Rapid pulmonary 129Xe ventilation MRI of discharged COVID-19 patients with zigzag sampling

被引:6
作者
Fang, Yuan [1 ,2 ]
Li, Haidong [2 ,3 ]
Shen, Luyang [2 ]
Zhang, Ming [2 ,3 ]
Luo, Ming [2 ]
Li, Hongchuang [2 ,3 ]
Rao, Qiuchen [2 ]
Chen, Qi [2 ,3 ]
Li, Yecheng [2 ,3 ]
Li, Zimeng [1 ,2 ]
Zhao, Xiuchao [2 ,3 ]
Shi, Lei [2 ,3 ]
Zhou, Qian [2 ]
Han, Yeqing [2 ,3 ]
Guo, Fumin [2 ]
Zhou, Xin [2 ,3 ,4 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Phys, Wuhan, Peoples R China
[2] Huazhong Univ Sci & Technol, Chinese Acad Sci, Innovat Acad Precis Measurement Sci & Technol, Wuhan Inst Phys & Math,Key Lab Magnet Resonance Bi, Wuhan 430071, Peoples R China
[3] Univ Chinese Acad Sci, Beijing, Peoples R China
[4] Hainan Univ, Sch Biomed Engn, Hainan, Peoples R China
基金
中国国家自然科学基金;
关键词
hyperpolarized Xe-129; lung; ventilation MRI; zigzag sampling; HYPERPOLARIZED XE-129; HEALTHY-VOLUNTEERS; HE-3; TOLERABILITY; ACQUISITION; DISEASE; ASTHMA; SAFETY; EPI;
D O I
10.1002/mrm.30120
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To demonstrate the feasibility of zigzag sampling for 3D rapid hyperpolarized Xe-129 ventilation MRI in human. Methods Zigzag sampling in one direction was combined with gradient-recalled echo sequence (GRE-zigzag-Y) to acquire hyperpolarized Xe-129 ventilation images. Image quality was compared with a balanced SSFP (bSSFP) sequence with the same spatial resolution for 12 healthy volunteers (HVs). For another 8 HVs and 9 discharged coronavirus disease 2019 subjects, isotropic resolution Xe-129 ventilation images were acquired using zigzag sampling in two directions through GRE-zigzag-YZ. Xe-129 ventilation defect percent (VDP) was quantified for GRE-zigzag-YZ and bSSFP acquisitions. Relationships and agreement between these VDP measurements were evaluated using Pearson correlation coefficient (r) and Bland-Altman analysis. Results For 12 HVs, GRE-zigzag-Y and bSSFP required 2.2 s and 10.5 s, respectively, to acquire Xe-129 images with a spatial resolution of 3.96 x 3.96 x 10.5 mm(3). Structural similarity index, mean absolute error, and Dice similarity coefficient between the two sets of images and ventilated lung regions were 0.85 +/- 0.03, 0.0015 +/- 0.0001, and 0.91 +/- 0.02, respectively. For another 8 HVs and 9 coronavirus disease 2019 subjects, Xe-129 images with a nominal spatial resolution of 2.5 x 2.5 x 2.5 mm(3) were acquired within 5.5 s per subject using GRE-zigzag-YZ. VDP provided by GRE-zigzag-YZ was strongly correlated (R-2 = 0.93, p < 0.0001) with that generated by bSSFP with minimal biases (bias = -0.005%, 95% limit-of-agreement = [-0.414%, 0.424%]). Conclusion Zigzag sampling combined with GRE sequence provides a way for rapid Xe-129 ventilation imaging.
引用
收藏
页码:956 / 966
页数:11
相关论文
共 52 条
  • [31] Protocols for multi-site trials using hyperpolarized 129Xe MRI for imaging of ventilation, alveolar-airspace size, and gas exchange: A position paper from the 129Xe MRI clinical trials consortium
    Niedbalski, Peter J.
    Hall, Chase S.
    Castro, Mario
    Eddy, Rachel L.
    Rayment, Jonathan H.
