Evaluation of Automated Mammographic Density Classification in Tomosynthesis: Comparison with Radiologists

被引:0
|
作者
Kiziloglu, Hueseyin Alper [1 ]
Beyhan, Murat [1 ]
Gokce, Erkan [1 ]
Birisik, Yasar [1 ]
Battal, Muhammet Furkan [1 ]
Ceker, Muhammed Erkam [1 ]
Demir, Osman [2 ]
机构
[1] Tokat Gaziosmanpasa Univ, Fac Med, Dept Radiol, Kaleardi Neighborhood Muhittin Fisunoglu St, TR-60250 Tokat, Turkiye
[2] Tokat Gaziosmanpasa Univ, Fac Med, Dept Biostat, Tokat, Turkiye
来源
EUROPEAN JOURNAL OF THERAPEUTICS | 2024年 / 30卷 / 03期
关键词
Bellus software; mammographic density; automatic; BREAST DENSITY; 5TH EDITION; VARIABILITY; WOMEN;
D O I
10.58600/eurjther2002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Breast cancer screening is a valuable field of health research conducted through mammography. However, mammography evaluation is the examination with the most frequent lack of to agrement among radiologists. In this study we aimed to show the compatibility of mammographic density classification with a new software, Bellus Breast Density Measurement Software (Option), with visual examination. Methods: The mammographic density classification of 500 patients was retrospectively determined by five radiologists with varying levels of experience, according to the 5th version of the breast imaging reporting and data system (BIRADS). The mean age of 500 women included in the study was calculated as 53.8 +/- 10.08. The obtained data were compared with the Bellus software mammographic density classification of the same patients. Then, the visual evaluation and the compatibility of the Bellus software and the readers were compared. Results: The agreement between the Bellus software and all five readers was poor (kappa value 0.07-0.12). The agreement of the readers with each other is moderate-good (kappa value 0.0540.64). The Intraclass Correlation Coeffi cient (ICC) value for the five separate readers was calculated to be 0.80, indicating good compatibility, while the ICC value for the Bellus software with the five separate readers was calculated to be 0.74, indicating moderate compatibility. The Friedman test revealed that while the mammographic density classification of each reader remained consistent, the classification provided by the Bellus software differed. Conclusion: Bellus Breast Density Measurement Software (Option) diagnostic accuracy is lower than visual examination. We recommend that the manufacturer develop the software.
引用
收藏
页码:258 / 266
页数:9
相关论文
共 50 条
  • [41] Fully Automated Volumetric Breast Density Estimation from Digital Breast Tomosynthesis
    Gastounioti, Aimilia
    Pantalone, Lauren
    Scott, Christopher G.
    Cohen, Eric A.
    Wu, Fang F.
    Winham, Stacey J.
    Jensen, Matthew R.
    Maidment, Andrew D. A.
    Vachon, Celine M.
    Conant, Emily F.
    Kontos, Despina
    RADIOLOGY, 2021, 301 (03) : 561 - 568
  • [42] Inter-observer variability in mammographic density assessment using Royal Australian and New Zealand College of Radiologists (RANZCR) synoptic scales
    Damases, Christine N.
    Mello-Thoms, Claudia
    McEntee, Mark F.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (03) : 329 - 336
  • [43] Automated mammographic density measurement using Quantra™: comparison with the Royal Australian and New Zealand College of Radiology synoptic scale
    Yeo, Inez
    Akwo, Judith
    Ekpo, Ernest
    JOURNAL OF MEDICAL IMAGING, 2020, 7 (03)
  • [44] Multi-View Mammographic Density Classification by Dilated and Attention-Guided Residual Learning
    Li, Cheng
    Xu, Jingxu
    Liu, Qiegen
    Zhou, Yongjin
    Mou, Lisha
    Pu, Zuhui
    Xia, Yong
    Zheng, Hairong
    Wang, Shanshan
    IEEE-ACM TRANSACTIONS ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2021, 18 (03) : 1003 - 1013
  • [45] Evaluation of the association of endometriosis and mammographic breast density, a cross-sectional study
    Moini, Ashraf
    Salari, Elnaz
    Rashidi, Hadi
    Maajani, Khadije
    Abedi, Mahboubeh
    Bayani, Leila
    Alipour, Sadaf
    BMC WOMENS HEALTH, 2022, 22 (01)
  • [46] Mammographic Density Assessment by Artificial Intelligence-Based Computer-Assisted Diagnosis: A Comparison with Automated Volumetric Assessment
    Si Eun Lee
    Nak-Hoon Son
    Myung Hyun Kim
    Eun-Kyung Kim
    Journal of Digital Imaging, 2022, 35 : 173 - 179
  • [47] Classification of mammographic breast density by the histogram approach using neural networks
    Goto, S
    Azuma, Y
    Sumimoto, T
    Eiho, S
    FIFTH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND CONTROL TECHNOLOGY, 2003, 5253 : 508 - 511
  • [48] MAMMOGRAPHIC DENSITY ESTIMATION AND CLASSIFICATION USING SEGMENTATION AND PROGRESSIVE ELIMINATION METHOD
    Maitra, Indra Kanta
    Nag, Sanjay
    Bandyopadhyay, Samir K.
    INTERNATIONAL JOURNAL OF IMAGE AND GRAPHICS, 2013, 13 (03)
  • [49] Multi-Path Deep Learning Model for Automated Mammographic Density Categorization
    Ma, Xiangyuan
    Fisher, Caleb
    Wei, Jun
    Helvie, Mark A.
    Chan, Heang-Ping
    Zhou, Chuan
    Hadjiiski, Lubomir
    Lu, Yao
    MEDICAL IMAGING 2019: COMPUTER-AIDED DIAGNOSIS, 2019, 10950
  • [50] Design and clinical validation of a software program for automated measurement of mammographic breast density
    Adriano L. C. Araújo
    Heliana B. Soares
    Daniel F. Carvalho
    Roberto M. Mendonça
    Antonio G. Oliveira
    BMC Medical Informatics and Decision Making, 20