论文
共 19 条
[1]   The relevance of skull density ratio in selecting candidates for transcranial MR-guided focused ultrasound [J].
Boutet, Alexandre ;
Gwun, Dave ;
Gramer, Robert ;
Ranjan, Manish ;
Elias, Gavin J. B. ;
Tilden, David ;
Huang, Yuexi ;
Li, Stanley Xiangyu ;
Davidson, Benjamin ;
Lu, Hua ;
Tyrrell, Pascal ;
Jones, Ryan M. ;
Fasano, Alfonso ;
Hynynen, Kullervo ;
Kucharczyk, Walter ;
Schwartz, Michael L. ;
Lozano, Andres M. .
JOURNAL OF NEUROSURGERY, 2020, 132 (06) :1785-1791
[2]   Factors associated with successful magnetic resonance guided focused ultrasound treatment: efficiency of acoustic energy delivery through the skull [J].
Chang, Won Seok ;
Jung, Hyun Ho ;
Zadicario, Eyal ;
Rachmilevitch, Itay ;
Tlusty, Tal ;
Vitek, Shuki ;
Chang, Jin Woo .
JOURNAL OF NEUROSURGERY, 2016, 124 (02) :411-416
[3]   Impact of skull density ratio on efficacy and safety of magnetic resonance-guided focused ultrasound treatment of essential tremor [J].
D'Souza, Marissa ;
Chen, Kevin S. ;
Rosenberg, Jarrett ;
Elias, W. Jeffrey ;
Eisenberg, Howard M. ;
Gwinn, Ryder ;
Taira, Takaomi ;
Chang, Jin Woo ;
Lipsman, Nir ;
Krishna, Vibhor ;
Igase, Keiji ;
Yamada, Kazumichi ;
Kishima, Haruhiko ;
Cosgrove, Rees ;
Rumia, Jordi ;
Kaplitt, Michael G. ;
Hirabayashi, Hidehiro ;
Nandi, Dipankar ;
Henderson, Jaimie M. ;
Pauly, Kim Butts ;
Dayan, Mor ;
Halpern, Casey H. ;
Ghanouni, Pejman .
JOURNAL OF NEUROSURGERY, 2020, 132 (05) :1392-1397
[4]   A Randomized Trial of Focused Ultrasound Thalamotomy for Essential Tremor [J].
Elias, W. Jeffrey ;
Lipsman, Nir ;
Ondo, William G. ;
Ghanouni, Pejman ;
Kim, Young G. ;
Lee, Wonhee ;
Schwartz, Michael ;
Hynynen, Kullervo ;
Lozano, Andres M. ;
Shah, Binit B. ;
Huss, Diane ;
Dallapiazza, Robert F. ;
Gwinn, Ryder ;
Witt, Jennifer ;
Ro, Susie ;
Eisenberg, Howard M. ;
Fishman, Paul S. ;
Gandhi, Dheeraj ;
Halpern, Casey H. ;
Chuang, Rosalind ;
Pauly, Kim Butts ;
Tierney, Travis S. ;
Hayes, Michael T. ;
Cosgrove, G. Rees ;
Yamaguchi, Toshio ;
Abe, Keiichi ;
Taira, Takaomi ;
Chang, Jin W. .
NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (08) :730-739
[5]   A Pilot Study of Focused Ultrasound Thalamotomy for Essential Tremor [J].
Elias, W. Jeffrey ;
Huss, Diane ;
Voss, Tiffini ;
Loomba, Johanna ;
Khaled, Mohamad ;
Zadicario, Eyal ;
Frysinger, Robert C. ;
Sperling, Scott A. ;
Wylie, Scott ;
Monteith, Stephen J. ;
Druzgal, Jason ;
Shah, Binit B. ;
Harrison, Madaline ;
Wintermark, Max .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (07) :640-648
[6]   Volumetric analysis of magnetic resonance-guided focused ultrasound thalamotomy lesions [J].
Harary, Maya ;
Essayed, Walid I. ;
Valdes, Pablo A. ;
McDannold, Nathan ;
Cosgrove, G. Rees .
NEUROSURGICAL FOCUS, 2018, 44 (02)
[7]   Characteristics of Pain During MRI-Guided Focused Ultrasound Thalamotomy [J].
He, Xin ;
Oshino, Satoru ;
Hosomi, Koichi ;
Kanemoto, Manabu ;
Tani, Naoki ;
Kishima, Haruhiko .
NEUROSURGERY, 2023, 93 (02) :358-365
[8]   Predicting lesion size by accumulated thermal dose in MR-guided focused ultrasound for essential tremor [J].
Huang, Yuexi ;
Lipsman, Nir ;
Schwartz, Michael L. ;
Krishna, Vibhor ;
Sammartino, Francesco ;
Lozano, Andres M. ;
Hynynen, Kullervo .
MEDICAL PHYSICS, 2018, 45 (10) :4704-4710
[9]   Predictors of thermal increase in magnetic resonance-guided focused ultrasound treatment for essential tremor: histogram analysis of skull density ratio values for 1024 elements [J].
Iijima, Ken ;
Yokota, Hajime ;
Yamaguchi, Toshio ;
Nakano, Masayuki ;
Ouchi, Takahiro ;
Maki, Futaba ;
Takasaki, Masahito ;
Shimizu, Yasuhiro ;
Hori, Hiroki ;
Iwamuro, Hirokazu ;
Sasanuma, Jinichi ;
Watanabe, Kazuo ;
Uno, Takashi .
JOURNAL OF NEUROSURGERY, 2022, 136 (05) :1381-1386
[10]   A study of novel bilateral thermal capsulotomy with focused ultrasound for treatment-refractory obsessive-compulsive disorder: 2-year follow-up [J].
Kim, Se Joo ;
Roh, Daeyoung ;
Jung, Hyun Ho ;
Chang, Won Seok ;
Kim, Chan-Hyung ;
Chang, Jin Woo .
JOURNAL OF PSYCHIATRY & NEUROSCIENCE, 2018, 43 (05) :327-337