Shock-tube tests on conventional windows: Exploring retrofit concepts for enhanced blast protection

被引:1
作者
Andrae, Matthias [1 ]
Kastenmeier, Andreas [2 ]
Gebhardt, Jakob [2 ]
Ehrlich, Ingo [2 ]
Gebbeken, Norbert [1 ]
机构
[1] Univ Bundeswehr Munich, RISK Res Ctr, Res Grp BauProtect, Werner Heisenberg Weg 39, D-85577 Neubiberg, Germany
[2] Ostbayer TH Regensburg, Lab Composite Technol, Regensburg, Germany
关键词
Experiment; window; protection; retrofitting; blast; anti-shatter films; shock-tube; glass fiber-reinforced polymer;
D O I
10.1177/20414196241284297
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ensuring blast protection for existing buildings, especially addressing the vulnerability of conventional windows, is a significant challenge. Such unprotected windows can shatter even with moderate blast loads, posing a substantial risk of injury to occupants. This article discusses experimental research on enhancing the blast protection of single casement windows with insulating glass units and frames made of unplasticized polyvinyl chloride (uPVC). A retrofit concept using anti-shatter films, metallic sash reinforcements, adhesive bonding of the glazing to the sash frame, and a burglary resistance fitting-system was developed and tested in an explosion-driven shock-tube. Moreover, novel patches made of glass fiber-reinforced polymer applied to the corners of the window frames have been tested and proven effective in providing additional strength to the window. The study concludes that the tested combination of retrofit measures can significantly reduce hazards from window fragments without compromising functionality or aesthetics.
引用
收藏
页码:202 / 221
页数:20
相关论文
共 23 条
[1]   Mitigating Blast Hazards: Experimental Evaluation of Anti-Shatter Films and Catcher-Cable Systems on Conventional Windows [J].
Andrae, Matthias ;
van der Woerd, Jan Dirk ;
Wagner, Matthias ;
Pietzsch, Achim ;
Gebbeken, Norbert .
BUILDINGS, 2024, 14 (03)
[2]  
[Anonymous], 2010, Design of Blast Resistant Buildings in Petrochemical Facilities, V2nd
[3]  
Bedon C., 2014, JRC94930 COMP EXISTI
[4]   Multistep Experimental Calibration of Mechanical Parameters for Modelling Multilayer Antishatter Safety Films in Structural Glass Protection [J].
Bedon, Chiara ;
Mattei, Silvana .
MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
[5]  
Bergstrom J. S., 2015, Mechanics of solid polymers. Theory and computational modeling
[6]   Acoustic emission of material damages in glass fibre-reinforced plastics [J].
Bohmann, T. ;
Schlamp, M. ;
Ehrlich, I. .
COMPOSITES PART B-ENGINEERING, 2018, 155 :444-451
[7]  
Cormie D., 2019, BLAST EFFECTS BUILDI
[8]  
Fletcher E R., 1980, Glass fragment hazard from windows broken by airblast
[9]  
Fletcher ER., 1974, MINUTES 16 EXPLOSIVE
[10]   Approximating a far-field blast environment in an advanced blast simulator for explosion resistance testing [J].
Gan, Edward Chern Jinn ;
Remennikov, Alex ;
Ritzel, David ;
Uy, Brian .
INTERNATIONAL JOURNAL OF PROTECTIVE STRUCTURES, 2020, 11 (04) :468-493