High-glide refrigerant blends in high-temperature heat pumps: Part 1-Coefficient of performance

被引:1
作者
Brendel, Leon P. M. [1 ]
Bernal, Silvan N. [1 ]
Widmaier, Philip [2 ]
Roskosch, Dennis [2 ]
Arpagaus, Cordin [1 ]
Bardow, Andre [2 ]
Bertsch, Stefan S. [1 ]
机构
[1] Eastern Switzerland Univ Appl Sci, Inst Energy Syst, CH-9471 Buchs, Switzerland
[2] Swiss Fed Inst Technol, Energy & Proc Syst Engn, CH-8092 Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
COP; High-temperature heat pump; Temperature glide; Refrigerant blends; Refrigerant mixtures; THERMODYNAMIC PROPERTIES; HYDROCARBON MIXTURES; REPLACE HFC-134A;
D O I
10.1016/j.ijrefrig.2024.05.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
Climate change necessitates the reduction of primary energy consumption. Industrial heat pumps can contribute by replacing oil and gas fired boilers in various applications. To cater the application, heat pumps must often impose temperature differences of 25 K or more to the heat source and heat sink, causing great irreversibility if evaporation and condensation occur at constant temperatures. Many theoretical studies suggest that high -glide refrigerant mixtures designed to match the temperature differences have a superior COP for such applications. In contrast to the numerous theoretical studies, systematic experimental studies are missing. This study tests highglide mixtures at varying compositions at constant operating conditions. COP improvements of 16 % are shown comparing the best mixture against the best pure fluid. The improvement was established despite a significant degradation in the heat transfer coefficient, which could presumably be alleviated with larger heat exchangers. Additional parametric studies are conducted on the temperature differences of heat sink and source as well as the temperature level. The results show that mixtures not only outperform pure fluids at certain operating conditions but can maintain a higher COP across varying operating conditions. The binary and ternary mixtures in this study have glides between 10 and 40 K and consist of R1336mzz(Z), R1233zd(E), R1224yd(Z), R1234yf and R32.
引用
收藏
页码:84 / 96
页数:13
相关论文
共 42 条
  • [1] Akasaka R., 2017, EUR C THERM PROP
  • [2] Arpagaus C., 2018, PURD C
  • [3] Arpagaus C, 2020, REFR SCI T, P342, DOI 10.18462/iir.rankine.2020.1168
  • [4] Besbes K., 2015, Refrig. Sci. Technol., P3769, DOI [10.18462/iir.icr.2015.0599, DOI 10.18462/IIR.ICR.2015.0599]
  • [5] Environmental risk assessment of trifluoroacetic acid
    Boutonnet, JC
    Bingham, P
    Calamari, D
    de Rooij, C
    Franklin, J
    Kawano, T
    Libre, JM
    McCulloch, A
    Malinverno, G
    Odom, JM
    Rusch, GM
    Smythe, K
    Sobolev, I
    Thompson, R
    Tiedje, JM
    [J]. HUMAN AND ECOLOGICAL RISK ASSESSMENT, 1999, 5 (01): : 59 - 124
  • [6] Brendel L.P.M., 2023, INT C REFR
  • [7] Brendel L.P.M., 2023, P 13 INT C COMPR THE, DOI [10.1007/978-3-031-42663-6_60, DOI 10.1007/978-3-031-42663-6_60]
  • [8] Brendel L.P.M., 2023, DKV TAG
  • [9] Thermo-economic investigation and multi-objective optimization of a novel enhanced heat pump system with zeotropic mixture using NSGA-II
    Cao, Yan
    Dhahad, Hayder A.
    Mohamed, Abdeliazim Mustafa
    Anqi, Ali E.
    [J]. APPLIED THERMAL ENGINEERING, 2021, 194
  • [10] De Carlan F, 2019, 2 C HIGH TEMP HEAT P, P1