Proximal cementation of a collarless polished tapered hip stem: biomechanical analysis using a validated finite element model

被引:0
|
作者
Ling, Carol Sze Yee [1 ]
Izmin, Aiman [2 ]
Todo, Mitsugu [2 ,3 ]
Merican, Azhar M. [1 ]
Chong, Desmond Y. R. [1 ,4 ]
机构
[1] Univ Malaya, Fac Med, Dept Orthopaed Surg, Kuala Lumpur, Malaysia
[2] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Fukuoka, Japan
[3] Kyushu Univ, Res Inst Appl Mech, Fukuoka, Japan
[4] Singapore Inst Technol, Engn Cluster, 10 Dover Dr, Singapore 138683, Singapore
关键词
Total hip replacement; Finite element analysis; Cemented fixation; Proximal cementing; Validated FE model; FEMORAL STEM; ARTHROPLASTY; FRACTURE; PREDICTION; PATTERNS; STRENGTH; BEHAVIOR; SURFACE; STRAIN; VARUS;
D O I
10.1007/s11517-024-03152-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Total hip replacement (THR) with cemented stem is a common procedure for patients with hip osteoarthritis. When primary THR fails, removal of the cement is problematic and poses challenges during revision surgeries. The possibility of proximal partial cementing of the hip stem was explored to mitigate the problem. 3D finite element analysis was performed to investigate the feasibility of reduced cement length for effective implant fixation and load transmission. Three levels of cement reduction (40 mm, 80 mm, and 100 mm) in the femoral stem were evaluated. All models were assigned loadings of peak forces acting on the femur during walking and stair climbing. The experimental and predicted max/min principal bone strains were fitted into regression models and showed good correlations. FE results indicated stress increment in the femoral bone, stem, and cement due to cement reduction. A notable increase of bone stress was observed with large cement reduction of 80-100 mm, particularly in Gruen zones 3 and 5 during walking and Gruen zones 3 and 6 during stair climbing. The increase of cement stresses could be limited to 11% with a cement reduction of 40 mm. The findings suggested that a 40-mm cement reduction in hip stem fixation was desirable to avoid unwanted complications after cemented THR.
引用
收藏
页码:3531 / 3542
页数:12
相关论文
共 50 条
  • [1] Biomechanical analysis of proximal tibia bone grafting and the effect of the size of osteotomy using a validated finite element model
    Ng, David Q. K.
    Lim, Chin Tat
    Ramruttun, Amit K.
    Tan, Ken Jin
    Wang, Wilson
    Chong, Desmond Y. R.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (08) : 1823 - 1832
  • [2] A Multi-factor Analysis of Revision in Total Hip Replacement Using the Collarless-Polished-Tapered Stems with Different Cups
    Hong, Yu
    Johnston, Linda
    Wang, Weijie
    ORTHOPAEDIC SURGERY, 2023, 15 (07) : 1870 - 1883
  • [3] Biomechanical Effects of the Porous Structure of Gyroid and Voronoi Hip Implants: A Finite Element Analysis Using an Experimentally Validated Model
    Salaha, Zatul Faqihah Mohd
    Ammarullah, Muhammad Imam
    Abdullah, Nik Nur Ain Azrin
    Aziz, Aishah Umairah Abd
    Gan, Hong-Seng
    Abdullah, Abdul Halim
    Kadir, Mohammed Rafiq Abdul
    Ramlee, Muhammad Hanif
    MATERIALS, 2023, 16 (09)
  • [4] Biomechanical Analysis of Hip Replacement Stem Design: A Finite Element Analysis
    Azbari, Zahra Shamsipour
    Rad, Mohadese Rajaei
    Nahvinejad, Amirreza
    Gilakjani, Hasan Asadi
    Khorsandi, Mohammad
    2022 29TH NATIONAL AND 7TH INTERNATIONAL IRANIAN CONFERENCE ON BIOMEDICAL ENGINEERING, ICBME, 2022, : 305 - 309
  • [5] A Biomechanical and Finite Element Analysis of Femoral Neck Notching During Hip Resurfacing
    Davis, Edward T.
    Olsen, Michael
    Zdero, Rad
    Papini, Marcello
    Waddell, James P.
    Schemitsch, Emil H.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (04):
  • [6] Biomechanical Analysis of Human Femur using Finite Element Method: A Review Study
    Mishra, Raji Nareliya
    Singh, Manvandra Kumar
    Kumar, Veerendra
    MATERIALS TODAY-PROCEEDINGS, 2022, 56 : 384 - 389
  • [7] Biomechanical Analysis of Orbital Development: A Finite Element Analysis by an Experimentally Validated Model
    Wang, Mingyang
    Jiang, Xue
    Song, Dongyu
    Li, Dongmei
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (05) : 1576 - 1580
  • [8] Biomechanical finite element analysis of bone cemented hip crack initiation according to stem design
    Byeongsoo Kim
    Byungyoung Moon
    Junghong Park
    Journal of Mechanical Science and Technology, 2006, 20 : 2168 - 2177
  • [9] Biomechanical finite element analysis of bone cemented hip crack initiation according to stem design
    Kim, Byeongsoo
    Moon, Byungyoung
    Park, Junghong
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2006, 20 (12) : 2168 - 2177
  • [10] Biomechanical Behavior of an Hydroxyapatite-Coated Traditional Hip Stem and a Short One of Similar Design: Comparative Study Using Finite Element Analysis
    Gomez-Vallejo, Jesus
    Roces-Garcia, Jorge
    Moreta, Jesus
    Donaire-Hoyas, Daniel
    Gayoso, Oscar
    Marques-Lopez, Fernando
    Albareda, Jorge
    ARTHROPLASTY TODAY, 2021, 7 : 167 - 176