Proximal cementation of a collarless polished tapered hip stem: biomechanical analysis using a validated finite element model

被引:0
|
作者
Ling, Carol Sze Yee [1 ]
Izmin, Aiman [2 ]
Todo, Mitsugu [2 ,3 ]
Merican, Azhar M. [1 ]
Chong, Desmond Y. R. [1 ,4 ]
机构
[1] Univ Malaya, Fac Med, Dept Orthopaed Surg, Kuala Lumpur, Malaysia
[2] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Fukuoka, Japan
[3] Kyushu Univ, Res Inst Appl Mech, Fukuoka, Japan
[4] Singapore Inst Technol, Engn Cluster, 10 Dover Dr, Singapore 138683, Singapore
关键词
Total hip replacement; Finite element analysis; Cemented fixation; Proximal cementing; Validated FE model; FEMORAL STEM; ARTHROPLASTY; FRACTURE; PREDICTION; PATTERNS; STRENGTH; BEHAVIOR; SURFACE; STRAIN; VARUS;
D O I
10.1007/s11517-024-03152-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Total hip replacement (THR) with cemented stem is a common procedure for patients with hip osteoarthritis. When primary THR fails, removal of the cement is problematic and poses challenges during revision surgeries. The possibility of proximal partial cementing of the hip stem was explored to mitigate the problem. 3D finite element analysis was performed to investigate the feasibility of reduced cement length for effective implant fixation and load transmission. Three levels of cement reduction (40 mm, 80 mm, and 100 mm) in the femoral stem were evaluated. All models were assigned loadings of peak forces acting on the femur during walking and stair climbing. The experimental and predicted max/min principal bone strains were fitted into regression models and showed good correlations. FE results indicated stress increment in the femoral bone, stem, and cement due to cement reduction. A notable increase of bone stress was observed with large cement reduction of 80-100 mm, particularly in Gruen zones 3 and 5 during walking and Gruen zones 3 and 6 during stair climbing. The increase of cement stresses could be limited to 11% with a cement reduction of 40 mm. The findings suggested that a 40-mm cement reduction in hip stem fixation was desirable to avoid unwanted complications after cemented THR.
引用
收藏
页码:3531 / 3542
页数:12
相关论文
共 50 条
  • [41] New Hip Prosthesis Design and Evaluation with Using Finite Element Analysis
    Celik, Talip
    Kisioglu, Yasin
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2022, 25 (02): : 563 - 567
  • [42] Use of DXA-based finite element analysis of the proximal femur in a longitudinal study of hip fracture
    Naylor, Kim E.
    McCloskey, Eugene V.
    Eastell, Richard
    Yang, Lang
    JOURNAL OF BONE AND MINERAL RESEARCH, 2013, 28 (05) : 1014 - 1021
  • [43] Finite Element Analysis on the Hollow Porous Design at the Proximal End of Cementless Femoral Prosthesis Stem
    He, S.
    Zhu, J.
    Zhao, J.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (09) : 1276 - 1280
  • [44] Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis
    Massin, P
    Astoin, E
    Lavaste, F
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2003, 89 (02): : 134 - 143
  • [45] Static, Transient, and Fatigue Design and Analysis of a Hip Femoral Stem Using the Finite Element Method
    Anticona-Valderrama, Daniela Milagros
    Serna-Landivar, Jose L.
    Algoner, William C.
    Miranda, Manuel Lopez
    Garcia-Alvarez, Maria Ysabel
    Landivar, Leslie Katerine Serna
    INTERNATIONAL JOURNAL OF ONLINE AND BIOMEDICAL ENGINEERING, 2024, 20 (16) : 89 - 102
  • [46] Biomechanical Characteristics of the Femoral Isthmus during Total Hip Arthroplasty in Patients with Adult Osteoporosis and Developmental Dysplasia of the Hip: A Finite Element Analysis
    Sun, Jianzhong
    Zhang, Rupeng
    Liu, Shenghang
    Zhao, Yuqi
    Mao, Genwen
    Bian, Weiguo
    ORTHOPAEDIC SURGERY, 2022, 14 (11) : 3019 - 3027
  • [47] Biomechanical analysis and design of a dynamic spinal fixator using topology optimization: a finite element analysis
    Lin, Hung-Ming
    Liu, Chien-Lin
    Pan, Yung-Ning
    Huang, Chang-Hung
    Shih, Shih-Liang
    Wei, Shun-Hwa
    Chen, Chen-Sheng
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52 (05) : 499 - 508
  • [48] Dynamic finite element analysis of hip replacement edge loading: Balancing precision and run time in a challenging model
    Etchels, Lee
    Wang, Lin
    Thompson, Jonathan
    Wilcox, Ruth
    Jones, Alison
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 143
  • [49] Biomechanical evaluation of an improved PFNA fixation devices for intertrochanteric hip fracture with finite element analysis
    Jiang, Ziwei
    Hu, Qunsheng
    Zhao, Jingtao
    Lao, Yongsheng
    Pang, Zhihui
    Dong, Hang
    Huang, Peizhen
    Zheng, Xiaohui
    Huang, Feng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (10): : 14888 - 14894
  • [50] Biomechanical study of tarsometatarsal joint fusion using finite element analysis
    Wang, Yan
    Li, Zengyong
    Zhang, Ming
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (11) : 1394 - 1400