Development of a novel DGT passive sampler for measuring polycyclic aromatic hydrocarbons in aquatic systems

被引:5
作者
Rong, Qiuyu [1 ]
Li, Yanying [2 ]
Luo, Jun [3 ]
Yan, Liying [3 ]
Jones, Kevin C. [1 ]
Zhang, Hao [1 ]
机构
[1] Univ Lancaster, Lancaster Environm Ctr, Lancaster LA1 4YQ, England
[2] Dalian Maritime Univ, Coll Environm Sci & Engn, Dalian 116023, Liaoning, Peoples R China
[3] Nanjing Univ, Sch Environm, State Key Lab Pollut Control & Resource Reuse, Nanjing 210023, Jiangsu, Peoples R China
关键词
Diffusive gradients in thin-films (DGT); Passive sampler; Polycyclic aromatic hydrocarbons; Molecularly imprinted polymer (MIP); Aquatic environment; THIN-FILMS TECHNIQUE; IN-SITU MEASUREMENTS; DIFFUSIVE GRADIENTS; ORGANIC POLLUTANTS; WATER SAMPLER; WASTE-WATER; PAHS; METALS; BIOAVAILABILITY; TEMPERATURE;
D O I
10.1016/j.jhazmat.2024.134199
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Polycyclic aromatic hydrocarbons (PAHs) are priority pollutants and need to be measured reliably in waters and other media, to understand their sources, fate, behaviour and to meet regulatory monitoring requirements. Conventional water sampling requires large water volumes, time-consuming pre-concentration and clean-up and is prone to analyte loss or contamination. Here, for the first time, we developed and validated a novel diffusive gradients in thin-films (DGT) passive sampler for PAHs. Based on the well-known DGT principles, the sampler pre-concentrates PAHs with typical deployment times of days/weeks, with minimal sample handling. For the first time, DGT holding devices made of metal and suitable for sampling hydrophobic organic compounds were designed and tested. They minimize sorption and sampling lag times. Following tests on different binding layer resins, a MIP-DGT was preferred - the first time applying MIP for PAHs. It samples PAHs independent of pH (3.9 8.1), ionic strength (0.01 0.5 M) and dissolved organic matter <20 mg L-1, making it suitable for appli-cations across a wide range of environments. Field trials in river water and wastewater demonstrated that DGT is a convenient and reliable tool for monitoring labile PAHs, readily achieving quantitative detection of environ-mental levels (sub-ng and ng/L range) when coupled with conventional GC-MS or HPLC. Environmental implications: PAHs are carcinogenic and genotoxic compounds. They are environmentally ubiq-uitous and must be monitored in waters and other media. This study successfully developed a new DGT passive sampler for reliable in situ time-integrated measurements of PAHs in waters at the ng/L level. This is the first time to use passive samplers for accurate measurements of hydrophobic organic contaminants in aquatic systems without calibration, a big step forward in monitoring PAHs. The application of this new sampler will enhance our understanding of the sources, fate, behavior and ecotoxicology of PAHs, enabling improved environmental risk assessment and management of these compounds.
引用
收藏
页数:10
相关论文
共 57 条
  • [1] Photodegradation of PAHs in passive water samplers
    Allan, Ian J.
    Christensen, Guttorm
    Baek, Kine
    Evenset, Anita
    [J]. MARINE POLLUTION BULLETIN, 2016, 105 (01) : 249 - 254
  • [2] Balmer Jennifer E., 2019, Emerging Contaminants, V5, P128, DOI 10.1016/j.emcon.2019.04.002
  • [3] Passive sampling of wastewater as a tool for the long-term monitoring of community exposure: Illicit and prescription drug trends as a proof of concept
    Baz-Lomba, J. A.
    Harman, Christopher
    Reid, Malcolm
    Thomas, Kevin V.
    [J]. WATER RESEARCH, 2017, 121 : 221 - 230
  • [4] Passive sampling of nonpolar contaminants at three deep-ocean sites
    Booij, Kees
    van Bommel, Ronald
    van Aken, Hendrik M.
    van Haren, Hans
    Brummer, Geert-Jan A.
    Ridderinkhof, Herman
    [J]. ENVIRONMENTAL POLLUTION, 2014, 195 : 101 - 108
  • [5] Time-integrated monitoring of polycyclic aromatic hydrocarbons (PAHs) in groundwater using the Ceramic Dosimeter passive sampling device
    Bopp, S
    Weiss, H
    Schirmer, K
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1072 (01) : 137 - 147
  • [6] Development and Calibration of an Organic-Diffusive Gradients in Thin Films Aquatic Passive Sampler for a Diverse Suite of Polar Organic Contaminants
    Challis, Jonathan K.
    Hanson, Mark L.
    Wong, Charles S.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (21) : 10583 - 10591
  • [7] The effects of flow rate and temperature on SPMD measurements of bioavailable PAHs in seawater
    Chang, Wan-Ting
    Lee, Chon-Lin
    Brimblecombe, Peter
    Fang, Meng-Der
    Chang, Kuo-Tung
    Liu, James T.
    [J]. MARINE POLLUTION BULLETIN, 2015, 97 (1-2) : 217 - 223
  • [8] Evidence and Recommendations to Support the Use of a Novel Passive Water Sampler to Quantify Antibiotics in Wastewaters
    Chen, Chang-Er
    Zhang, Hao
    Ying, Guang-Guo
    Jones, Kevin C.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (23) : 13587 - 13593
  • [9] A novel passive water sampler for in situ sampling of antibiotics
    Chen, Chang-Er
    Zhang, Hao
    Jones, Kevin C.
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2012, 14 (06): : 1523 - 1530
  • [10] DGT Passive Sampling for Quantitative in Situ Measurements of Compounds from Household and Personal Care Products in Waters
    Chen, Wei
    Li, Yanying
    Chen, Chang-Er
    Sweetman, Andrew J.
    Zhang, Hao
    Jones, Kevin C.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (22) : 13274 - 13281