Exploring the Potential of a Novel Iodine-Based Material as an Alternative Contrast Agent in X-ray Imaging Studies

被引:0
作者
Bliznakova, Kristina [1 ]
Kolev, Iliyan [2 ]
Dukov, Nikolay [1 ]
Dimova, Tanya [2 ]
Bliznakov, Zhivko [1 ]
机构
[1] Med Univ Varna, Fac Publ Hlth, Dept Med Equipment Elect & Informat Technol Health, Varna 9002, Bulgaria
[2] Med Univ Varna, Fac Pharm, Dept Pharmaceut Chem, Varna, Bulgaria
关键词
radiocontrast agent; X-ray imaging; physical phantoms; simulations; ENHANCED SPECTRAL MAMMOGRAPHY; BREAST; OPTIMIZATION; SUBTRACTION; PHANTOMS;
D O I
10.3390/ma17092059
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Background: Contrast-enhanced mammography is one of the new emerging imaging techniques used for detecting breast tissue lesions. Optimization of imaging protocols and reconstruction techniques for this modality, however, requires the involvement of physical phantoms. Their development is related to the use of radiocontrast agents. This study assesses the X-ray properties of a novel contrast material in clinical settings. This material is intended for experimental use with physical phantoms, offering an alternative to commonly available radiocontrast agents. Materials and Methods: The water-soluble sodium salt of the newly synthesized diiodine-substituted natural eudesmic acid, Sodium 2,6-DiIodo-3,4,5-TriMethoxyBenzoate [NaDITMB], has been investigated with respect to one of the most commonly applied radiocontrast medium in medical practice-Omnipaque (R). For this purpose, simulation and experimental studies were carried out with a computational phantom and a physical counterpart, respectively. Synthetic and experimental X-ray images were subsequently produced under varying beam kilovoltage peaks (kVps), and the proposed contrast material was evaluated. Results and Discussion: Simulation results revealed equivalent absorptions between the two simulated radiocontrast agents. Experimental findings supported these simulations, showing a maximum deviation of 3.7% between the image gray values of contrast materials for NaDITMB and Omnipaque solutions for a 46 kVp X-ray beam. Higher kVp X-ray beams show even smaller deviations in the mean grey values of the imaged contrast agents, with the NaDITMB solution demonstrating less than a 2% deviation compared to Omnipaque. Conclusion: The proposed contrast agent is a suitable candidate for use in experimental work related to contrast-enhanced imaging by utilizing phantoms. It boasts the advantages of easy synthesis and is recognized for its safety, ensuring a secure environment for both the experimenter and the environment.
引用
收藏
页数:13
相关论文
共 38 条
[1]   Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent [J].
Amato, Carlo ;
Susenburger, Markus ;
Lehr, Samuel ;
Kuntz, Jan ;
Gehrke, Nicole ;
Franke, Danielle ;
Thuering, Thomas ;
Briel, Andreas ;
Broennimann, Christian ;
Kachelriess, Marc ;
Sawall, Stefan .
PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (13)
[2]   Potential of contrast agents based on high-Z elements for contrast-enhanced photon-counting computed tomography [J].
Amato, Carlo ;
Klein, Laura ;
Wehrse, Eckhard ;
Rotkopf, Lukas T. ;
Sawall, Stefan ;
Maier, Joscha ;
Ziener, Christian H. ;
Schlemmer, Heinz-Peter ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2020, 47 (12) :6179-6190
[3]  
Aminu AJ., 2022, Translational Res. Anat, V27, P100175, DOI [10.1016/j.tria.2022.100175, DOI 10.1016/J.TRIA.2022.100175]
[4]   Evaluation of the minimum iodine concentration for contrast-enhanced subtraction mammography [J].
Baldelli, P. ;
Bravin, A. ;
Di Maggio, C. ;
Gennaro, G. ;
Sarnelli, A. ;
Taibi, A. ;
Gambaccini, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (17) :4233-4251
[5]   Evaluation of an improved algorithm for producing realistic 3D breast software phantoms: Application for mammography [J].
Bliznakova, K. ;
Suryanarayanan, S. ;
Karellas, A. ;
Pallikarakis, N. .
MEDICAL PHYSICS, 2010, 37 (11) :5604-5617
[6]   Experimental validation of a radiographic simulation code using breast phantom for X-ray imaging [J].
Bliznakova, K. ;
Speller, R. ;
Horrocks, J. ;
Liaparinos, P. ;
Kolitsi, Z. ;
Pallikarakis, N. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2010, 40 (02) :208-214
[7]   The advent of anthropomorphic three-dimensional breast phantoms for X-ray imaging [J].
Bliznakova, Kristina .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 :145-161
[8]   Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV [J].
Boone, JM ;
Seibert, JA .
MEDICAL PHYSICS, 1997, 24 (11) :1661-1670
[9]   State of art and optimization perspectives for breast imaging [J].
Calandrino, Riccardo ;
Loria, Alessandro ;
Panizza, Pietro ;
Taibi, Angelo ;
del Vecchio, Antonella .
PHYSICS OPEN, 2021, 7
[10]   X-ray spectra and gamma factors from 70 to 120 kV X-ray tube voltages [J].
Campillo-Rivera, Guillermo Eduardo ;
Torres-Cortes, Carina Oliva ;
Vazquez-Banuelos, Joel ;
Garcia-Reyna, Mayra Guadalupe ;
Marquez-Mata, Claudia Angelica ;
Vasquez-Arteaga, Marcial ;
Vega-Carrillo, Hector Rene .
RADIATION PHYSICS AND CHEMISTRY, 2021, 184