    Svenningsen, Sarah
    Parraga, Grace
    Zanette, Brandon
    Santyr, Giles E.
    Thomen, Robert P.
    Stewart, Neil J.
    Collier, Guilhem J.
    Chan, Ho-Fung
    Wild, Jim M.
    Fain, Sean B.
    Miller, G. Wilson
    Mata, Jaime F.
    Mugler, John P., III
    Driehuys, Bastiaan
    Willmering, Matthew M.
    Cleveland, Zackary, I
    Woods, Jason C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (06) : 2966 - 2986
  • [32] High Resolution Diffusion-Weighted Imaging Using Readout-Segmented Echo-Planar Imaging, Parallel Imaging and a Two-Dimensional Navigator-Based Reacquisition
    Porter, David A.
    Heidemann, Robin M.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (02) : 468 - 475
  • [33] Optimizing 3D noncartesian gridding reconstruction for hyperpolarized 129Xe MRIfocus on preclinical applications
    Robertson, Scott H.
    Virgincar, Rohan S.
    He, Mu
    Freeman, Matthew S.
    Kaushik, Suryanarayanan S.
    Driehuys, Bastiaan
    [J]. CONCEPTS IN MAGNETIC RESONANCE PART A, 2015, 44 (04) : 190 - 202
  • [34] Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    Sodickson, DK
    Manning, WJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (04) : 591 - 603
  • [35] Initial feasibility and challenges of hyperpolarized 129Xe MRI in neonates with bronchopulmonary dysplasia
    Stewart, Neil J.
    Higano, Nara S.
    Mukthapuram, Shanmukha
    Willmering, Matthew M.
    Loew, Wolfgang
    West, Michael
    Arnsperger, Anita
    Pratt, Ronald
    Rao, Madhwesha R.
    Schulte, Rolf F.
    Wild, Jim M.
    Woods, Jason C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (06) : 2420 - 2431
  • [36] Comparison of 3He and 129Xe MRI for Evaluation of Lung Microstructure and Ventilation at 1.5T
    Stewart, Neil J.
    Chan, Ho-Fung
    Hughes, Paul J. C.
    Horn, Felix C.
    Norquay, Graham
    Rao, Madhwesha
    Yates, Denise P.
    Ireland, Rob H.
    Hatton, Matthew Q.
    Tahir, Bilal A.
    Ford, Paul
    Swift, Andrew J.
    Lawson, Rod
    Marshall, Helen
    Collier, Guilhem J.
    Wild, Jim M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2018, 48 (03) : 632 - 642
  • [37] Hyperpolarized 3He and 129Xe MRI: Differences in Asthma Before Bronchodilation
    Svenningsen, Sarah
    Kirby, Miranda
    Starr, Danielle
    Leary, Del
    Wheatley, Andrew
    Maksym, Geoffrey N.
    McCormack, David G.
    Parraga, Grace
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (06) : 1521 - 1530
  • [38] Hyperpolarized 129Xe for investigation of mild cystic fibrosis lung disease in pediatric patients
    Thomen, Robert P.
    Walkup, Laura L.
    Roach, David J.
    Cleveland, Zackary I.
    Clancy, John P.
    Woods, Jason C.
    [J]. JOURNAL OF CYSTIC FIBROSIS, 2017, 16 (02) : 275 - 282
  • [39] N4ITK: Improved N3 Bias Correction
    Tustison, Nicholas J.
    Avants, Brian B.
    Cook, Philip A.
    Zheng, Yuanjie
    Egan, Alexander
    Yushkevich, Paul A.
    Gee, James C.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (06) : 1310 - 1320
  • [40] Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease
    Virgincar, Rohan S.
    Cleveland, Zackary I.
    Kaushik, S. Sivaram
    Freeman, Matthew S.
    Nouls, John
    Cofer, Gary P.
    Martinez-Jimenez, Santiago
    He, Mu
    Kraft, Monica
    Wolber, Jan
    McAdams, H. Page
    Driehuys, Bastiaan
    [J]. NMR IN BIOMEDICINE, 2013, 26 (04) : 424 - 435