A new designed full process coverage robot-assisted total hip arthroplasty: a multicentre randomized clinical trial

被引:9
作者
Lu, Xinzhe [1 ]
Zhang, Zian [1 ]
Xu, Hao [1 ]
Wang, Wenzhe [1 ]
Zhang, Haining [1 ]
机构
[1] Qingdao Univ, Affiliated Hosp, Dept Joint Surg, Qingdao 266100, Shandong, Peoples R China
关键词
Multicenter clinical study; randomized controlled trial; robot-assisted total hip arthroplasty; FEMORAL COMPONENT VERSION; ANTEVERSION; DISLOCATION; POSITION; PLACEMENT; MINIMUM; RISK; THA;
D O I
10.1097/JS9.0000000000001103
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare the effect of a new complete robot-assisted total hip arthroplasty (RA-THA) with that of the manual total hip arthroplasty (MTHA) and to verify the accuracy and safety of the former. Methods: Overall, 148 patients were enroled from 3 March 2021 to 28 December 2021 in this study and classified into RA-THA (n=74 patients) and MTHA (n=74 patients) groups. The sex, age, operative side, BMI, diagnosis, other basic information, operative time, acetabular prosthesis anteversion and inclination, femoral prosthesis anteversion and angulation, femoral prosthesis filling rate, leg length discrepancy (LLD), Harris hip score, and visual analogue scale (VAS) score of the two groups were compared. Results: No significant differences were observed in the two groups regarding sex, age, operative side, BMI, diagnosis, Harris hip score, VAS score, acetabular inclination, acetabular prosthesis anteversion, femoral prosthesis anteversion, combined anteversion, and femoral prosthesis filling rate (P>0.05). The operative time was significantly longer in the RA-THA group than in the MTHA group (106.71 +/- 25.22 min vs. 79.42 +/- 16.16 min; t=7.30, P<0.05). The femoral angulation (1.78 degrees +/- 0.64 degrees) and LLD (2.87 +/- 1.55 mm) in the RA-THA group were significantly lesser than those in the MTHA group (2.22 degrees +/- 1.11 degrees and 5.81 +/- 6.27 mm, respectively; t=-2.95 and t=-3.88, P<0.05). Conclusion: The complete RA-THA has some advantages over the traditional procedure in restoring the lower limb length and controlling the femoral prosthesis angulation. Thus, this study verifies the accuracy and safety of the robot-assisted system.
引用
收藏
页码:2141 / 2150
页数:10
相关论文
共 36 条
[21]   Differences in femoral component subsidence rate after THA using an uncemented collarless femoral stem: full weight-bearing with an enhanced recovery rehabilitation versus partial weight-bearing [J].
Leiss, Franziska ;
Goetz, Julia Sabrina ;
Meyer, Matthias ;
Maderbacher, Gunther ;
Reinhard, Jan ;
Parik, Lukas ;
Grifka, Joachim ;
Greimel, Felix .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (04) :673-680
[22]   DISLOCATIONS AFTER TOTAL HIP-REPLACEMENT ARTHROPLASTIES [J].
LEWINNEK, GE ;
LEWIS, JL ;
TARR, R ;
COMPERE, CL ;
ZIMMERMAN, JR .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (02) :217-220
[23]   Evaluation of Native Femoral Neck Version and Final Stem Version Variability in Patients With Osteoarthritis Undergoing Robotically Implanted Total Hip Arthroplasty [J].
Marcovigi, Andrea ;
Ciampalini, Luigi ;
Perazzini, Piergiuseppe ;
Caldora, Patrizio ;
Grandi, Gianluca ;
Catani, Fabio .
JOURNAL OF ARTHROPLASTY, 2019, 34 (01) :108-115
[24]   The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA [J].
Murphy, William S. ;
Yun, Ho Hyun ;
Hayden, Brett ;
Kowal, Jens H. ;
Murphy, Stephen B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (02) :325-335
[25]   Intraoperative placement of total hip arthroplasty components with robotic-arm assisted technology correlates with postoperative implant position A CT-BASED STUDY [J].
Nodzo, S. R. ;
Chang, C-C ;
Carroll, K. M. ;
Barlow, B. T. ;
Banks, S. A. ;
Padgett, D. E. ;
Mayman, D. J. ;
Jerabek, S. A. .
BONE & JOINT JOURNAL, 2018, 100B (10) :1303-1309
[26]   Robot-assisted total hip arthroplasty: Clinical outcomes and complication rate [J].
Perets, Itay ;
Walsh, John P. ;
Close, Mary R. ;
Mu, Brian H. ;
Yuen, Leslie C. ;
Domb, Benjamin G. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2018, 14 (04)
[27]   Direct Anterior Approach for Total Hip Arthroplasty: Indications, Technique, and Results [J].
Post, Zachary D. ;
Orozco, Fabio ;
Diaz-Ledezma, Claudio ;
Hozack, William J. ;
Ong, Alvin .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2014, 22 (09) :595-603
[28]   Correction of limb-length inequality during total hip arthroplasty [J].
Ranawat, CS ;
Rao, RR ;
Rodriguez, JA ;
Bhende, HS .
JOURNAL OF ARTHROPLASTY, 2001, 16 (06) :715-720
[29]   Prevention of Dislocation After Total Hip Arthroplasty [J].
Rowan, Fiachra E. ;
Benjamin, Biju ;
Pietrak, Jurek R. ;
Haddad, Fares S. .
JOURNAL OF ARTHROPLASTY, 2018, 33 (05) :1316-1324
[30]   Accuracy of Computer Navigation for Acetabular Component Placement in THA [J].
Ryan, James A. ;
Jamali, Amir A. ;
Bargar, William L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (01) :169-177